Christian Seiler

Dr. Christian Seiler


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2017 in Materials
Verified
Journal Article
Open access
PDF file
MGMichael Grau
Michael Grau
CSChristian Seiler
Christian Seiler
LRLaura Roland
Laura Roland
JMJulia Matena
Julia Matena
CWClaudia Windhövel
Claudia Windhövel
INIngo Nolte
Ingo Nolte
Metallic biomaterials are widely used in maxillofacial surgery. While titanium is presumed to be the gold standard, magnesium-based implants are a current topic of interest and investigation due to their biocompatible, osteoconductive and degradable properties. This study investigates the effects of poly-ε-caprolactone-coated and previtalised magnesium implants on osteointegration within murine calvarial bone defects: After setting a 3 mm × 3 mm defect into the calvaria of 40 BALB/c mice the animals were treated with poly-ε-caprolactone-coated porous magnesium implants (without previtalisation or previtalised with either osteoblasts or adipose derived mesenchymal stem cells), porous Ti6Al4V implants or without any implant. To evaluate bone formation and implant degradation, micro-computertomographic scans were performed at day 0, 28, 56 and 84 after surgery. Additionally, histological thin sections were prepared and evaluated histomorphometrically. The outcomes revealed no significant differences within the differently treated groups regarding bone formation and the amount of osteoid. While the implant degradation resulted in implant shifting, both implant geometry and previtalisation appeared to have positive effects on vascularisation. Although adjustments in degradation behaviour and implant fixation are indicated, this study still considers magnesium as a promising alternative to titanium-based implants in maxillofacial surgery in future.

4 September 2024 in Atmosphere-Ocean
Verified
Journal Article
Open access
RNRaj Deepak S. N.
Raj Deepak S. N.
CSChristian Seiler
Christian Seiler
AMAdam H. Monahan
Adam H. Monahan

20 August 2019 in Acta Veterinaria Scandinavica
Verified
Journal Article
Open access
PDF file
GPGerrit Pöhlmann
Gerrit Pöhlmann
MLMatthias Lüpke
Matthias Lüpke
CSChristian Seiler
Christian Seiler
PWPatrick Wefstaedt
Patrick Wefstaedt
JBJan-Peter Bach
Jan-Peter Bach
HSHermann Seifert
Hermann Seifert
Technical failures and incorrect usage of digital X-ray systems may lead to a decreasing image quality, artefacts and a higher dose exposure of staff and patients. Although there are no regulations regarding constancy testing in veterinary radiology all operators are required to avoid unnecessary exposure. The aim of this study was to develop a reasonably inexpensive zoomorphic 3D-printed test specimen for constancy testing that allows the detection of changing image quality by visual analysis. Primarily, a calibration curve of the attenuation factor of the 3D-printing material (ZP150) was determined. MATLAB converted every pixel value of a thorax X-ray image of a Beagle dog into an equivalent thickness of printing material. The thickness distribution was printed using a 3D-printer. This printed test specimen was additionally provided with five thin aluminium discs to simulate lung nodules. To evaluate the usability for constancy testing 12 X-ray images of the test specimen were made. Two images (reference and control) were taken with the minimum dose in order to obtain images suitable for diagnosis purposes. Eight images were taken with a dose differing 30–140% from the reference dose by varying current–time product (mAs) or tube voltage (kVp). Two images were taken with the same parameters as the reference image but edited with different image processing. Six veterinarians (general practitioners) evaluated ten chosen structures in the X-ray images in a Visual Grading Analysis and scored the image quality of these structures for every image in comparison to the reference image. A Visual Grading Analysis Score was calculated and statistically analysed. A higher current–time product led to a negligibly better evaluation of the X-ray image. The lower the current–time product the worse the X-ray images were scored. Likewise, both increasing and decreasing of the tube voltage led to lower scores. A zoomorphic test specimen can be used for constancy testing of digital X-ray systems in veterinary medicine. Especially a lower dose can be recognised due to deviation in the image quality when compared to the reference image. The 3D-printed test specimen is less expensive than test equipment used in human medicine.

16 June 2021 in Irish Veterinary Journal
Verified
Journal Article
Open access
PDF file
IPIoannis Proios
Ioannis Proios
MKMarian Kusenda
Marian Kusenda
CSChristian Seiler
Christian Seiler
CSCarsten Siewert
Carsten Siewert
HSHermann Seifert
Hermann Seifert
MKMartin Kaske
Martin Kaske
Background: As part of clinical wound assessment in bovine surgery, discrepancies in skin temperature are evaluated by placing the back of the hand on the area to be examined. Generally, an increased skin temperature at the wound site for a prolonged period is considered as an indicator of impaired wound healing.The aim of this study was to verify the reliability of palpation under bovine practice conditions using laparotomy as an example. Fourteen cows (German Holstein) with a left displacement of the abomasum (LDA) without other severe concurrent diseases were examined preoperatively and once daily for ten days after surgery. The skin temperature of the wound site in the right flank was assessed by palpation, followed by thermographic evaluation using an infrared camera after a 45-min acclimatisation period, under standardised conditions in a closed examination room daily for 10 days.Results: All the incisions healed without clinical detectable perturbances. The ambient temperature range during the study period was 7.8 − 24.1 °C. Two groups were retrospectively defined according to the ambient temperature: high ambient temperature (HT group; median: 20.2 °C 25/75 quartile: 18.5 °C / 21.7 °C;n = 6) and low ambient temperature (LT group; 10.8 °C; 9.4 °C / 12.8 °C;n = 8). The temperature differences (Δϑ) between the mean skin temperature of the wound site and a defined reference area cranial to the wound were assessed. A significant negative correlation was found between the ambient temperature (ϑAmb) and Δϑ (r=-0.51;P < 0.001). The Δϑ was postoperatively higher in the cows in the LT group (median of the individual animals 0.8–2.5 °C) than in the HT group (0.1–0.5 °C;P < 0.05). In contrast to the thermographic findings, manual palpation rarely detected local hyperthermia (> 1 °C) at the wound site (sensitivity 0.20; specificity 0.96).Conclusions: The infrared thermography provides a more reliable assessment of temperature changes at the wound site in comparison to manual palpation. The ambient temperature markedly affects the extent of local hyperthermia at the wound site.

15 July 2022 in Veterinarni Medicina
Verified
Journal Article
Open access
PDF file
CSChristian Seiler
Christian Seiler
MLM Luepke
M Luepke
JBJp Bach
Jp Bach
HSH Seifert
H Seifert
Preparation of artificial vascularised tissue and the indirect determination of its void volume using µCT | C Seiler, M Luepke, JP Bach, H Seifert | Agricultural Journals