Muhammad Saqib Mudabbar

Dr. Muhammad Saqib Mudabbar

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

22 December 2023 in Medicine
Verified
Journal Article
Open access
TYTing Yang
Ting Yang
MMMuhammad Saqib Mudabbar
Muhammad Saqib Mudabbar
MXMingxing Xu
Mingxing Xu
QXQingmei Xiang
Qingmei Xiang
BLBin Liu
Bin Liu
QFQiang Fu
Qiang Fu
Background: The prevalence of obesity is high. Bariatric surgery is an effective treatment for severe obesity; however, the induction phase of anesthesia in these patients poses a risk of hypotension. Esketamine, known for its sympathetic nervous system stimulation, may stabilize blood pressure during induction. This study aimed to investigate the effects of esketamine on blood pressure in bariatric surgery patients. Methods: This randomized controlled trial included 145 patients undergoing bariatric surgery. Patients were randomly assigned to receive esketamine or a control intervention during induction. Blood pressure and other vital signs were measured and compared between the 2 groups using statistical analyses. Results: Administration of esketamine increased blood pressure before intubation (T2). The incidence of hypotension was lower in the esketamine group at multiple time points during induction. Postoperatively, the esketamine group exhibited lower pain scores at 24 hours and a reduced need for rescue analgesics. Conclusion: A single dose of 0.2 mg/kg esketamine during the induction phase of bariatric surgery can improve blood pressure stability and decrease the incidence of hypotension. Furthermore, it is associated with reduced postoperative pain. Future studies could explore the effects of higher esketamine doses and validate these findings in a larger and more diverse patient population.

27 November 2024 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
TYTing Yang
Ting Yang
YLYong Liu
Yong Liu
FCFengHua Cai
FengHua Cai
YLYong Li
Yong Li
MMMuhammad Saqib Mudabbar
Muhammad Saqib Mudabbar
Background: Pulse oximeters are vital for assessing blood oxygen levels but can produce inaccurate readings during patient motion, leading to false alarms and alarm fatigue. Analog SpO2 Technology, which uses analog waveforms to filter motion artifacts, may improve accuracy compared to digital sensors. However, the effectiveness of this technology in reducing false alarms in clinical settings remains unclear. This study assesses and compares the motion resistance of Analog SpO2 Technology of two devices in the market. Methods: Thirty healthy adults underwent controlled experiments (Control, Linear Motion, Angular Motion) using two pulse oximeters. Linear Motion tested hand displacement impact, while Angular Motion involved rhythmic hand motions at 120 bpm and 160 bpm. Results: Both devices performed similarly in Control, with no disruptions. In Linear Motion, mild disruptions occurred, but no significant differences in SpO2 readings or alarms. Angular Motion at 120 bpm showed stability with no alarms. At 160 bpm, Device B (Biolight Analog SpO2) had fewer technical alarms but more SpO2 alarms than Device A (Masimo Analog SpO2). Conclusions: Analog SpO2 exhibited motion resistance under static, linear and continuous waving angular motion up to 120 bpm and 160 bpm, but alarms occurred at 160 bpm with continuous tapping angular motion. These findings signify non-inferiority of either device in clinical settings. Further studies should include patients with cardiovascular and/or respiratory diseases. Trial Registration: The study was submitted to and approved by the Biolight Ethics Committee (S0723), and written informed consent from all participants was obtained.