Biofilm formation on implantable medical devices is a major impediment to the treatment of nosocomial infections and promotes local progressive tissue destruction. Staphylococcus epidermidis infections are the leading cause of biofilm formation on indwelling devices. Bacteria in biofilms are highly resistant to antibiotic treatment, which in combination with the increasing prevalence of antibiotic resistance among human pathogens further complicates treatment of biofilm-related device infections. We have developed a novel plasma coating technology. Trimethylsilane (TMS) was used as a monomer to coat the surfaces of 316L stainless steel and grade 5 titanium alloy, which are widely used in implantable medical devices. The results of biofilm assays demonstrated that this TMS coating markedly decreased S. epidermidis biofilm formation by inhibiting the attachment of bacterial cells to the TMS-coated surfaces during the early phase of biofilm development. We also discovered that bacterial cells on the TMS-coated surfaces were more susceptible to antibiotic treatment than their counterparts in biofilms on uncoated surfaces. These findings suggested that TMS coating could result in a surface that is resistant to biofilm development and also in a bacterial community that is more sensitive to antibiotic therapy than typical biofilms.
6 February 2014 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
The objective of this study was to evaluate the biocompatibility of trimethylsilane (TMS) plasma nanocoatings modified with NH3/O2 (2:1 molar ratio) plasma post-treatment onto cobalt chromium (CoCr) L605 alloy coupons and stents for cardiovascular stent applications. Biocompatibility of plasma nanocoatings was evaluated by coating adhesion, corrosion behavior, ion releasing, cytotoxicity, and cell proliferation. Surface chemistry and wettability were studied to understand effects of surface properties on biocompatibility. Results show that NH3/O2 post-treated TMS plasma nanocoatings are hydrophilic with water contact angle of 48.5° and have a typical surface composition of O (39.39 at.%), Si (31.92 at.%), C (24.12 at.%), and N (2.77 at.%). The plasma nanocoatings were conformal to substrate surface topography and had excellent adhesion to the alloy substrates, as assessed by tape test (ASTM D3359), and showed no cracking or peeling off L605 stent surfaces after dilation. The plasma nanocoatings also improve the corrosion resistance of CoCr L605 alloy by increasing corrosion potential and decreasing corrosion rates with no pitting corrosion and no mineral adsorption layer. Ion releasing test revealed that Co, Cr, and Ni ion concentrations were reduced by 64–79%, 67–69%, and 57–72%, respectively, in the plasma-nanocoated L605 samples as compared to uncoated L605 control samples. The plasma nanocoatings showed no sign of cytotoxicity from the test results according to ISO 10993-05 and 10993-12. Seven-day cell culture demonstrated that, in comparison with the uncoated L605 control surfaces, the plasma nanocoating surfaces showed 62 ± 7.3% decrease in porcine coronary artery smooth muscle cells (PCASMCs) density and had comparable density of porcine coronary artery endothelial cells (PCAECs). These results suggest that TMS plasma nanocoatings with NH3/O2 plasma post-treatment possess the desired biocompatibility for stent applications and support the hypothesis that nanocoated stents could be very effective for in-stent restenosis prevention.
Excessive or persistent infection is a major contributing factor in impeding chronic wound healing. Wound bed preparations using antiseptics do not necessarily target the entire bacterial spectrum, and the highly proliferating granulation tissue may be sensitive to the cytotoxic effects, impairing tissue repair. Non-thermal gas atmospheric pressure plasmas are partially ionized gases that contain highly reactive particles while the gas phase remains near room temperature, thus having the capability of accessing small irregular cavities and fissures and killing bacteria because of the diffusive nature of gas phase plasma species that are chemically reactive, providing an ideal approach to topical wound disinfection. A non-thermal plasma brush device of novel design has been developed that is suitable for clinical application in the disinfection of oral and wound bacteria. In vivo studies have indicated that the plasma brush treatment rendered no harmful effect on healthy skin or tissues, while it could improve wound healing in Pseudomonas aeruginosa biofilm infected wounds exposed to an optimized treatment with argon plus 1% nitrogen (Ar + N2) plasma.
19 July 2023 in Journal of Biomedical Materials Research Part A
A plasma cross-linking process was employed to improve the surface lubricity of different types of biomaterials, including stainless steel (SS), nitinol, polyethylene and nylon. To investigate the influence of monomers containing double bonds on top-layer cross-linking of poly(ethylene oxide) compound (PEOC), five different monomers, N-trimethylsilyl-allylamine (TMSAA), ethylene, propylene, allyl alcohol and ethane, were used in the study to produce a cross-linked coating layer on sample surfaces. Before the plasma cross-linking, samples underwent plasma treatment followed by wet chemical coating. The plasma treatment consists of plasma etching in NH3/O2, Tetramethylcyclo-tetrasiloxane (TMCTS) coating and TMSAA grafting. The wet coating process includes dip-coating in a solution of poly(oxyethylene)-compound bis(1-hydroxy-benzotriazolyl carbonate) (HPEOC), then dip-coating in a solution of PEOC. By application of plasma processing, HPEOC and PEOC wet coating to sample surfaces, the lubricity was increased...