Initial perceptions of physicians can affect the level of comfort. Creating a strong rapport on the child's first visit helps to create a comfortable atmosphere. Child-friendly clothing of the dentists might possibly contribute to the dentist's empathy. Different attires may evoke different feelings. Hence, the purpose of the study was to assess the children's preferences for dentist's attire and its relation with anxiety. Eighty children aged 5-12 years were included in the study. Five photographs of dentists wearing different attires were placed in the same order for every child. The child was asked to look at the photographs and decide which dentist they would prefer to take care of them. A facial image scale was used to evaluate the child's anxiety level. The children were asked to point at which face they felt almost like at that moment. 42.7% of males and 38.5% of females chose child-friendly attire. The least preferred by males was a pink apron (7.5%) compared with females (28.1%). Whereas the blue apron was least preferred by females (5.1%) compared with males (20%). A Chi-square test was done to access the association between dental anxiety and the dental attire the children chose, where statistically significant (0.030) results were found. Anxious children were found to prefer child-friendly attire. Although the view that children are fearful of the white coat was not found, the concept of child-friendly attire might be more appropriate for anxious children and enhance an easy first communication with them. Sujatha P, Nara A, Avanti A, et al. Child Dental Patient's Anxiety and Preference for Dentist's Attire: A Cross-sectional Study. Int J Clin Pediatr Dent 2021;14(S-2):S107-S110.
1 January 2023 in Journal of Dental Anesthesia and Pain Medicine
The aim of this systematic review was to evaluate the effect of build orientation on the mechanical and physical properties of additively manufactured resin using digital light processing (DLP). The properties of 3D-printed materials are influenced by various factors, including the type of additive manufacturing (AM) system and build orientation. There is a scarcity of literature on the effect of build orientation on the mechanical and physical properties of additively manufactured resins using DLP technology in dentistry. This study followed the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines and was registered in PROSPERO. The formulated population, intervention, comparison, outcome (PICO) question was "What is the effect of build orientation on the mechanical and physical properties of additively manufactured resins produced using DLP in dentistry." The search strategy used three main electronic databases and an additional manual search was done until February 2024. All the studies that evaluated the correlation of build orientation and the properties of printed resin using DLP were included. Two different analysis was used for in vivo and in vitro studies to assess the risk of bias. On search 237 studies were yielded for systematic review, out of which 13 studies were included for the systematic review evaluation. On evaluation and reviewing the included studies, though the build orientation angle influenced the properties of printed resins the results obtained were varied as 90° angle had increased compressive strength, low surface roughness, and best accuracy. The 0° angle had better wear resistance, tensile strength, and high flexural strength. There was no influence of build orientation on microhardness, shear bond strength, gloss and color difference. The studies on denture base showed that 45° build angle showed the truest with best accuracy. The build orientation angle effects on both the mechanical and physical properties of the additively manufactured resin but varies with each property. The build orientation can be chosen based on the type of properties to be achieved based on the treatment modality. Based on the systematic review results the specific build orientation angle should be used during fabrication of any denture designs, crowns, and bridges as it is correlated with the properties to be achieved by particular designs. How to cite this article: Paranna S, Thosar N, Kanitkar A. Effect of Build Orientation on Mechanical and Physical Properties of Additively Manufactured Resins Using Digital Light Processing Technology in Dentistry: A Systematic Review. J Contemp Dent Pract 2024;25(9):891-903.
9 October 2020 in International Journal of Clinical Pediatric Dentistry
The aims and objectives of this study were to evaluate and compare the flexural strength and microhardness of zinc reinforced glass ionomer cement and glass ionomer type IX cement. The sample size of twenty each of group I (zinc-reinforced glass ionomer cement) and group II (glass ionomer type IX cement) were selected. The samples were prepared in the customized steel molds and subjected to test for flexural strength and microhardness. The flexural strength was determined by the three-point bending test. After determining the flexural strength, the fragments were used to determine Vickers Hardness by means of an automatic microhardness indenter. The flexural strength and microhardness was calculated for all samples and subjected to statistical analysis. Two sample t-test with unequal variances were used, as the data are found to be from the same material. The normality was checked by using the usual normal probability plot. For flexural strength, p value was found to be 0.007530. Hence, zinc-reinforced glass ionomer cement was superior to glass ionomer type IX cement. For microhardness the p value was found to be 0.0023. So, glass ionomer type IX cement was superior to zinc reinforced glass ionomer cement. The zinc-reinforced glass ionomer cement showed enhanced flexural strength when compared to glass ionomer type IX cement, thus increasing the longevity whereas glass ionomer type IX cement had a better microhardness than zinc-reinforced glass ionomer cement. Hence, the mechanical properties of various materials should be considered for the long-term clinical success by selecting the appropriate material based on the clinical condition. Patil K, Patel A, Kunte S, et al. Comparative Evaluation of the Mechanical Properties of Zinc-reinforced Glass Ionomer Cement and Glass Ionomer Type IX Cement: An In Vitro Study. Int J Clin Pediatr Dent 2020;13(4):381–389.
Background: Modern technologies have led to the development of new tools, practices, and digital techniques. However, their use in public health to provide adequate oral health facilities to the community is limited. One of the facilities that can help provide better oral health with minimal cost is teledentistry. The application of this approach will reduce inequalities in accessing oral healthcare. Knowledge of the use of teledentistry is of the utmost importance to its practice. Hence, the objective of this cross-sectional study is to assess the knowledge of and attitude regarding teledentistry among dental professionals in the Sangli district of Maharashtra. Materials and methods: A 24 -unit structured online validated questionnaire with six questions regarding participants' sociodemographic information and 18 questions related to their knowledge and attitude toward teledentistry and informed consent forms were circulated via email among 100 dentists, and the responses obtained were analyzed. Results: Out of 100 responses, 61 showed basic knowledge and a typical attitude toward teledentistry. Urban practitioners were more familiar with teledentistry than rural ones. Conclusion: This survey concludes that the branch of teledentistry still needs to be studied and publicized at a greater level to accelerate its widespread implementation in dentistry and especially to increase the outreach and time efficiency of dentistry.
5 December 2023 in Sri Lanka Journal of Child Health
Background: Dental biofilms are the primary aetiologic factors in the 2 most prevalent oral diseases, dental caries and periodontal disease. Among all oral hygiene methods available, mechanical plaque removal with a toothbrush is the primary mode of maintaining good oral hygiene.Objectives: Comparative evaluation of plaque removal efficacy and quantitative analysis of Streptococcus mutans in saliva after using nylon and charcoal bristles toothbrushes in children.Method: Forty healthy children aged 8-10 years having decayed-missing-filled-tooth (DMFT) score less than 5 were randomly allocated into two groups, one using charcoal bristles and the other using nylon bristles toothbrush. Loe & Silness Plaque Index was recorded along with saliva sample collection for Streptococcus mutans count before and after using the respective toothbrushes for 1 week.Results: A significant reduction in plaque index was observed in each group with a non-significant reduction in Streptococcus mutans CFU. However, the comparison between the two groups was not statistically significant.Conclusions: This randomised, parallel, singleblinded clinical study demonstrated that both nylon and charcoal bristles toothbrushes significantly enhanced plaque control but there was no significant difference in the two methods. There was no significant reduction in Streptococcus mutans CFU.