To investigate the effects of long-term prestress loss on concrete box girders strengthened with external prestressing, a large-span box girder, in service for over 20 years and strengthened with external prestressing, was monitored for four months. Prestress loss in the longitudinal, vertical, and transverse directions of the box girder was calculated according to Chinese code requirements. Magnetic flux rope force transducers were used to monitor the prestress loss in the external prestressing cables. Fiber Bragg Grating (FBG) sensors were used to monitor deflection changes at the mid-span of the bridge. Finally, the effect of prestress loss in the longitudinal, vertical, and transverse tendons on mid-span deflection was investigated through simulations using ABAQUS software. The results show that instantaneous prestress loss accounts for most of the total loss compared to long-term loss, and that longitudinal prestress loss has the most significant effect on mid-span deflection. The impact of longitudinal prestress loss on deflection before and after strengthening was also compared. The downward deflection and up-ward arch caused by longitudinal tendon prestress loss were reduced after strengthening, con-firming the effectiveness of the external prestressing method.
23 April 2024 in Case Studies in Construction Materials
This study introduces an innovative approach to addressing the plastic shrinkage of ultra-high-performance concrete (UHPC) using an azodicarbonamide (ADC) expansive agent. The influence of ADC on the workability, mechanical properties, and plastic shrinkage of UHPC were systematically investigated. The findings reveal that the addition of ADC generates a substantial number of bubbles within the UHPC slurry, thereby reducing internal frictional resistance and cohesion of the mixture. Consequently, the fluidity and setting time of UHPC were enhanced to varying degrees with increasing ADC content. However, the introduction of these bubbles also reduced the density, leading to a noticeable decline in both compressive and flexural strength, particularly at later stages. Notably, ADC effectively mitigated early shrinkage and increased the vertical expansion rate within the first 24 h. When the ADC dosage ranged from 0.04% to 0.1%, the UHPC remained in an expanded state within 24 h, with a notable difference in expansion rate exceeding 0.02% from 3 to 24 h. Microstructural and pore structure analysis revealed that the ADC generated considerable gas during the mixing process, forming numerous micropores within the UHPC matrix. These dispersed pores contributed to reduced compactness of the UHPC hydrates, resulting in increased pore area, porosity, and average pore diameter.