High-touch surfaces contributing to infection transmission are particularly concerning in the ophthalmology clinic where frequent contact exists between ophthalmologists and various ophthalmic instruments. Areas of surface contamination from an ophthalmologist’s contact with the slit lamp environment were identified using ultraviolet fluorescence as a surrogate for pathogen contamination. Ultraviolet fluorescent product was applied on the ophthalmologist’s hands after thorough hand washing to indicate the contamination that may be derived from multiple sources in the ophthalmology clinic, such as touching the patient or the patient’s folder during eye examinations and transfers. The ophthalmology clinic was run normally, with the ophthalmologist wiping down patient-contact surfaces on the slit lamp and performing thorough hand hygiene after every patient. Using ultraviolet black light, persistence of surface contamination in the slit lamp environment was identified and evaluated across five days. High-touch surfaces of suboptimal disinfection were inclined towards those touched only by the ophthalmologist, for example: joystick and chin-rest adjustment knob, as compared to patient-contact surfaces. Persistent contamination on the same surfaces revealed inefficacy of current hand hygiene and clinical disinfection practices. This poses a significant risk for pathogen transmission and underscores the importance of including these specific clinician high-touch surfaces in existing cleaning protocols.

22 July 2024 in Hygiene
Verified
Journal Article
Open access
PDF file
BLBerdjette Yu You Lau
Berdjette Yu You Lau
CCCassandra Chan
Cassandra Chan
XNXin Le Ng
Xin Le Ng
DLDawn K. A. Lim
Dawn K. A. Lim
BLBlanche Lim
Blanche Lim
CLChris Lim
Chris Lim
In light of the close contact between patient and clinician during ophthalmic examinations and the multiple opportunities for pathogen transmission, we identified and evaluated potential pathogen transmission routes through high-touch surfaces in an outpatient ophthalmology clinic. A circuit simulation was performed to replicate a patient’s journey through an ophthalmology clinic with various stations. Fluorescent oil and powder were applied to the hands of Simulated Patient A who went through the circuit. Routine disinfection of surfaces in the slit lamp environment and hand hygiene by the ophthalmologist were conducted prior to Simulated Patient B going through the same circuit with untagged hands. Ultraviolet black light was used to identify fluorescent marker contamination after Simulated Patient B completed the circuit. Fluorescent marker contamination was found on the hands of all the simulated patients and staff, various items of the simulated patients, multiple equipment surfaces—particularly the ophthalmologist’s working table and slit lamp environment—and miscellaneous objects like appointment cards and files. Fluorescent marker contamination on Simulated Patient B’s untagged hands despite proper hand hygiene being performed prior suggests suboptimal surface disinfection following Simulated Patient A’s circuit. Through this pilot study, we recognised the key role that ophthalmic high-touch surfaces play in fomite transmission and that thorough disinfection of high-touch surfaces is essential on top of proper hand hygiene. With the contact sequences delineated in this pilot study, specific cues for hand hygiene and surface disinfection may be implemented at suitable intervals during contact with high-touch surfaces. Environmental decontamination adjuncts could also be considered to reinforce surface disinfection.