Reference hemoglobin (Hb) values for the definition of anemia are still largely based on the 1968 WHO Scientific Group report, which established a cutoff value of <13 g/dL for adult men and <12 g/dL for adult nonpregnant women. Subsequent studies identified different normal values according to race and age. Estimated prevalence of anemia on admission in the setting of an acute coronary syndrome (ACS) is between 10% and 43% of the patients depending upon the specific population under investigation. Furthermore, up to 57% of ACS patients may develop hospital-acquired anemia (HAA). Both anemia on admission and HAA are associated with worse short- and long-term mortality, even if different mechanisms contribute to their prognostic impact. Baseline anemia can usually be traced back to preexisting disease that should be specifically investigated and corrected whenever possible. HAA is associated with clinical characteristics, medical therapy and interventional procedures, all eliciting cardiovascular adaptive response that can potentially worsen myocardial ischemia. The intrinsic fragility of anemic patients may limit aggressive medical and interventional therapy due to an increased risk of bleeding, and could independently contribute to worse outcome. However, primary angioplasty for ST elevation ACS should not be delayed because of preexisting (and often not diagnosed) anemia; delaying revascularization to allow fast-track anemia diagnosis is usually feasible and justified in non-ST-elevation ACS. Besides identification and treatment of the underlying causes of anemia, the only readily available means to reverse anemia is red blood cell transfusion. The adequate transfusion threshold is still being debated, although solid evidence suggests reserving red blood cell transfusions for patients with Hb level <8 g/dL and considering it in selected cases with Hb levels of between 8 and 10 g/dL. No evidence supports the use of iron supplements and erythropoiesis-stimulating agents in the setting of ACS.
Background: The Occlutech Atrial Flow Regulator (AFR) is a self-expandable double-disc nitinol device with a central fenestration. Its use has been approved in the adult population with heart failure and described for pulmonary hypertension (PH). Only case reports and small series have been published about its use in the paediatric population and for congenital heart disease (CHD).Objectives: The authors sought to investigate the feasibility, safety, and short-term follow-up of AFR implantation in patients with CHD or children with PH or cardiomyopathy.Methods: This is a multicenter retrospective study involving 10 centers worldwide. Patients of any age with CHD or patients aged < 18 years with PH or cardiomyopathy needing AFR implantation were included.Results: A total of 40 patients underwent AFR implantation. The median age of the population at the time of the procedure was 58.5 months (IQR: 31.5–142.5) and the median weight was 17 kg (IQR: 10–46). A total of 26 (65.0%) patients had CHD, nine (22.5%) children, a cardiomyopathy, and five (12.5%), a structurally normal heart. The implantation success rate was 100%. There were two early and one late device thrombosis. Two patients (5.0%) with dilated cardiomyopathy on extracorporeal membrane oxygenator (ECMO) died during the hospital stay. At a median follow-up of 330 days (IQR: 125–593), 37 (92.5%) patients were alive. At follow-up, 20 patients improved their New York Heart Association (NYHA) class, 12 patients did not change their NYHA class, and one patient with idiopathic PH worsened.Conclusions: AFR implantation in patients with CHD and children with severe PH or cardiomyopathy is promising and seems to have beneficial effects at short-term follow-up.
The CardioMEMS HF System (Abbott, Abbott Park, IL) is the first FDA- and CE-Mark-approved device for monitoring patients with heart failure, significantly reducing hospitalizations and improving the quality of life for NYHA class III non-congenital adult patients. This device, implanted percutaneously, allows the direct monitoring of pulmonary arterial pressure with the wireless transfer of pressure data to the clinician, who can adjust the therapy remotely. Limited experience exists regarding its use in patients with congenital heart disease (CHD). CardioMEMS device implantation is feasible and safe in selected adults and children with CHD. The potential of the device to reduce heart failure hospitalizations in this population is enormous, but further multi-center studies are needed to demonstrate its efficacy.
Background: Multi-system inflammatory syndrome in children and Kawasaki disease have overlapping clinical features but comparative echocardiographic studies are lacking.Methods: We reviewed echocardiography findings of all multi-system inflammatory syndrome cases between 1st April and 31st July, 2020 and typical Kawasaki disease patients with coronary arteries abnormalities consecutively followed between 1st October, 2016 and June 30th, 2019.Results: We included 40 multi-system inflammatory syndrome children (25 males, 62.5%) and 45 Kawasaki disease patients (31 males, 68.9%) at a mean age of 6.4 years old and 8 years old, respectively. Four out of 40 multi-system inflammatory syndrome children had coronary arteries abnormalities. Left ventricle ejection fraction was normal in both groups. Global longitudinal strain was normal although Kawasaki disease group had significantly lower values (–20.0 versus –21.7%; p = 0.02). Basal segments were the most affected in Kawasaki disease patients with significant differences in the basal anterior, anterolateral, and anteroseptal strain: –18.2 versus –23.0% (p = 0.002), –16.7 versus –22.0% (p < 0.001), –16.7 versus –19.5% (p = 0.034), respectively. The basal anterolateral and anteroseptal segments in Kawasaki disease patients were the only ones with an absolute reduction of longitudinal strain (–16.7% both) consistent with the greater left main coronary involvement in this cohort.Conclusions: Our findings are consistent with the transient cardiac involvement in multi-system inflammatory syndrome, as opposed to the subtle and chronic myocardial involvement in Kawasaki disease children with coronary arteries abnormalities. We speculate that the mechanism of cardiac impairment in the few multi-system inflammatory syndrome children with reduced global longitudinal strain is not related to coronary arteries abnormalities.
Transcatheter closure of perimembranous ventricular septal defect is an alternative to surgery in selected small to medium defects with a reasonable distance between the defect and the aortic or tricuspid valves. Surgical closure is generally preferred for large defects with an inlet to outlet extension, aortic malalignment, or deficient aortic rim. We report two successful cases of percutaneous closure of large perimembranous ventricular septal defects with inlet to outlet extension using an Amplatzer Vascular Plug-II via a retrograde approach. Transcatheter closure of large perimembranous ventricular septal defect with inlet to outlet extension is feasible and facilitated by the characteristics of the Amplatzer Vascular Plug-II device and the specific implantation technique.