Pietro Picerno

Prof. Pietro Picerno

School of Pharmacy, University of Camerino, Camerino, Italy
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2016 in Expert Review of Medical Devices
Verified
Journal Article
Closed access
Marco IosaMarco Iosa
Marco Iosa
Pietro PicernoPietro Picerno
Pietro Picerno
SPStefano Paolucci
Stefano Paolucci
Giovanni MoroneGiovanni Morone
Giovanni Morone
Introduction: The present review aims to provide an overview of the most common uses of wearable inertial sensors in the field of clinical human movement analysis. Areas covered: Six main areas of application are analysed: gait analysis, stabilometry, instrumented clinical tests, upper body mobility assessment, daily-life activity monitoring and tremor assessment. Each area is analyzed both from a methodological and applicative point of view. The focus on the methodological approaches is meant to provide an idea of the computational complexity behind a variable/parameter/index of interest so that the reader is aware of the reliability of the approach. The focus on the application is meant to provide a practical guide for advising clinicians on how inertial sensors can help them in their clinical practice. Expert commentary: Less expensive and more easy to use than other systems used in human movement analysis, wearable sensors have evolved to the point that they can be considered ready for being part of routine clinical routine.


1 November 2008 in Gait & Posture
Verified
Journal Article
Closed access
Pietro PicernoPietro Picerno
Pietro Picerno
ACAndrea Cereatti
Andrea Cereatti
ACAurelio Cappozzo
Aurelio Cappozzo

1 January 2011 in Journal of Sports Sciences
Verified
Journal Article
Closed access
Pietro PicernoPietro Picerno
Pietro Picerno
Valentina CamomillaValentina Camomilla
Valentina Camomilla
Laura CapranicaLaura Capranica
Laura Capranica
The aim of this study was to validate a wearable inertial measurement unit (IMU), containing a 3D accelerometer and gyroscope, for the estimation of countermovement jump height. The absolute vertical acceleration of the IMU positioned on the back of the participant at L5 level, compensated for trunk rotations, was used to obtain jump height by applying the equation of free-fall to the motion of the IMU. The methodology was tested on 28 participants performing five countermovement jumps each. A reference value for this quantity was obtained using stereophotogrammetry (35.4 cm, s = 4.9). Jump height scores obtained using the proposed methodology (35.9 cm, s = 5.5) presented no significant difference with respect to stereophotogrammetry (P = 0.61). A low bias of 0.6 cm confirmed the accuracy of the estimate, which also showed a high (r = 0.87) and significant (P < 0.0001) correlation with reference values. Furthermore, without compensating accelerations for trunk rotation, jump height was largely underestimated (P < 0.0001) (bias: -12.7 cm) and poorly associated (r = 0.31) with stereophotogrammetry. The results of this study show that the estimation of jump height using inertial sensors leads to accurate results when the measured accelerations are corrected for trunk rotations.

1 April 2012 in Journal of Biomechanics
Verified
Journal Article
Closed access
Elena BergaminiElena Bergamini
Elena Bergamini
Pietro PicernoPietro Picerno
Pietro Picerno
HPHelene Pillet
Helene Pillet
FNFrançoise Natta
Françoise Natta
PTPatricia Thoreux
Patricia Thoreux
Valentina CamomillaValentina Camomilla
Valentina Camomilla

1 March 2011 in Gait & Posture
Verified
Journal Article
Closed access
Pietro PicernoPietro Picerno
Pietro Picerno
ACAndrea Cereatti
Andrea Cereatti
ACAurelio Cappozzo
Aurelio Cappozzo