Carolin Erbel

Ms. Carolin Erbel


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
KSKirsten Sekura
Kirsten Sekura
CECarolin Erbel
Carolin Erbel
Matthias KarlMatthias Karl
Matthias Karl
TGTanja Grobecker-Karl
Tanja Grobecker-Karl
Mechanical and thermal trauma during implant surgery may be reasons for initial peri-implant bone loss. Temperature development during drilling and implant insertion were quantified in this series of in vitro and animal experiments. Polyurethane foam material mimicking different classes of alveolar bone was used as a model material for simulating implant surgery. Using thermocouples, temperature development was determined in the model material at depths of 3 mm and 10 mm during site preparation and implant insertion. Additionally, an infrared camera allowed for measuring drill temperatures both in vitro and as part of an animal trial using an intraoral minipig model. Drill diameter and repeated usage of drills did not have a major effect on temperature generation. The addition of a diamond-like carbon coating, bone density, predrilling, and irrigation heavily affected intraosseous temperatures. In vivo, applying regular drill protocols, an intraosseous temperature rise of approximately 3 °K was determined. Implant geometry as well as the amount of undersizing of an osteotomy governed heat generation during implant insertion. Drill protocols and the amount of undersizing of an implant osteotomy constitute parameters by which clinicians can limit trauma during implant surgery.

Verified
Journal Article
Open access
PDF file
CECarolin Erbel
Carolin Erbel
MLMatthias W. Laschke
Matthias W. Laschke
TGTanja Grobecker-Karl
Tanja Grobecker-Karl
Matthias KarlMatthias Karl
Matthias Karl
This animal study compared the healing performance of a novel implant design characterized by a shift in thread geometry and core diameter with two different surfaces with that of an apically tapered implant. Test Bioactive (n = 9), Test Porous (n = 7) and Control (n = 8) implants were placed in the mandibles of minipigs. Following healing, bone samples were harvested for determining bone-to-implant contact (BIC) and marginal bone loss (MBL). Comparative statistics were based on Levene’s test, Shapiro–Wilk tests, the Kruskal–Wallis test and Wilcoxon tests with Holm correction (α = 0.05). The mean undersizing of the osteotomy was 0.15 mm for Control, while in the test groups 0.33 mm and 0.34 mm were calculated. Insertion torques ranged from 61.5 Ncm (Control) to 76.1 Ncm (Test Bioactive). Maximum BIC was seen in Test Porous with 55.83%, while Test Bioactive showed only 48.11%. MBL was 4.1 mm in Test Bioactive, while Test Porous and Control exhibited 2.8 mm. No significant differences between the implant groups were observed (p > 0.05). Despite greater undersizing, the novel implant type performed comparably to the established Control implants. The rougher surface of the bioactive implants increased the insertion torque and led to more MBL.