Myung Yung Jeong

Myung Yung Jeong


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2010 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
XHXiaosu (Frank) Hu
Xiaosu (Frank) Hu
KHKeum-Shik Hong
Keum-Shik Hong
SGShuzhi Ge
Shuzhi Ge
MJMyung Yung Jeong
Myung Yung Jeong
Background: Near-infrared spectroscopy (NIRS) is a non-invasive neuroimaging technique that recently has been developed to measure the changes of cerebral blood oxygenation associated with brain activities. To date, for functional brain mapping applications, there is no standard on-line method for analysing NIRS data.Methods: In this paper, a novel on-line NIRS data analysis framework taking advantages of both the general linear model (GLM) and the Kalman estimator is devised. The Kalman estimator is used to update the GLM coefficients recursively, and one critical coefficient regarding brain activities is then passed to at-statistical test. Thet-statistical test result is used to update a topographic brain activation map. Meanwhile, a set of high-pass filters is plugged into the GLM to prevent very low-frequency noises, and an autoregressive (AR) model is used to prevent the temporal correlation caused by physiological noises in NIRS time series. A set of data recorded in finger tapping experiments is studied using the proposed framework.Results: The obtained results suggest that the method can effectively track the task related brain activation areas, and prevent the noise distortion in the estimation while the experiment is running. Thereby, the potential of the proposed method for real-time NIRS-based brain imaging was demonstrated.Conclusions: This paper presents a novel on-line approach for analysing NIRS data for functional brain mapping applications. This approach demonstrates the potential of a real-time-updating topographic brain activation map.

23 September 2011 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
ATArjon Turnip
Arjon Turnip
KHKeum-Shik Hong
Keum-Shik Hong
MJMyung Yung Jeong
Myung Yung Jeong
The electroencephalography (EEG) signals are known to involve the firings of neurons in the brain. The P300 wave is a high potential caused by an event-related stimulus. The detection of P300s included in the measured EEG signals is widely investigated. The difficulties in detecting them are that they are mixed with other signals generated over a large brain area and their amplitudes are very small due to the distance and resistivity differences in their transmittance. A novel real-time feature extraction method for detecting P300 waves by combining an adaptive nonlinear principal component analysis (ANPCA) and a multilayer neural network is proposed. The measured EEG signals are first filtered using a sixth-order band-pass filter with cut-off frequencies of 1 Hz and 12 Hz. The proposed ANPCA scheme consists of four steps: pre-separation, whitening, separation, and estimation. In the experiment, four different inter-stimulus intervals (ISIs) are utilized: 325 ms, 350 ms, 375 ms, and 400 ms. The developed multi-stage principal component analysis method applied at the pre-separation step has reduced the external noises and artifacts significantly. The introduced adaptive law in the whitening step has made the subsequent algorithm in the separation step to converge fast. The separation performance index has varied from -20 dB to -33 dB due to randomness of source signals. The robustness of the ANPCA against background noises has been evaluated by comparing the separation performance indices of the ANPCA with four algorithms (NPCA, NSS-JD, JADE, and SOBI), in which the ANPCA algorithm demonstrated the shortest iteration time with performance index about 0.03. Upon this, it is asserted that the ANPCA algorithm successfully separates mixed source signals. The independent components produced from the observed data using the proposed method illustrated that the extracted signals were clearly the P300 components elicited by task-related stimuli. The experiment using 350 ms ISI showed the best performance. Since the proposed method does not use down-sampling and averaging, it can be used as a viable tool for real-time clinical applications.

9 June 2016 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
PDF file
MKMuhammad A. Kamran
Muhammad A. Kamran
MMMalik M. Naeem Mannan
Malik M. Naeem Mannan
MJMyung Yung Jeong
Myung Yung Jeong
Functional near-infrared spectroscopy (fNIRS) is a non-invasive neuroimaging modality that measures the concentration changes of oxy-hemoglobin (HbO) and de-oxy hemoglobin (HbR) at the same time. It is an emerging cortical imaging modality with a good temporal resolution that is acceptable for brain-computer interface applications. Researchers have developed several methods in last two decades to extract the neuronal activation related waveform from the observed fNIRS time series. But still there is no standard method for analysis of fNIRS data. This article presents a brief review of existing methodologies to model and analyze the activation signal. The purpose of this review article is to give a general overview of variety of existing methodologies to extract useful information from measured fNIRS data including pre-processing steps, effects of differential path length factor (DPF), variations and attributes of hemodynamic response function (HRF), extraction of evoked response, removal of physiological noises, instrumentation and environmental noises and resting/activation state functional connectivity. Finally, the challenges in the analysis of fNIRS signal are summarized.

