Marcin Ryszard Smolarek

Mr. Marcin Ryszard Smolarek

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2023 in Healthcare
Verified
Journal Article
Open access
PDF file
Kamil MichalikKamil Michalik
Kamil Michalik
MSMarcin Ryszard Smolarek
Marcin Ryszard Smolarek
JBJacek Borkowski
Jacek Borkowski
MTMiłosz Tchorowski
Miłosz Tchorowski
NKNatalia Korczuk
Natalia Korczuk
MZMarek Zatoń
Marek Zatoń
This study compared physiological, perceptual and neuroprotective hormone and metabolite responses and changes in coordination as an effect of aerobic exercise with and without a face mask in people with mild symptoms of COVID-19. Forty men took part in this study. Half declared mild symptoms of SARS-CoV-2 infection in the 6 months before the study (Declared) and the other half did not (Non-declared). In a random order, with a 7-day interval, they performed a 30-min walk on a treadmill at a speed of 6 km/h wearing a surgical face mask (Masked) and without it (Unmasked). The heart rate, heart rate variability, oxygen saturation, lactate concentration and rate of perceived exertion were recorded. The reaction time and balance were measured before and after the exercise. The concentrations of brain-derived neurotrophic factor, testosterone, cortisol, epinephrine and antibodies in the blood serum were determined. Physiological and perceptual responses, reaction times, and balance did not differ between the tested conditions. Three-way RM-ANOVA with post hoc Bonferroni analysis revealed lower post-exercise cortisol concentrations in the Masked and Unmasked conditions in both groups (p ≤ 0.001). Asymptomatic infection with this virus is prevalent, and mild COVID-19 causes similar responses to aerobic exercise with a surgical face mask and does not lead to impaired coordination.

4 July 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Kamil MichalikKamil Michalik
Kamil Michalik
MSMarcin Ryszard Smolarek
Marcin Ryszard Smolarek
MNMichał Jakub Nowak
Michał Jakub Nowak
Basilio PueoBasilio Pueo
Basilio Pueo
PZPiotr Zmijewski
Piotr Zmijewski
The Q-LAC analyzer, a portable device employing near-infrared spectroscopy (NIRS), was designed to measure muscle oxygen saturation (SmO2) during physical exercise. This study aimed to assess the reliability of the Q-LAC analyzer in determining SmO2 levels during incremental cycling exercise. Thirteen physically active males (age 28.1 ± 5.3 y; height 181.2 ± 5.7 cm; body mass 79.9 ± 11.1 kg; BMI 24.2 ± 2.4 kg/m2) participated in this study. A submaximal incremental exercise test (SIET) on an electromagnetic cycle ergometer with a seven-day interval was performed twice. SmO2 levels in the vastus lateralis (VL) muscle of the dominant leg were simultaneously recorded using the Q-LAC device during both tests. The study calculated the intraclass correlation coefficient (ICC), the coefficient of variation (CV), the standard error of measurement (SEM), the smallest worthwhile change (SWC), and mean detectable change (MDC). A within-within-subjects ANOVA revealed no statistically significant effects for session (F1,12 = 0.97, p = 0.34, η2 = 0.07) and the interaction between session and workload (F4,48 = 0.19, p = 0.94, η2 = 0.02). ICC values ranged from 0.72 to 0.91. Furthermore, the analysis of CV, SEM, and SWC indicated that SmO2 measurements obtained with the Q-LAC device exhibit good reliability but marginal sensitivity. In conclusion, the portable Q-LAC analyzer provides consistent measurements of muscle oxygen saturation during low-to-moderate-intensity exercise on a cycle ergometer.