Damian Cebulski

Mr. Damian Cebulski

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
DCDamian Cebulski
Damian Cebulski
PCPiotr Jerzy Cyklis
Piotr Jerzy Cyklis
Drying and sanitising equipment has been very common in industrial plants since the pandemic. These are devices that consume significant amounts of energy. The best solution is to use a drying chamber equipped with a heat pump, which allows partial recovery of the energy. In the design of the drying chamber, the drying time is important, which depends both on the parameters of the heat pump itself, and the geometry and airflow of the drying chamber. The geometry and airflow supply should be arranged to ensure a uniform distribution of velocity throughout the drying area. For this purpose, the use of CFD simulations has been proposed. A model was developed in ANSYS/FLUENT where all model parameters, including the optimal mesh density, turbulence models, etc., were determined. The model was verified on the experimental results of the basic design of the chamber. Then an innovative design was proposed that was modelled and optimised in terms of the distribution of the inlet’s perforation. The final design was made, and, at the same time, the simulation’s results were verified by measuring the velocity of airflow in the new design. Together with the optimisation of the heat pump, this made it possible to reduce the drying time by 50%, with a simultaneous reduction in the energy consumed.

20 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
DCDamian Cebulski
Damian Cebulski
PCPiotr Jerzy Cyklis
Piotr Jerzy Cyklis
Common designs of workwear drying units require not only energy efficiency but also effective disinfection. One possibility of sanitising clothes during drying is to use the ozone generated inside the drying chamber. This process requires precise management of airflow and a uniform distribution of ozone in the chamber. Therefore, optimising the shape of the drying chamber must include not only the correct flow of drying air but also the correct distribution of ozone. This paper addresses the difficult problem of modelling the flow of sanitising ozone in an innovative drying chamber. The innovative shape of the chamber is shown in this article. Due to the low percentage of ozone in the air (up to 10 ppm), CFD simulation models of the usual mixture type are too inaccurate; therefore, special models have to be used. Therefore, this paper presents an experimentally verified methodology to simulate ozone flow in an innovative drying and sanitising cabinet using two methods: Discrete Phase Model (DPM) and Species Transport (ST). The DPM method uses a Euler–Lagrange approach to qualitatively assess the spread of ozone particles, treated with a description of the movement of the particles and not as a continuous gaseous substance. On the other hand, this already allows the verification of ozone concentrations, with an appropriate conversion of the measured quantities. The ANSYS/FLUENT 2023R1 program was used for the simulations after careful selection of the mesh, closing models, boundary conditions, etc. Simulations made it possible to analyse the distribution of ozone in the workspace and assess the effectiveness of the sanitisation process. The results of the simulations were verified on the basis of empirical tests, which showed the correctness of the model and the correct distribution of the sanitising ozone in the entire volume of the drying chamber in the innovative drying–sanitising chamber. The complete simulation of the air and ozone distribution using the presented models allowed for the optimisation of the opening and shapes, which contributed to improving the energy efficiency of the unit and increasing the efficiency of the sanitisation processes, making the described methodology very effective for optimising the chambers of various types of dryers.

1 January 2022 in Technical Transactions
Verified
Journal Article
Open access
PDF file
TMTomasz Mołczan
Tomasz Mołczan
DCDamian Cebulski
Damian Cebulski
MPMarcin Piasecki
Marcin Piasecki
PCPiotr Jerzy Cyklis
Piotr Jerzy Cyklis
This article describes how an energy audit of equipment and the resulting design changes can have a major impact on reducing the electricity consumption of refrigeration equipment. The legal basis introduced by legislation forcing work on the improvement of refrigeration unit is provided. Eight points detail and describe the changes applied to the construction of cooling units. Additionally, a list of the refrigerants which are used is presented, along with the essential parameters of their work. The following analysis includes a description of the research performed along with the measured and calculated results for individual optimisations. The basic parameters that were used for comparison are: daily electricity consumption [kWh/24 h] and the temperature of the packages placed in the device [°C]. Finally, the percentage differences in energy consumption for each modernisation are summarised in a tabular form. The device used for the tests was the VARNA refrigerated rack, model 900, manufactured by P.P.H.U. JUKA Sp. z o.o. sp. k.