Ivan Lazovic

Prof. Ivan Lazovic


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015 in Environmental Pollution
Verified
Journal Article
Closed access
MJMilena Jovašević-Stojanović
Milena Jovašević-Stojanović
ABAlena Bartonova
Alena Bartonova
DTDušan Branislav Topalović
Dušan Branislav Topalović
ILIvan Lazovic
Ivan Lazovic
BPBoris Pokrić
Boris Pokrić
ZRZoran Ristovski
Zoran Ristovski

1 December 2014 in Energy
Verified
Journal Article
Closed access
VTValentina Turanjanin
Valentina Turanjanin
BVBiljana Vučićević
Biljana Vučićević
MJMarina Jovanović
Marina Jovanović
NMNikola Mirkov
Nikola Mirkov
ILIvan Lazovic
Ivan Lazovic

1 January 2016 in Thermal Science
Verified
Journal Article
Open access
PDF file
ILIvan Lazovic
Ivan Lazovic
ŽSŽarko M. Stevanović
Žarko M. Stevanović
MJMilena Jovašević-Stojanović
Milena Jovašević-Stojanović
MŽMarija Živković
Marija Živković
MBMiloš J. Banjac
Miloš J. Banjac
Previous studies have shown that poorly ventilated classrooms can have negative impact on the health of children and school staff. In most cases, schools in Serbia are ventilated naturally. Considering their high occupancy, classroom air quality test determines the level of air pollution, after which it is possible to implement corrective measures. The research presented in this study was conducted in four schools which are located in different areas and have different architecture designs. Measurements in these schools have been performed during the winter (heating season) and spring (non-heating season) and the following results were presented: indoor air temperature, relative humidity and carbon dioxide concentration. These results show that the classroom average concentration of carbon dioxide often exceeds the value of 1500 ppm, during its full occupancy, which indicates inadequate ventilation. Measurement campaigns show that carbon dioxide concentration increased significantly from non-heating to heating season in three of the four schools. Analysis of measurements also determined high correlation between relative humidity and carbon dioxide concentration in all schools in winter season. This fact may constitute a solid basis for the fresh air supply strategy.

1 January 2015 in Chemical Industry and Chemical Engineering Quarterly
Verified
Journal Article
Open access
PDF file
ILIvan Lazovic
Ivan Lazovic
MJMilena Jovašević-Stojanović
Milena Jovašević-Stojanović
MŽMarija Živković
Marija Živković
VTViša M Tasić
Viša M Tasić
ZSZarko Stevanovic
Zarko Stevanovic
Indoor air quality (IAQ) is very important for children health and well-being, since children are particularly vulnerable and sensitive on presence of air pollutants. This study was performed in two naturally ventilated schools located in the same municipality. First school is located in urban area, at residential - industrial site, while the other school is situated in rural area. School buildings were chosen based on their urban environment features. The measurements were carried out in heating as well as in non-heating period in duration of five consecutive working days. The objective of the study was to analyze IAQ in the classrooms with special emphasis on levels and diurnal variations of particulate matter (PM10 and PM2.5), carbon dioxide (CO2) and nitrogen dioxide (NO2) in occupied and unoccupied school classrooms. In this paper, the CO2 concentrations were measured at both indoor and outdoor environments. Concentrations of CO2 higher than 1000 ppm were regularly detected in the classrooms during teaching hours. Indoor concentrations of PM10 were not exceeded the guideline, daily average, value of 50 ?g/m3. Concentrations of PM2.5 were exceeded the guideline, daily average, value of 25 ?g/m3 in both school during heating period. Concentrations NO2 were not exceeded the guideline value of 200 ?g/m3. Ventilation rates were calculated and compared with the prescribed limits. In both occupied and unoccupied periods high correlation between CO2 and PM concentrations was determined.

1 January 2015 in Chemical Industry and Chemical Engineering Quarterly
Verified
Journal Article
Open access
PDF file
MŽMarija Živković
Marija Živković
MJMilena Jovašević-Stojanović
Milena Jovašević-Stojanović
ACAnka Cvetkovic
Anka Cvetkovic
ILIvan Lazovic
Ivan Lazovic
VTViša M Tasić
Viša M Tasić
IGIvan Grzetic
Ivan Grzetic
This study investigated seasonal variation of PAHs and their partition between gas and particulate-bounded phases in indoor and outdoor air in 4 schools in Serbia located at different locations. The sampling campaigns were conducted during one workweek at each school successively. Campaigns were conducted in schools during heating and non-heating seasons in December 2011 and June 2012. Seasonal variations of gas and particle-bounded PAHs concentrations were observed with higher levels during heating season. The highest total PAH values were associated with the gas phase in both sampling periods. The total PAHs concentration at indoor and at the outdoor sites, during heating season, ranged from 88.45 to 447.72 ng/m3 and 201.69 to 1017.15 ng/m3, respectively. During non-heating season, the total PAHs concentration ranged from 36.91 to 271.57 ng/m3 in indoor environment and 27.00 to 132.32 ng/m3 in outdoor environment. Most of the I/O ratios were less than 1, which indicated that the indoor PAHs were mostly from outdoor sources. The use of diagnostic ratio showed that traffic emission and coal combustion are the major sources of PAHs. Only the diagnostic ratios for the school, located near the industrial area, showed significant deviation compared to other schools.

21 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DSDanka B. Stojanović
Danka B. Stojanović
DKDuška Kleut
Duška Kleut
Miloš DavidovićMiloš Davidović
Miloš Davidović
MŽMarija Živković
Marija Živković
URUzahir Ramadan Ramadani
Uzahir Ramadan Ramadani
MJMilena Jovašević-Stojanović
Milena Jovašević-Stojanović
Conventional air quality monitoring networks typically tend to be sparse over areas of interest. Because of the high cost of establishing such monitoring systems, some areas are often completely left out of regulatory monitoring networks. Recently, a new paradigm in monitoring has emerged that utilizes low-cost air pollution sensors, thus making it possible to reduce the knowledge gap in air pollution levels for areas not covered by regulatory monitoring networks and increase the spatial resolution of monitoring in others. The benefits of such networks for the community are almost self-evident since information about the level of air pollution can be transmitted in real time and the data can be analysed immediately over the wider area. However, the accuracy and reliability of newly produced data must also be taken into account in order to be able to correctly interpret the results. In this study, we analyse particulate matter pollution data from a large network of low-cost particulate matter monitors that was deployed and placed in outdoor spaces in schools in central and western Serbia under the Schools for Better Air Quality UNICEF pilot initiative in the period from April 2022 to June 2023. The network consisted of 129 devices in 15 municipalities, with 11 of the municipalities having such extensive real-time measurements of particulate matter concentration for the first time. The analysis showed that the maximum concentrations of PM2.5 and PM10 were in the winter months (heating season), while during the summer months (non-heating season), the concentrations were several times lower. Also, in some municipalities, the maximum values and number of daily exceedances of PM10 (50 μg/m3) were much higher than in the others because of diversity and differences in the low-cost sensor sampling sites. The particulate matter mass daily concentrations obtained by low-cost sensors were analysed and also classified according to the European AQI (air quality index) applied to low-cost sensor data. This study confirmed that the large network of low-cost air pollution sensors can be useful in providing real-time information and warnings about higher pollution days and episodes, particularly in situations where there is a lack of local or national regulatory monitoring stations in the area.