Francisco J. Castro

Dr. Francisco J. Castro

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2003 in Journal of Diabetes and its Complications
Verified
Journal Article
Closed access
JGJosé A Gimeno-Orna
José A Gimeno-Orna
Francisco J. CastroFrancisco J. Castro
Francisco J. Castro
BBBeatriz Boned-Juliani
Beatriz Boned-Juliani
LLLuis M Lou-Arnal
Luis M Lou-Arnal

18 December 2020 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
Carlos Rocha-de-LossadaCarlos Rocha-de-Lossada
Carlos Rocha-de-Lossada
ECElvira Colmenero-Reina
Elvira Colmenero-Reina
DFDavid Flikier
David Flikier
Francisco J. CastroFrancisco J. Castro
Francisco J. Castro
ARAlvaro Rodriguez-Raton
Alvaro Rodriguez-Raton
José-María Sánchez-GonzálezJosé-María Sánchez-González
José-María Sánchez-González
Purpose: To evaluate the accuracy of 12 intraocular lens (IOL) power formulas; Barrett Universal II, Emmetropia Verifying Optical (EVO), Haigis, Hill-Radial Basis Function (RBF), Hoffer Q, Holladay I, Kane, Ladas Super Formula, Olsen Lenstar, Panacea, Pearl-DGS, Sanders-Retzlaff-Kraff/theoretical (SRK/T). In addition, an analysis of the efficacy as a function of the axial length was performed. Methods: About 171 from 93 patients: 68 male eyes and 103 female eyes. Twelve IOL power formula calculations were studied with one IOL platform (trifocal hydrophilic IOL, FineVision Micro F), one biometer (Lenstar LS 900), one topographer (CSO Sirius Topographer), one surgeon, and one optometrist. Optimization were determined to be zeroed mean refractive prediction error. Mean error (ME), mean absolute error (MAE), median absolute error (MedAE) and refractive accuracy within ±1.00 D was calculated. Axial length was split in short and medium eyes. Results: One hundred and seventy eyes were included. Formulas were ranked by percentage within ±0.50 diopters and MAE (D). Among all eyes, Olsen 86.55% (0.273 D) and Barrett Universal II 86.55% (0.285D). For short eyes (<22.5 mm), Olsen 90.70% (0.273 D) and Kane 90.70% (0.225 D). For medium eyes, Barrett 89.34% (0.237 D) and Pearl 86.89% (0.263 D). Conclusion: Olsen and Barrett formula obtained excellent accuracy for overall eyes. Kane and Olsen formula obtained the best results in short eyes. For medium axial length Barrett formula achieved the best accuracy results.

15 May 2009 in The American Journal of Cardiology
Verified
Journal Article
Closed access
JGJosé Antonio Gimeno-Orna
José Antonio Gimeno-Orna
EFEduardo Faure-Nogueras
Eduardo Faure-Nogueras
Francisco J. CastroFrancisco J. Castro
Francisco J. Castro
BBBeatriz Boned-Juliani
Beatriz Boned-Juliani

1 July 2024 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
MGMarta Jiménez García
Marta Jiménez García
FSFrancisco J. Segura-Calvo
Francisco J. Segura-Calvo
MPMartín Puzo
Martín Puzo
Francisco J. CastroFrancisco J. Castro
Francisco J. Castro
OZon behalf of the UFR-ARCCA Group Zaragoza
on behalf of the UFR-ARCCA Group Zaragoza
Purpose: To describe gender differences in the biometric parameters of a large sample of patients with cataract. Cataract surgery has evolved from a vision restoration to a refractive procedure, and population-based studies are vital to optimize normative databases and postsurgical outcomes. Setting: Miguel Servet University Hospital, Zaragoza, Spain. Design: Retrospective single-center observational study. Methods: The study included 34 589 eyes (20 004 patients with cataract). Biometric data were obtained from IOL Master 700 and Pentacam HR. Linear mixed models were used to account for intereye correlation. HofferQST formula was used to calculate the hypothetical distribution of intraocular lens (IOL) power (arbitrary lens; A = 119.2). Results: Most biometric variables showed significant differences between sexes (P < .0001), such as 0.53 mm shorter eyes found in females, of which 0.16 mm are explained by shorter aqueous depth. Steeper anterior keratometries (∼0.75 diopter [D]) were found in women, to end up in no difference on anterior astigmatism magnitude, but different orientation (P < .0001). The distribution of IOL power differed between sexes (P < .001), with the interquartile range shifting 1 D toward more powerful lenses in women and odds ratio (power >26 D) = 2.26, P < .0001 (Fisher). Conclusions: Large sample size studies provide smaller margin of error, higher power, and controlled risk of reporting false (negative or positive) findings. Highly significant differences between sexes in ocular biometry were found; this supports the idea that including sex as a parameter in IOL calculation should be explored and may improve results. In addition, the distribution of IOL powers was provided, which may be useful for manufacturers and hospital stock planning.

1 September 2019 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
Francisco J. CastroFrancisco J. Castro
Francisco J. Castro
DBDaniel Bordonaba-Bosque
Daniel Bordonaba-Bosque
David P PiñeroDavid P Piñero
David P Piñero
BLBeatriz Latre-Rebled
Beatriz Latre-Rebled
Purpose: To investigate the predictive value of the intracrystalline interphase point (ICIP) measured with optical low-coherence reflectometry (OCLR) to estimate the final lens position (FLP) of an intraocular lens (IOL) after cataract surgery. Setting: Alcaniz Hospital, Teruel, Spain. Design: Single-center retrospective descriptive study. Methods: Patients undergoing cataract surgery were enrolled. They were grouped according to the IOL implanted as follows: Group 1, Acrysof IC) aspheric SN60WF IOL (77 eyes); Group 2, enVista MX60 IOL (71 eyes); Group 3, CT Asphina 409 IOL (44 eyes). An OCLR-based biometer (Lenstar LS 900 system) was used for biometric measurements preoperatively and at 4 to 5 weeks postoperatively. Results: The study comprised 192 eyes of 174 patients (mean age: 76.4 years). One hundred seventy eyes (88.5%) eyes showed an absolute refractive prediction error (ARPE) less than 0.50 diopters (D). The mean ARPE was 0.25 D +/- 0.21 (SD). Significantly higher FLP values were found in Group 2 compared with the other two groups (P < .001). Significantly lower ICIP values were found in the eyes with an ARPE of 0.50 D or more compared with eyes that had an ARPE less than 0.50 D in Group 1 (P = .042) and Group 2 (P = .023). The correlation of the FLP with the ICIP was good in all three groups (r >= 0.74, P <.001). Three linear expressions were obtained to predict the FLP from the ICIP and other preoperative data (R-2 : 0.85, 0.69, and 0.49 in Groups 1, 2, and 3, respectively). Conclusions: The position of the ICIP measured with OCLR correlated with the FLP after cataract surgery, and it can be used to optimize IOL power calculations. (C) 2019 ASCRS and ESCRS

31 October 2006 in Diabetes Research and Clinical Practice
Verified
Journal Article
Closed access
JGJosé Antonio Gimeno-Orna
José Antonio Gimeno-Orna
EMEdmundo Molinero-Herguedas
Edmundo Molinero-Herguedas
RSRaquel Sánchez-Vaño
Raquel Sánchez-Vaño
LLLuis M. Lou-Arnal
Luis M. Lou-Arnal
BBBeatriz Boned-Juliani
Beatriz Boned-Juliani
Francisco J. CastroFrancisco J. Castro
Francisco J. Castro