Purpose: To describe features of uveitis-glaucoma-hyphema (UGH) syndrome, using Anterior Segment-Optical Coherence Tomography (AS-OCT) and Ultrasound Biomicroscopy (UBM) and to evaluate the diagnostic role of AS-OCT as an imaging technique alternative to UBM. Design: Retrospective case series. Methods: Four eyes of 4 patients with UGH syndrome were analyzed. All patients reported previous uncomplicated cataract surgery with in-the-bag implantation of single-piece-intraocular lens (IOL). They underwent at presentation complete ophthalmological examination and imaging with slit-lamp anterior segment photographs, UBM and AS-OCT. Results: Although AS-OCT did not allow to visualize the structures behind the iris, it displayed a contact between IOL (plate and/or haptics) and iris and IOL tilting in 3 out of 4 eyes. AS-OCT directly detected the cause of UGH syndrome in one eye, 2 eyes required some expedients to display the iris chafing, like scans in mydriasis and/or patient's gaze direction change. AS-OCT did not allow to appreciate the IOL-iris contact (showed by UBM technique) only in one eye, probably due to the change of patient position from supine to sitting, and consequent anteriorization of iris diaphragm. Furthermore AS-OCT showed fine details, as capsular bag collapse and indirect signs of haptic malposition in 3 out of 4 eyes. Conclusion: AS-OCT is a non-invasive technique that allows to determine IOL position and IOL-uveal contact in selected cases of UGH syndrome. Considering AS-OCT and UBM advantages and limitations, AS-OCT should be used as first imaging modality when clinical diagnosis is uncertain. When UGH diagnosis cannot be verified using AS-OCT, UBM should be performed.
Aim: To evaluate the effectiveness of pars plana vitrectomy (PPV) without macular intervention on uveitis eyes with persistent vitreous inflammation/opacities in terms of visual acuity (VA), intraocular inflammation and macular profile. Methods: We carried out a single-center retrospective study of patients with uveitic eyes that underwent PPV without intervention on the macula due to persistent vitreous inflammation/opacities. The primary outcome measures were best-corrected visual acuity (BCVA), intraocular inflammation and macular profile at 3, 12 and 24 months after surgery. Results: Twenty-seven eyes of twenty-six patients were analyzed. Overall, 77.8% had an improvement of VA (55% by 0.3 LogMAR or more); 62.5% of patients had no intraocular inflammation, and the number of patients on systemic steroids and second-line immunosuppressives was reduced by 26% at 12 months; 87.5% of patients had resolution of macular oedema at 12 months. Conclusion: PPV for persistent vitreous inflammation/opacities is safe and effective, showing beneficial outcomes in terms of improvement of BCVA and the reduction in inflammation.
28 January 2021 in European Journal of Ophthalmology
Purpose: To evaluate the correlation between Best Corrected Visual Acuity (BCVA) and the following parameters in Stargardt Disease (STGD): Central Retinal Thickness (CR-T), Central Outer Nuclear Layer Thickness (C-ONL-T), Areas of macular Photoreceptor loss (PHRa), and Retinal Pigment Epithelium (RPE) loss (RPEa). Methods: A total of 64 eyes of 32 STGD patients were included in the study. All patients received a comprehensive ophthalmological examination, color fundus photographs, fundus auto-fluorescence imaging, and Optical Coherence Tomography (OCT). The CR-T and C-ONL-T were evaluated from standard SD-OCT scans. The PHRa and RPEa were calculated from enface OCT scans (sub RPE slab and photoreceptor slab). The collected OCT parameters were evaluated for possible association with BCVA. Results: The mean macular PHRa and RPEa was 16.16 ± 13.36 and 12.05 ± 12.57 mm2 respectively. The mean CR-T measured 120.78 ± 41.49 μm while the mean C-ONL-T was assessed at 4.60 ± 13.73 μm. BCVA showed the highest correlation with the C-ONL-T ( r = −0.72; p < 0.001) while there was no correlation with the CR-T ( r = −0.17; p = 1.00). Conclusions: Enface OCT permits a rapid and precise quantitative evaluation of the macular PHR and RPE atrophy area in STGD. Nonetheless, the OCT parameter that showed the highest correlation with visual acuity in STGD was the ONL thickness.
