Xiaoyi GUO

Dr. Xiaoyi GUO

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2024 in Water
Verified
Journal Article
Open access
PDF file
YWYongzhi Wang
Yongzhi Wang
ZXZhiheng Xu
Zhiheng Xu
YRYunlong Ran
Yunlong Ran
Xiaolei ZhangXiaolei Zhang
Xiaolei Zhang
XGXiaoyi GUO
Xiaoyi GUO
SLShuyu Liu
Shuyu Liu
The pressure characteristics of long-distance water pipelines during hydraulic transient processes are crucial for ensuring the safe, stable, and long-term operation of water transfer projects. This paper establishes a one-dimensional mathematical model based on sections of the Yinjiangjihuai long-distance water diversion project in China. The water supply requirements of the pipelines are categorized into two replenishment modes as follows: gravity supply and pump-pressurized water supply. The opening and closing strategies of the water pipelines under different flow conditions are simulated and analyzed to explore the hydraulic transient processes under various water supply modes. The transient variations of key hydraulic parameters during valve closure are clarified. Simulation results indicate that the water pipeline design is reasonable, meeting the water supply demands at relatively low Manning values and that it has the capability for long-term supply. Due to the excessive head provided by the pumps, pump-pressurized water supply and gravity supply modes cannot operate simultaneously. Under gravity supply mode, the minimum pressure in the downstream pipeline is relatively higher overall, while the maximum pressure in the upstream pipeline is relatively lower overall. In the pump-pressurized water supply mode, the safety and stability of the water supply can be ensured by adjusting the closing time of individual pumps and the interval time between adjacent pumps. The research findings provide technical guidance and scientific basis for the construction of national water networks and water transfer projects.

17 December 2024 in PLOS ONE
Verified
Journal Article
Open access
XZXiaolei Zhang
Xiaolei Zhang
XGXiaoyi GUO
Xiaoyi GUO
YCYading Chen
Yading Chen
CYChen Yang
Chen Yang
SLShuyu Liu
Shuyu Liu
LGLixia Guo
Lixia Guo
Hydraulic transients in long-distance pressurized water pipelines significantly impact their normal operation. This study develops a one-dimensional mathematical model for pressurized water pipelines using the method of characteristics and incorporates water hammer equations for dual-pipeline systems. The model is validated with experimental data, and simulations are conducted under real engineering conditions, focusing on valve closure operations. The analysis examines the transient responses for varying valve closure times (T) and the effect of installing surge tanks. Results show that increasing valve closure time and installing surge tanks both mitigate water hammer impacts. Specifically, when valve closure time exceeds 300 seconds, surge tanks reduce maximum pressure below the pipeline’s tolerance (Pmax) and decrease the number of nodes experiencing damaging negative pressures. This model effectively simulates hydraulic transients in dual-pipeline systems and provides a foundation for developing protective measures for pipeline operations.

3 March 2024 in Journal of Hydraulic Research
Verified
Journal Article
Closed access
SLShuyu Liu
Shuyu Liu
XZXiaolei Zhang
Xiaolei Zhang
XGXiaoyi GUO
Xiaoyi GUO
ZXZhiheng Xu
Zhiheng Xu
CYChen Yang
Chen Yang

1 January 2025 in Geofluids
Verified
Journal Article
Open access
HWHui Wang
Hui Wang
WDWeibing Du
Weibing Du
XLXin Li
Xin Li
XZXiaolei Zhang
Xiaolei Zhang
SLShuyu Liu
Shuyu Liu
XGXiaoyi GUO
Xiaoyi GUO
The study focuses on a key component of the Yangtze–Huaihe River Diversion Project—the Qiliqiao to Xincheng water supply pipeline section, which includes a megascale inverted siphon structure. A one‐dimensional mathematical model is developed to simulate water hammer phenomena in transmission pipelines containing the large siphon. A comparative analysis is conducted to evaluate the protective effects of linear and nonlinear valve closure strategies. The optimal valve closure scheme is explored by parameterizing the valve closing duration and buffering time. The impact of air valves installed near the inverted siphon during hydraulic transition processes is examined, and the transient variations of key hydraulic parameters during the entire valve closure operation are systematically characterized. Under long‐term operational conditions with Manning’s coefficient degradation, the designed pipeline maintains a hydraulic head surplus of 7.34 m, fully meeting long‐distance water supply requirements. Air valves effectively reduce the peak pressure magnitude by 80%. Under linear valve closure conditions, only the high‐elevation air valves exhibit significant exhaust behavior. In contrast, nonlinear closure strategies reduce the minimum internal pressure of the pipeline and suppress vaporization, thereby reducing the air valve discharge volume. Finally, the study identifies an optimal time coordination scheme by adjusting the closure timing of individual pumps and the interval between adjacent pump shutdowns.