Seth Michel Pantanelli

Dr. Seth Michel Pantanelli

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2007 in Ophthalmology
Verified
Journal Article
Closed access
SPSeth Michel Pantanelli
Seth Michel Pantanelli
SMScott MacRae
Scott MacRae
TJTae Moon Jeong
Tae Moon Jeong
GYGeunyoung Yoon
Geunyoung Yoon

1 May 2020 in JAMA Ophthalmology
Verified
Journal Article
Open access
PDF file
MCMona L. Camacci
Mona L. Camacci
ALAmy Lu
Amy Lu
ELErik B. Lehman
Erik B. Lehman
ISIngrid U. Scott
Ingrid U. Scott
EBEsther Bowie
Esther Bowie
SPSeth Michel Pantanelli
Seth Michel Pantanelli
Women physicians face a unique set of challenges within the medical field, ranging from subconscious and implicit bias to sex disparities in pay and promotion to leadership positions. Understanding the role that sex inequality plays within the field of ophthalmology is essential to changing the current landscape.

1 March 2008 in Journal of Biological Chemistry
Verified
Journal Article
Open access
PDF file
BLBaoying Liu
Baoying Liu
ZLZhuqing Li
Zhuqing Li
SMSankaranarayana P. Mahesh
Sankaranarayana P. Mahesh
SPSeth Michel Pantanelli
Seth Michel Pantanelli
FHFrank S. Hwang
Frank S. Hwang
RNRobert B. Nussenblatt
Robert B. Nussenblatt
Glucocorticoid-induced tumor necrosis factor receptor (GITR), found constitutively expressed on human primary natural killer (NK) cells at low levels was up-regulated upon stimulation by either Toll-like receptor ligand or NK cell growth factor, interleukin (IL)-15. cDNA microarray analysis showed that engagement of GITR primarily suppressed the activation of NF-KB pathway of NK cells and up-regulated anti-inflammatory genes heme oxygenase-1 and IL-10. Further analysis revealed that GITR activation suppressed NK cell proliferation in response to IL-15. GITR activation also suppressed proinflammatory cytokine secretion and increased NK cell apoptosis. GITR activation resulted in blocked phosphorylation of Stat5 and Akt, which may have contributed to the observed antiproliferative effect of GITR on NK cells. Increased apoptosis was independent of the Fas-FasL pathway, but Bcl-XL and phospho-Bad protein expressions were diminished, suggesting involvement of the mitochondrial apoptosis pathway. The results suggest that although GITR is an activation marker for NK cells similar to that for T cells, GITR serves as a negative regulator for NK cell activation. Our studies demonstrate a novel physiological role of GITR on NK cells.

1 April 2017 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
DHDarren C. Hill
Darren C. Hill
SSShruti Sudhakar
Shruti Sudhakar
CHChristopher S. Hill
Christopher S. Hill
TKTonya S. King
Tonya S. King
ISIngrid U. Scott
Ingrid U. Scott
SPSeth Michel Pantanelli
Seth Michel Pantanelli
To compare the accuracy of intraoperative wavefront aberrometry (ORA) and the Hill-radial basis function (RBF) formula with other formulas based on preoperative biometry in predicting residual refractive error after cataract surgery in eyes with axial myopia. Private practice, Harrisburg, Pennsylvania, USA. Retrospective consecutive case series. Eyes with an axial length (AL) greater than 25.0 mm had cataract extraction with intraocular lens implantation. For each eye, the 1-center Wang-Koch AL-optimized Holladay 1 formula was used to select an IOL targeting emmetropia. Residual refractive error was predicted preoperatively using the SRK/T, Holladay 1 and 2, Barrett Universal II, and Hill-RBF formulas and intraoperatively using wavefront aberrometry. The postoperative refraction was compared with the preoperative and intraoperative predictions. The study comprised 37 patients (51 eyes). The mean numerical errors ± standard error associated with using the SRK/T, Holladay 1, AL-optimized Holladay 1, Holladay 2, Barrett Universal II, and Hill-RBF formulas and intraoperative wavefront aberrometry were 0.20 ± 0.06 diopters (D), 0.33 ± 0.06 D, -0.02 ± 0.06 D, 0.24 ± 0.06 D, 0.19 ± 0.06 D, 0.22 ± 0.06 D, and 0.056 ± 0.06 D, respectively (P < .001). The proportion of patients within ±0.5 D of the predicted error was 74.5%, 62.8%, 82.4%, 79.1%, 73.9%, 76.7%, and 80.4%, respectively (P = .090). Hyperopic outcomes occurred in 70.6%, 76.5%, 49.0%, 74.4%, 76.1%, 74.4%, and 45.1% of the eyes, respectively (P = .007). Intraoperative wavefront aberrometry was better than all formulas based on preoperative biometry and as effective as the AL-optimized Holladay 1 formula in predicting residual refractive error and reducing hyperopic outcomes. The Hill-RBF formula's performance was similar to that of the fourth-generation formulas.

1 April 2009 in Archives of Ophthalmology (1950)
Verified
Journal Article
Open access
PDF file
SYSteven Yeh
Steven Yeh
ZLZhuqing Li
Zhuqing Li
FFFarzin Forooghian
Farzin Forooghian
FHFrank S. Hwang
Frank S. Hwang
MCMatthew A. Cunningham
Matthew A. Cunningham
RNRobert B. Nussenblatt
Robert B. Nussenblatt
Uveitis has been reported to contribute to the cause of up to 10% of cases of blindness in developed nations and may result in significant visual handicap in untreated patients.1 A recent report suggested that uveitis occurs with an incidence of 52 in 100 000 person-years, with a prevalence of 115 in 100 000 persons.2 Because of the significant impact of uveitis on visual disability and blindness, investigation of the basic mechanisms underlying ocular inflammation is warranted.

1 January 2006 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
GYGeunyoung Yoon
Geunyoung Yoon
SPSeth Michel Pantanelli
Seth Michel Pantanelli
LNLana J. Nagy
Lana J. Nagy
A conventional Shack-Hartmann wavefront sensor has a limitation that increasing the dynamic range usually requires sacrificing measurement sensitivity. The prototype large-dynamic-range Shack-Hartmann wavefront sensor presented resolves this problem by using a translatable plate with subapertures placed in conjugate with the lenslet array. Each subaperture is the same size as a lenslet and they are arranged so that they overlap every other lenslet position. Three translations of the plate are required to acquire four images to complete one measurement. This method increases the dynamic range by a factor of two with no subsequent change in measurement sensitivity and sampling resolution of the aberration. The feasibility of the sensor was demonstrated by measuring the higher order aberrations of a custom-made phase plate and human eyes with and without the plate.