亦可 郭

Ms. 亦可 郭


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DJDazuo Jiang
Dazuo Jiang
HZHuanqing Zou
Huanqing Zou
亦郭亦可 郭
亦可 郭
TFTian Fuqiang
Tian Fuqiang
HLHongqi Liu
Hongqi Liu
YYYufeng Yin
Yufeng Yin
When the electric locomotive pantograph is dropping, the interruption of pantograph catenary contact causes electromagnetic oscillation and arcing. The frequent arc burning that occurs due to charge accumulation results in the amplitude of overvoltage increasing gradually, posing a threat to locomotive high-voltage equipment. However, the physical mechanisms and characteristics of overvoltage are still unclear. This paper proposes a simulation model of operating overvoltage due to a dropping pantograph based on the pantograph–catenary arc and variable capacitance. Distributed RLC electromagnetic oscillation is considered, which allows the real-time calculation of arc resistance and capacitance. Under the same working conditions, the error between the simulation and test results is less than 4.0%, which proves the credibility of the model. The variation law of overvoltage under different dropping speeds or catenary phases was investigated, which shows the max amplitude is 298.20 kV and steepness is 2096.80 kV/μs at 0.30 m/s speed. The waveform shows the characteristics of high amplitude and high steepness, similar to very fast transient overvoltage (VFTO). There is a sinusoidal relationship between the catenary phase and overvoltage amplitude. The closer the catenary phase to 90°, the higher the overvoltage amplitude. The research has important guiding significance for the overvoltage formation mechanism of a traction power supply system and the insulation coordination design of high-voltage equipment.

19 October 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
亦郭亦可 郭
亦可 郭
TFTian Fuqiang
Tian Fuqiang
宏刘宏琦 刘
宏琦 刘
YYYufeng Yin
Yufeng Yin
Operating overvoltage occurs when the pantograph or main breaker of an electric locomotive is operated, which is prone to causing insulation failure of high-voltage equipment. The HXD1 electric locomotive is taken as the research object in this paper to explore the characteristics and influencing factors of operating overvoltage. Under pantograph lifting, main breaker closing, main breaker opening, and pantograph dropping, operating overvoltage waveform in the high-voltage system is recorded by a high-speed oscilloscope and resistance–capacitance voltage divider to analyze the overvoltage characteristics and distribution law. Tested data show that the amplitude of operating overvoltage is in the range of 80 to 330 kV with ultra-high steepness, which is similar to the Very Fast Transient Overvoltage (VFTO) in power systems. The maximum overvoltage during the entire test occurred during the main breaker closing and its amplitude is 328.60 kV with a steepness of 4.21 × 104 kV/μs. The max overvoltage of the other operations (pantograph lifting, main breaker opening, and pantograph dropping) are 280.60 kV, 194.73 kV, and 305.56 kV with ultra-high steepness. High-amplitude overvoltage is predominantly located at the pantograph, while the low-amplitude sort is mainly observed around other high-voltage equipment. The result indicates that operating overvoltage belongs to ultra-fast transient overvoltage and its amplitude and steepness are higher than existing research.