Magdy Eteiba

Dr. Magdy Eteiba


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
MHMirna Fouad Ali Abu Haggar
Mirna Fouad Ali Abu Haggar
EBEman Beshr
Eman Beshr
MEMagdy Eteiba
Magdy Eteiba
Transformations are taking place within the distribution systems to cope with the congestions and reliability concerns. This paper presents a new technique to efficiently minimize power losses within the distribution system by optimally sizing and placing distributed generators (DGs) while considering network reconfiguration. The proposed technique is a hybridization of two metaheuristic-based algorithms: Grey Wolf Optimizer (GWO) and Particle Swarm Optimizer (PSO), which solve the network reconfiguration problem by optimally installing different DG types (conventional and renewable-based). Case studies carried out showed the proposed hybrid technique outperformed each algorithm operating individually regarding both voltage profile and reduction in system losses. Case studies are carried to measure and compare the performance of the proposed technique on three different works: IEEE 33-bus, IEEE 69-bus radial distribution system, and an actual 78-bus distribution system located at Cairo, Egypt. The integration of renewable energy with the distribution network, such as photovoltaic (PV) arrays, is recommended since Cairo enjoys an excellent actual record of irradiance according to the PV map of Egypt.

16 September 2019 in Energies
Verified
Journal Article
Open access
PDF file
DYDalia Yousri
Dalia Yousri
THANIKANTI SUDHAKAR BABUTHANIKANTI SUDHAKAR BABU
THANIKANTI SUDHAKAR BABU
DADalia Allam
Dalia Allam
VRVigna Kumaran Ramachandaramurthy
Vigna Kumaran Ramachandaramurthy
EBEman Beshr
Eman Beshr
MEMagdy Eteiba
Magdy Eteiba
Solar Photovoltaic (PV) systems have become prominent and have attained the attention of energy engineers, governments and researchers. To achieve the maximum benefit from the PV system in spite of its nonlinear characteristic and environmental conditions, finding a robust maximum power point tracking method is essential. Over two decades, various researchers proposed numerous MPPT methods, but they failed to evaluate their methods on consistency, reliability, and robustness over several numbers of runs. Most of the researchers examined one configuration and they did not to consider the dynamic change in the irradiation conditions. Therefore, in this manuscript, the authors introduced a novel optimization technique Fractional chaotic Flower Pollination Algorithm (FC-FPA), by merging fractional chaos maps with flower pollination algorithm (FPA). The proposed technique, help FPA in extracting the Global Maximum Power Point (GMPP) under different partial shading patterns including with different PV array configurations. The proposed FC-FPA technique is tested and evaluated over 5 different patterns of partial shading conditions. The first three patterns are tested over 4S configuration made with Shell S36 PV module. The other two patterns are applied to the 4S2P configuration of Shell SM55 PV panels. The performance of the proposed variant is investigated by tracking the GMPP for abruptly changing shade pattern. Exclusive statistical analysis is performed over several numbers of runs. Comparison with perturb and observe MPPT technique is established. These results confirm that, the proposed method shows fast convergence, zero oscillation and rapid response for the dynamic change in irradiation with consistent behavior.

28 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
MSMohamed Sayed Seddik
Mohamed Sayed Seddik
MEMagdy Eteiba
Magdy Eteiba
JSJehan Shazly
Jehan Shazly
Harmonics in the power grid contribute to increased power losses in both the core and windings of power transformers. These losses lead to abnormal rises in temperature causing overheating and reduce the efficiency of the transformer. If the losses and temperature exceed the values set during the design stage for linear load conditions, it can damage the transformer’s insulating materials and shorten its lifespan. To assess the thermal impact of power system harmonics on transformers under steady-state and transient conditions, the rated losses and harmonic losses of the transformer are calculated. These losses are then inputted into a developed thermal 3D finite element method (FEM) performance model to determine the temperature distribution of transformer components. The numerical results from the thermal model will be compared with data from a Hyundai test report and real measurements from Egypt’s Kureimat power plant, specifically a 750 MW combined cycle power plant. The thermal modeling is focused on a step-up (16.5/240 kV), 240 ± 4 × 2.5%, 180/240/300 MVA power transformer operating in ONAN, ONAF1, and ONAF2 modes. This paper shows that the developed model aligns closely with actual measurements and the HYUNDAI test report. The loss calculations reveal that the discrepancy in total losses, with and without accounting for harmonics, becomes more pronounced as the load increases. Using this model, the presence of grid harmonics results in a higher temperature distribution across transformer components, leading to an increase in the hot spot temperature.

6 December 2019 in Iranian Journal of Science and Technology, Transactions of Electrical Engineering
Verified
Journal Article
Closed access
PDF file
DYDalia Yousri
Dalia Yousri
DADalia Allam
Dalia Allam
MEMagdy Eteiba
Magdy Eteiba
PSPonnuthurai Nagaratnam Suganthan
Ponnuthurai Nagaratnam Suganthan

29 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
MSMohamed Sayed Seddik
Mohamed Sayed Seddik
JSJehan Shazly
Jehan Shazly
MEMagdy Eteiba
Magdy Eteiba
An accurate simulation and computational analysis of temperature distribution in large power transformers used in power plants is crucial during both the design and operational phases. This study introduces a thermal modeling analysis encompassing two- and three-dimensional (2D and 3D) approaches for power transformers. The mathematical model for heat diffusion follows the Finite Element Method (FEM) approach. Validation of the computed results involves comparing them against measurements from Hyundai’s test report for both 2D and 3D models, aiming to identify the most effective solution. Additionally, the thermal dynamics of power transformers under diverse operational conditions, specifically oil-immersed ones, are examined. The efficacy of this model is confirmed through testing on a step-up transformer at Kureimat station in Egypt, with specifications including three-phase, 50 Hz, 16.5/240 KV, nine taps, and cooling type (ONAN/ONAF1/ONAF2).

7 May 2020 in Neural Computing and Applications
Verified
Journal Article
Closed access
PDF file
DYDalia Yousri
Dalia Yousri
DADalia Allam
Dalia Allam
THANIKANTI SUDHAKAR BABUTHANIKANTI SUDHAKAR BABU
THANIKANTI SUDHAKAR BABU
AAAmr AbdelAty
Amr AbdelAty
Ahmed G. RadwanAhmed G. Radwan
Ahmed G. Radwan
MEMagdy Eteiba
Magdy Eteiba