7 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MMMalik Muhammad Naeem Mannan
Malik Muhammad Naeem Mannan
MKMuhammad Ahmad Kamran
Muhammad Ahmad Kamran
SKShinill Kang
Shinill Kang
Hak Soo ChoiHak Soo Choi
Hak Soo Choi
MJMyung Yung Jeong
Myung Yung Jeong
Steady-state visual evoked potentials (SSVEPs) have been extensively utilized to develop brain–computer interfaces (BCIs) due to the advantages of robustness, large number of commands, high classification accuracies, and information transfer rates (ITRs). However, the use of several simultaneous flickering stimuli often causes high levels of user discomfort, tiredness, annoyingness, and fatigue. Here we propose to design a stimuli-responsive hybrid speller by using electroencephalography (EEG) and video-based eye-tracking to increase user comfortability levels when presented with large numbers of simultaneously flickering stimuli. Interestingly, a canonical correlation analysis (CCA)-based framework was useful to identify target frequency with a 1 s duration of flickering signal. Our proposed BCI-speller uses only six frequencies to classify forty-eight targets, thus achieve greatly increased ITR, whereas basic SSVEP BCI-spellers use an equal number of frequencies to the number of targets. Using this speller, we obtained an average classification accuracy of 90.35 ± 3.597% with an average ITR of 184.06 ± 12.761 bits per minute in a cued-spelling task and an ITR of 190.73 ± 17.849 bits per minute in a free-spelling task. Consequently, our proposed speller is superior to the other spellers in terms of targets classified, classification accuracy, and ITR, while producing less fatigue, annoyingness, tiredness and discomfort. Together, our proposed hybrid eye tracking and SSVEP BCI-based system will ultimately enable a truly high-speed communication channel.

5 November 2019 in IEEE Access
Verified
Journal Article
Open access
MKMuhammad Ahmad Kamran
Muhammad Ahmad Kamran
MMMalik Muhammad Naeem Mannan
Malik Muhammad Naeem Mannan
MJMyung Yung Jeong
Myung Yung Jeong
Drowsiness/sleepiness is a serious issue that needs to be addressed for improvement in the safety of road driving. Past statistical data on road accidents has shown enormous increases in car crashes due to drowsy/sleepy feelings. This study comprehensively summarizes all aspects of the drowsy state and its effects during car driving: its symptoms, causes, presentation actions, car accident statistics, sleep stages, and the behavioral, physiological and neural activation changes occurring during wakefulness and in the drowsy state. It considers drivers’ behavioral data and corresponding methodologies for its analysis, the biomedical signals of the human body (including neuronal signals in the forms of electrical and hemodynamic responses), and their use for drowsiness detection. All of the existing methodologies, their uses and pros and cons, are comprehensively summarized. A detailed survey of the data published by neuro-imaging methodology-, physiological signal-and behavioral methodology-based studies in addition to studies using electro-mechanical installed sensors are statistically and theoretically summarized, as are the different approaches to the detection of drowsiness. Additionally, the neuronal activity occurring during the drowsy and awake states is analyzed, and the important contributions of fNIRS, fMRI and EEG in this context are discussed in detail. Differing existing drowsiness-detection systems installed in popular car brands also are reviewed. Finally, the remaining challenges and future suggestions for drowsiness-detection systems are summarized as well.

3 May 2016 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
PDF file
MMMalik M. Naeem Mannan
Malik M. Naeem Mannan
MJMyung Yung Jeong
Myung Yung Jeong
MKMuhammad A. Kamran
Muhammad A. Kamran
Electroencephalography (EEG) is a portable brain-imaging technique with the advantage of high-temporal resolution that can be used to record electrical activity of the brain. However, it is difficult to analyze EEG signals due to the contamination of ocular artifacts, and which potentially results in misleading conclusions. Also, it is a proven fact that the contamination of ocular artifacts cause to reduce the classification accuracy of a brain-computer interface (BCI). It is therefore very important to remove/reduce these artifacts before the analysis of EEG signals for applications like BCI. In this paper, a hybrid framework that combines independent component analysis (ICA), regression and high-order statistics has been proposed to identify and eliminate artifactual activities from EEG data. We used simulated, experimental and standard EEG signals to evaluate and analyze the effectiveness of the proposed method. Results demonstrate that the proposed method can effectively remove ocular artifacts as well as it can preserve the neuronal signals present in EEG data. A comparison with four methods from literature namely ICA, regression analysis, wavelet-ICA (wICA) and regression-ICA (REGICA) confirms the significantly enhanced performance and effectiveness of the proposed method for removal of ocular activities from EEG, in terms of lower mean square error and mean absolute error values and higher mutual information between reconstructed and original EEG.