Artis Knapsis

Dr. Artis Knapsis

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2025 in Journal of Vascular Surgery
Verified
Journal Article
Open access
AIAbdulhakim Ibrahim
Abdulhakim Ibrahim
Artis KnapsisArtis Knapsis
Artis Knapsis
HSHubert Schelzig
Hubert Schelzig
TTTong Trinh
Tong Trinh
PSPhilipp Schminke
Philipp Schminke
AOAlexander Oberhuber
Alexander Oberhuber
The purpose of our multicenter study was to compare the outcome (left subclavian artery [LSA] patency and reintervention) of carotid-subclavian bypass (distal anastomosis supraclavicular) vs carotid-axillary bypass (distal anastomosis infraclavicular), as well as analyzing and comparing possible complications such as phrenic nerve injury and lymph leakage. This multicenter retrospective, observational study included a total of 238 patients who underwent open procedures involving the carotid-axillary bypass (CA) (n = 51) or carotid-subclavian bypass (CB) (n = 187) between January 2011 and December 2022. The mean age of the patients was 64.2 ± 0.8 years (CA, 64.9 ± 1.6 vs CS, 64.07± 0.9). The mean follow-up was 19.4 ± 2.4 months. The most common diagnosis for open LSA revascularization was debranching owing to landing zone preparation during thoracic endovascular aortic repair for aortic aneurysm (n = 100 [42%]) and aortic dissection (n = 81 [34%]). Forty patients (16.8%) were operated owing to a symptomatic occlusion of the subclavian artery. Postoperative complications such as stroke, laryngeal nerve palsy, myocardial infarct, in-hospital mortality, and 30-day bypass occlusion did not differ between the groups. Only patients with the CS experienced postoperative phrenic nerve injury (P = .002) and lymphatic leakage (P = .039). A comparison of bypass-related reintervention between the patients showed no significant difference between the groups (P = .735). The open surgical revascularization of LSA using the axillary artery as the distal bypass target is a safe alternative to traditional CS. It requires a more superficial approach and reduces the incidence of well-known complications such as phrenic nerve affection and lymphatic leakage.

14 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JMJoscha Mulorz
Joscha Mulorz
FGFranziska Garcon
Franziska Garcon
AAAmir Arnautovic
Amir Arnautovic
CSCasper De Somer
Casper De Somer
Artis KnapsisArtis Knapsis
Artis Knapsis
MWMarkus Udo Wagenhäuser
Markus Udo Wagenhäuser
Objective: The incidence of type B aortic dissection (TBAD) is increasing worldwide; however, the underlying pathomechanisms are not conclusively understood. This study explores the geometric architecture of the aortic arch and supra-aortic branches in TBAD patients as opposed to non-TBAD patients. Methods: Patient characteristics were retrieved from archived medical records. Computer-assisted tomography (CAT) scans of patients with TBAD and carotid stenosis (CS) from two high-volume centers were analyzed. Various aortic arch parameters and take-off angles of the supra-aortic branches of TBAD patients were measured following centerline normalization in comparison CS patients. A compression index (C-index) was calculated from the para-sagittal, and a torsion index (T-index) was calculated from the para-coronal take-off angles of the supra-aortic branches to analyze aortic arch tortuosity. Results: A total of 199 CAT scans were analyzed, namely, 85 in the TBAD group and 114 in the CS group. The average age was 61.5 ± 13.1 years among the TBAD patients and 71 ± 9.3 years among the CS patients. We found a significantly higher proportion of type III aortic arch configurations in TBAD patients compared with CS patients. Further, the aortic arch angle was steeper in the TBAD group. In the para-sagittal plane, the left subclavian artery (LSA) take-off angle was less steep in TBAD patients. In the para-coronal plane, the left carotid artery (LCA) had a less steep take-off angle, while the LSA had a more obtuse take-off angle in the TBAD group when compared with the CS group. In addition, the inter-vessel distance was increased in TBAD patients. Finally, the T-index was increased, suggesting a significant torsion resulting from the deviating take-off angles of the supra-aortic branches supplying the left half of the body as opposed to the innominate artery (IA) in TBAD patients. Conclusions: Our results suggest several aortic arch-specific geometric configurations in patients suffering from TBAD that significantly differ from those in CS patients. Further functional studies are needed to verify the pathogenetic relevance of our results and their disease-specific causality. Although our data are not mechanistically explorative, they may serve as a basis for identifying future patients with aortic arch morphology at higher risk for TBAD development and who may benefit from more stringent adjustment of risk factors as a primary prevention concept.