Purpose To investigate the anatomical and functional outcomes and specifically, the effect of 360-degree barrier-laser, in pars plana vitrectomy (PPV) for primary pseudophakic rhegmatogenous retinal detachment (PRD). Methods We conducted a single-centre retrospective, continuous and comparative study on eyes that had undergone PPV with focal-retinopexy (laser or cryotherapy) versus 360-laser for PRD repair between 2011–2020 at a single tertiary vitreoretinal centre in the UK. Primary outcomes were single surgery anatomical success (SSAS) rate and final postoperative visual acuity (VA). Multivariable regression covariates for primary re-detachment included age, gender, onset-of-detachment, pre-operative VA, ocular co-morbidities, macula-status, majority inferior (vs superior) PRD, number-of-tears and PRD extent (in clock-hours), 360-laser barricade, and perfluorocarbon liquid (PFCL) use. For VA gain, primary re-detachment was added as a covariate. Results We included 467 eyes with a mean follow-up of 388 (161) days. The SSAS was 444/467 (95.1%) overall, and 351/370 (94.9%) and 93/97 (95.9%) in focal-retinopexy and 360-laser groups, respectively (p = 0.798). Compared to the focal-retinopexy group, the 360-laser group had significantly worse post-operative VA but similar logMAR gain (p = 0.812). A multivariable binary logistic regression found that only PFCL use was linked with increased primary re-detachment (OR:5.32 [p = 0.048]) and 360-laser did not contribute to increased SSAS. A multivariable linear regression analysis showed that poor logMAR gain was significantly associated with better pre-operative logMAR, ocular co-morbidities, greater PRD extent, use of 360-laser and primary re-detachment. However, when excluding macula-off RD (n = 211), 360-laser was no longer significant (p = 0.088). Conclusions Prophylactic 360-laser does not seem to impact on SSAS and functional outcomes following PPV for primary PRD.
29 September 2020 in European Journal of Ophthalmology
Purpose: This case study describes the implantation of a Xen45 Gel Stent in a patient that had previously undergone Descemet stripping automated endothelial keratoplasty (DSAEK). Glaucoma might worsen after corneal transplant, and while medical treatment is the first-line therapy to achieve intraocular pressure (IOP) control, a surgical approach is required when medication does not reach the target IOP. Methods: In 2017, the patient underwent treatment in both eyes with ocular hypotensive eye drops for pseudoexfoliative (PXF) glaucoma. In May 2017, DSAEK was performed on the right eye because of the presence of a pseudophakic bullous keratopathy. An increase in IOP, resistant to medical treatment, was observed after the corneal transplant. In November 2017, a Xen45 Gel Stent was implanted. Results: The patient had a positive outcome with a Xen45 Gel Stent implant in surgical glaucoma treatment after DSAEK. The case demonstrated excellent postoperative IOP control, stable vision and a healthy ocular graft at short-term and long-term follow-ups. Conclusion: Studies with larger numbers of patients in this particular form of therapy are required. Nevertheless, Xen45 Gel Stent implantation appears to be a promising option in preventing or limiting glaucoma in patients who have previously undergone DSAEK. It is a brief, minimally invasive procedure with reduced postoperative inflammation, faster visual recovery and a lower risk of graft damage or hypotony, even in the case of PXF glaucoma.
Purpose The calliper function is used for manual measurements of full thickness macular holes (FTMHs). We aimed to investigate whether a reproducible difference could be detected beyond interobserver variability between two commonly used manufacturers in their manual calliper facility in spectral domain optical coherence tomography (OCT) for metrics related to FTMH. Methods This is a non-interventional, retrospective, observational study. Two independent observers examined 8 eyes (16 OCT) scans and 128 measurements (minimal linear diameter (MLD), basal diameter and hole height on both sides) of FTMHs, taken on Heidelberg Spectralis and Topcon Triton (OCT machines). The interobserver agreement and OCT machine agreement of measurements were analysed by Bland-Altman plots and intraclass correlation coefficient (ICC) analysis. Spectralis and Triton had 125 µm and 50 µm horizontal b-scan spacing, respectively. Results Overall, we report high absolute agreement in interobserver (ICC 0.991 (95% CI 0.985 to 0.995, p<0.001)) and OCT machine (ICC 0.993 (95% CI 0.987 to 0.996, p<0.001)) variability. Lower horizontal resolution in Triton compared with Spectralis leads to interobserver variability, in smaller horizontal measurements. Lower horizontal scanning density in Spectralis lead to relatively large interobserver variation if different reference scans were chosen, and consistently smaller MLD measurements than Triton. Vertical measurements without 1:1 scaling lead to inaccurate exaggerated oblique vertical measurements. Calliper function appears otherwise identically calibrated. Conclusions We report excellent interobserver and OCT machine agreement in measurements. However, the paper shows several factors that could influence the reliability of measurements acquired in eyes with FTMHs, such as the dimension of the hole as well as different image resolution, density scanning protocols or vertical scaling of the OCT machines viewing platform.