Halil Sezen

Prof. Halil Sezen


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2009 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
ADAdem Dogangun
Adem Dogangun
ZKZeki Karaca
Zeki Karaca
ADAhmet Durmus
Ahmet Durmus
Halil SezenHalil Sezen
Halil Sezen
Silos are special structures subjected to many different unconventional loading conditions, which result in unusual failure modes. Failure of a silo can be devastating as it can result in loss of the container, contamination of the material it contains, loss of material, cleanup, replacement costs, environmental damage, and possible injury or loss of life. Silo damage and failures that occurred in different regions of the world are presented in the paper using illustrative photos. Also provided are a review and discussion of the common or spectacular silo failures due to explosion and bursting, asymmetrical loads created during filling or discharging, large and nonuniform soil pressure, corrosion of metal silos, deterioration of concrete silos due to silage acids, internal structural collapse, and thermal ratcheting. Silo damage and failures from several earthquakes are also presented.

1 February 2009 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
KYKyong Y. Yeau
Kyong Y. Yeau
Halil SezenHalil Sezen
Halil Sezen
PFPatrick J. Fox
Patrick J. Fox
This paper presents the results of field performance tests of 39 in-service corrugated steel highway culverts in Ohio. The culverts had span lengths varying from 3.23 m (10.6 ft) to 7.04 m (23.1 ft) and backfill soil heights over the crown varying from 0.27 m (0.9 ft) to 7.47 m (24.5 ft) . Static and dynamic load tests were conducted by driving heavy trucks across the culverts. Static loads were applied at ten different locations above each culvert. Dynamic load tests were conducted at six truck speeds varying from 8 km∕h (5 mi∕h) to 64 km∕h (40 mi∕h) . A portable instrumentation frame was installed inside each test culvert to monitor deflections. Strains on the culvert walls were also measured at 14 locations using strain gauges. Effects of backfill height and loading conditions are investigated. According to the experimental results, a plot of maximum culvert deflection versus backfill height shows a nonlinear relationship. Maximum static load deflections were found to be consistently larger than the ma...

1 March 2011 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
Halil SezenHalil Sezen
Halil Sezen
EMEric A. Miller
Eric A. Miller
Insufficient or deteriorating reinforced-concrete piers in many existing bridges are required to be strengthened using economical, fast, and efficient methods. Currently, only a few methods can be used to strengthen circular columns. Steel jackets and fiber-reinforced polymer (FRP) composites are the two commonly used methods. In this study, along with these two strengthening methods, concrete jackets reinforced with spiral rebar, welded wire fabric (WWF), and a new steel reinforcement called PCS are investigated under different axial-load applications. Fifteen identical specimens were constructed, strengthened, and tested: one column with no strengthening; three columns strengthened with FRP; two with steel jacketing; and nine with concrete jacketing (two with WWF, three with spiral rebar, and four with the new reinforcement). The bare or unretrofitted specimens had a 152 mm (6 in.) diameter, while the outside diameter of concrete-jacketed specimens was 254 mm (10 in.). Effectiveness of each strengthenin...

1 October 2012 in Journal of Composites for Construction
Verified
Journal Article
Closed access
Halil SezenHalil Sezen
Halil Sezen
Three exterior reinforced concrete beam-column joint specimens were tested under reverse cyclic loading. The joint region of these specimens suffered significant damage, whereas limited damage was observed in the beams. The damaged specimens were repaired and strengthened to prevent shear damage and strength deterioration inside the joint region and to achieve more ductile response. First, the damaged loose concrete was removed and replaced by high-strength nonshrink mortar. Then, fiber-reinforced polymer (FRP) strips were diagonally wrapped over the joint region, and longitudinal FRP strips were applied and anchored on the beams. The original strength was restored in all strengthened specimens under the application of the same loading history. Deformation capacities of the strengthened specimens were much larger than those of the original specimens.

1 August 2008 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
Halil SezenHalil Sezen
Halil Sezen
KYKyong Y. Yeau
Kyong Y. Yeau
PFPatrick J. Fox
Patrick J. Fox
A large number of corrugated metal pipe-arch culverts are located under highways. This study investigates the field performance of four existing pipe-arch culverts under static and dynamic loads. Effects of various parameters were considered in selection of the culverts, including backfill height, loading conditions, age of placement, and culvert geometry. Static loads were applied at ten different locations above each culvert using heavily loaded test trucks. Six dynamic tests were conducted at speeds varying from 8 to 64 km∕h . A portable instrumentation frame was installed inside each test culvert to monitor the deflections at five critical locations. During each test, strains were also measured using 14 strain gauges. Test results indicated that culvert response was influenced significantly by the backfill height. Nearly symmetrical deflection patterns were recorded for symmetrical loading about the longitudinal vertical plane through the crown. The maximum static deflections were larger than the maxi...

1 November 2011 in Practice Periodical on Structural Design and Construction
Verified
Journal Article
Closed access
JDJoseph M. Danatzko
Joseph M. Danatzko
Halil SezenHalil Sezen
Halil Sezen
Modern society is demanding that the use of energy associated with construction and operation of structures be investigated during the planning and design phases. The engineering community has been striving to design more sustainable buildings in an attempt to reduce both raw material requirements and energy use during all phases of design. Structural engineers currently have very limited guidance on how to incorporate sustainability concepts in their designs. Innovative methods are needed to address the environmental impact, energy use, and other sustainability issues faced during planning and design of buildings. This paper investigates and discusses five sustainable structural design methodologies: Minimizing Material Use, Minimizing Material Production Energy, Minimizing Embodied Energy, Life-Cycle Analysis/Inventory/Assessment, and Maximizing Structural System Reuse. The goal of this paper is to describe and address issues associated with the proposed design methodologies to determine which, if any, ...