6 August 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Artis KnapsisArtis Knapsis
Artis Knapsis
MSMelik-Murathan Seker
Melik-Murathan Seker
HSHubert Schelzig
Hubert Schelzig
MWMarkus Udo Wagenhäuser
Markus Udo Wagenhäuser
Objectives: There are several endovascular treatment options to treat aortic arch and thoracic aortic pathologies with custom-made or surgeon-modified aortic stent grafts. This study seeks to assess endovascular treatment methods for aortic arch and thoracic aortic pathologies with no acceptable proximal landing zone for standard thoracic endovascular aortic repair (TEVAR), comparing different treatment methods and evaluating technical success, intraoperative parameters and short-term outcomes. Methods: All patients undergoing elective or emergency endovascular treatment of aortic arch and thoracic aortic pathologies, with no acceptable landing zone for standard TEVAR, between 1 January 2010 and 31 March 2024, at the University Hospital Düsseldorf, Germany were included. An acceptable landing zone was defined as a minimum of 2 cm for sufficient sealing. All patients were not suitable for open surgery. Patients were categorized by an endovascular treatment method for a comprehensive comparison of pre-, intra- and postoperative variables. IBM SPSS29 was used for data analysis. Results: The patient cohort comprised 21 patients, predominantly males (81%), with an average age of 70.9 ± 9 years with no acceptable proximal landing zone for standard TEVAR procedure. The most treated aortic pathologies were penetrating aortic ulcers and chronic post-dissection aneurysms. Patients were sub-grouped according to the applied procedure as follows: five patients with chimney thoracic endovascular aortic repair (chTEVAR), seven patients with in situ fenestrated thoracic endovascular aortic repair (isfTEVAR), six patients with custom-made fenestrated thoracic endovascular aortic repair (cmfTEVAR) and three patients with custom-made branched thoracic endovascular aortic repair (cmbTEVAR). Emergency procedures involved two patients. There were significant differences in the total procedure and fluoroscopy time, as well as in contrast agent usage among the treatment groups. cmfTEVAR had the shortest total procedure time, while chTEVAR exhibited the highest contrast agent usage. The overall mortality rate among all procedures was 9.5% (two patients) and 4.7% for elective procedures, respectively. Deaths were associated with either retrograde type A dissection or stent graft infection. Both patients were treated with chTEVAR. There was one minor and one major stroke; these patients were treated with isfTEVAR. No endoleak occurred during any procedure. The reintervention rate for chTEVAR was 20% and 0% for all other procedures during the in-hospital stay. The patients who were treated with cmfTEVAR had no complications, the shortest operating and fluoroscopy time, and less contrast agent was needed in comparison with other treatment methods. Conclusions: Complex endovascular procedures of the aortic arch with custom-made or surgeon-modified aortic stent grafts offer a safe solution, with acceptable complication rates for patients who are not suitable for open aortic arch repair. In terms of procedure-related parameters and complication rates, a custom-made fenestrated TEVAR is potentially advantageous compared to the other endovascular techniques.

26 February 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MWMax Wilkat
Max Wilkat
JLJulian Lommen
Julian Lommen
Majeed RanaMajeed Rana
Majeed Rana
NKNorbert R. Kübler
Norbert R. Kübler
TWTobias Wienemann
Tobias Wienemann
AAAmir Arnautovic
Amir Arnautovic
Introduction: The use of 3D-printed aortic models for the creation of surgeon-modified endoprostheses represents a promising avenue in aortic surgery. By focusing on the potential impact of sterilization on model integrity and geometry, this report sheds light on the suitability of these models for creating customized endoprostheses. The study presented here aimed to investigate the safety and viability of 3D-printed aortic models in the context of sterilization processes and subsequent remodeling. Methods: The study involved the fabrication of 3D-printed aortic models using patient-specific imaging data and established additive manufacturing techniques. Five identical aortic models of the same patient were printed. Two models were subjected to sterilization and two to disinfection using commonly employed methods, and one model remained untreated. The models were checked by in-house quality control for deformation (heat map analyses) after the sterilization and disinfection processes. Three models (sterilized, disinfected, and untreated) were sent for ex-house (Lufthansa Technik, AG, Materials Technologies and Central Laboratory Services, Hamburg, Germany) evaluation and subsequent quantification of possible structural changes using advanced imaging and measurement technologies (macroscopic and SEM/EDX examinations). After sterilization and disinfection, each aortic model underwent sterility checks. Results: Based on macroscopic and SEM/EDX examinations, distinct evidence of material alterations attributed to a treatment process, such as a cleaning procedure, was not identified on the three implants. Comparative material analyses conducted via the EDX technique yield consistent results for all three implants. Disinfected and sterilized models tested negative for common pathogens. Conclusions: The evaluation of 3D-printed aortic models’ safety after sterilization as well as their suitability for surgeon-modified endoprostheses is a critical step toward their clinical integration. By comprehensively assessing changes in model integrity and geometry after sterilization, this research has contributed to the broader understanding of the use of 3D-printed models for tailor-made endovascular solutions. As medical technologies continue to evolve, research endeavors such as this one can serve as a foundation for harnessing the full potential of 3D printing to advance patient-centered care in aortic surgery.

6 June 2019 in Allgemein- und Viszeralchirurgie up2date
Verified
Journal Article
Closed access
PDF file
Artis KnapsisArtis Knapsis
Artis Knapsis
HSHubert Schelzig
Hubert Schelzig
MWMarkus U. Wagenhäuser
Markus U. Wagenhäuser
Traumatische Gefäßverletzungen sind selten, können jedoch zu erheblicher Morbidität und Mortalität führen mit den Leitsymptomen Blutung und/oder Organ- oder Extremitätenischämie. Ursachen sind: penetrierendes Trauma überwiegend in Konfliktgebieten, stumpfe Verletzungen durch Verkehrsunfälle und Stürze oder iatrogene Schädigungen. Neben endovaskulären Verfahren sind konventionell offen-operative Versorgungsansätze weiterhin eine effektive Therapieoption.

12 October 2022 in Notaufnahme up2date
Verified
Journal Article
Closed access
PDF file
Artis KnapsisArtis Knapsis
Artis Knapsis
JRJulian-Dario Rembe
Julian-Dario Rembe
Die akute und kritische Beinischämie der unteren Extremitäten bei Patienten mit einer peripheren arteriellen Verschlusskrankheit ist ein Notfall und ist mit hoher Morbidität und Letalität verbunden. Sofortige Diagnosestellung und Therapieeinleitung sind entscheidend, um den Extremitätenverlust und lebensbedrohliche Organkomplikationen zu vermeiden. Article published online: 12 October 2022 © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany