Xing Fu

Dr. Xing Fu

Faculty of Infrastructural Engineering, Dalian University of Technology, Dalian, China
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2018 in Structural Control and Health Monitoring
Verified
Journal Article
Closed access
PDF file
Hong-Nan LiHong-Nan Li
Hong-Nan Li
ZHZhou Huang
Zhou Huang
Xing FuXing Fu
Xing Fu
GLGang Li
Gang Li

27 February 2020 in Advances in Structural Engineering
Verified
Journal Article
Closed access
PDF file
LTLi Tian
Li Tian
XZXin Zhang
Xin Zhang
Xing FuXing Fu
Xing Fu
Numerous transmission towers have collapsed due to experiencing strong winds; therefore, the purpose of this article is to investigate the collapse mechanism and the anti-collapse performance of a long-span transmission tower–line system. The detailed finite element model of a typical tower–line system is established in ABAQUS. A global damage index is proposed to quantitatively estimate the overall damage of the structure and define the collapse criteria. An incremental dynamic analysis is performed to obtain the collapse mechanism and the ultimate capacity of the structure. Subsequently, a fragility analysis for evaluating the anti-collapse performance is conducted due to the uncertainty of wind loads. Eventually, the influence of the wind attack angle and the length of the side spans on the fragility is discussed. The results demonstrate that the proposed global damage index is capable of quantitatively reflecting the overall damage and assessing the ultimate capacity of the structure. In addition, the uncertainty of the wind load has a significant influence on the ultimate capacity and the failure position. Furthermore, the results reveal that the wind attack angle and the length of the side spans have an apparent effect on the fragility of the structure.

8 June 2018 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
HLHong-Nan Li
Hong-Nan Li
MLMing-Ming Liu
Ming-Ming Liu
Xing FuXing Fu
Xing Fu
In this paper, an innovative re-centering damper is presented to reduce the residual deflection of civil structures under strong earthquakes. The schematic diagram of the proposed re-centering SMA-lead damper (RSLD) is provided first. Then the mechanical behaviors of all the sub-components are measured by the testing machine, followed by the proposal of mechanical model of the RSLD. Based on the experimental results, the mechanical model factors for each sub-component are determined by the data fitting method, which is then used to simulate the hysteresis loops of the damper. Meanwhile the experiment of the fabricated RSLD is carried out to study the influence of the loading rate and displacement amplitude on the mechanical properties. Finally, the response analysis of a six-story steel frame structure installed with different damper position configurations is performed, and the results reveal that the proposed RSLD has an outstanding re-centering capacity.

1 June 2020 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
Li TianLi Tian
Li Tian
XZXin Zhang
Xin Zhang
Xing FuXing Fu
Xing Fu
Given the premise that a communication tower is a vital infrastructure that may collapse when encountering a wind disaster, this paper focused on investigating the collapse mechanism and collapse fragility of a communication tower subjected to wind loads. In this paper, a finite-element (FE) model of a 60-m-tall communication tower that collapsed under wind loads was created in ABAQUS (version 6.10). The wind-induced response was studied considering member buckling, and the Tian-Ma-Qu material model was used. Based on the dynamic explicit method, collapse simulations of the tower were performed with different wind attack angles using the incremental dynamic analysis (IDA) method. Subsequently, the weak position and the collapse mechanism of the tower were summarized. The results indicated that the Tian-Ma-Qu material model was effective in simulating the collapse of communication towers; the buckling of the main members was the governing reason for the progressive collapse of the tower. Thus, the main members should be strengthened in the design. Furthermore, the collapse fragility analysis of the tower was investigated, and the influence of the wind attack angle was discussed. The results demonstrated that the wind attack angle had a significant impact on the collapse fragility curve and the ultimate capacity.

26 July 2020 in Structural Control and Health Monitoring
Verified
Journal Article
Closed access
PDF file
Hong-Nan LiHong-Nan Li
Hong-Nan Li
ZHZhou Huang
Zhou Huang
Xing FuXing Fu
Xing Fu

6 January 2020 in Advances in Structural Engineering
Verified
Journal Article
Closed access
PDF file
HLHong-Nan Li
Hong-Nan Li
JWJin-Xin Wang
Jin-Xin Wang
Xing FuXing Fu
Xing Fu
LRLiang Ren
Liang Ren
QZQing Zhang
Qing Zhang
Many transmission towers have collapsed under typhoons in recent years, mainly due to the unclear behaviors of their structural properties, introducing many deficiencies in the design process. Therefore, implementing structural health monitoring is of great importance for investigating the structural features of large-span transmission lines. This study develops a stochastic subspace identification method to identify the modal parameters of transmission towers, and a finite element model of a transmission tower-line system is established based on a case in Guangdong Province, China. Moreover, a MATLAB program is written using the stochastic subspace identification method to perform a modal analysis on the wind-induced responses of a transmission tower, and the results are compared with those of the finite element model to verify the program’s reliability. A structural health monitoring system installed on a transmission tower recorded the wind field data around the tower and its vibration responses during Typhoon Khanun. The characteristics of the typhoon wind field and the changes in the acceleration responses under different wind speeds were calculated, and the developed stochastic subspace identification method was used to identify the frequencies and damping ratios of the tower. The results show that the identified frequencies under different wind speeds in the longitudinal and transverse directions remain essentially unchanged, indicating that the monitoring tower was safe and suffered no damage during Typhoon Khanun. The damping ratios of the monitoring tower range from 1% to 4%, where the larger values may be caused by bolt slippage.