Controller area network (CAN) protocol is an efficient standard enabling communication among electronic control units (ECUs). However, the CAN bus is vulnerable to malicious attacks because of a lack of defense features. In this article, a novel vehicle intrusion detection system (IDS) is developed. The challenge is that existing techniques of IDSs rarely consider attacks with small-batch, which are characterized by their small attack scale and concealed attack patterns, posing a significant threat to driving safety. To solve this problem, we developed an algorithm model that merges multidimensional long short-term memory (MD-LSTM) and self-attention mechanism (SAM), shortly named MULSAM. The MULSAM model was compared with other baseline models, including stacked long short-term memory (LSTM), MD-LSTM, etc. Experiments show that our approach has the best-detection accuracy (98.98%) and training stability. Further, to speed up the inference of MULSAM on edge, the hardware accelerator is implemented on FPGA devices using technologies, such as parallelization, modular, pipeline, and fixed-point quantization. Experiments show that our FPGA-based acceleration scheme has a better-energy efficiency than the CPU platform. Even with a certain degree of quantification, the acceleration model for MULSAM still displays a high-detection accuracy of 98.81% and a low latency of 1.88 ms.
Accurate and prompt determination of fire types is essential for effective firefighting and reducing damage. However, traditional methods such as smoke detection, visual analysis, and wireless signals are not able to identify fire types. This paper introduces FireSonic, an acoustic sensing system that leverages commercial speakers and microphones to actively probe the fire using acoustic signals, effectively identifying fire types. By incorporating beamforming technology, FireSonic first enhances signal clarity and reliability, thus mitigating signal attenuation and distortion. To establish a reliable correlation between fire type and sound propagation, FireSonic quantifies the heat release rate (HRR) of flames by analyzing the relationship between fire-heated areas and sound wave propagation delays. Furthermore, the system extracts spatiotemporal features related to fire from channel measurements. The experimental results demonstrate that FireSonic attains an average fire type classification accuracy of and a detection latency of less than 400 ms, satisfying the requirements for real-time monitoring. This system significantly enhances the formulation of targeted firefighting strategies, boosting fire response effectiveness and public safety.
22 August 2024 in IEEE Transactions on Industrial Informatics
Quantized neural networks (QNNs) have become a standard operation for efficiently deploying deep learning models on hardware platforms in real application scenarios. An empirical study on German traffic sign recognition benchmark (GTSRB) dataset shows that under the three white-box adversarial attacks of fast gradient sign method, random + fast gradient sign method and basic iterative method, the accuracy of the full quantization model was only 55%, much lower than that of the full precision model (73%). This indicates the adversarial robustness of the full quantization model is much worse than that of the full precision model. To improve the adversarial robustness of the full quantization model, we have designed an adversarial attack defense platform based on field-programmable gate array (FPGA) to jointly optimize the efficiency and robustness of QNNs. Various hardware-friendly techniques such as adversarial training and feature squeezing were studied and transferred to the FPGA platform based on the designed accelerator of QNN. Experiments on the GTSRB dataset show that the adversarial training embedded on FPGA can increase the model's average accuracy by 2.5% on clean data, 15% under white-box attacks, and 4% under black-box attacks, respectively, demonstrating our methodology can improve the robustness of the full quantization model under different adversarial attacks.
Accurate and prompt determination of fire types is essential for effective firefighting and reducing damages. However, traditional methods such as smoke detection, visual analysis, and wireless signals pose unavailability in identifying fire types. This paper introduces FireSonic, an acoustic sensing system that leverages commercial speakers and microphones to actively probe the fire using acoustic signals, effectively identifying indoor fire types. By incorporating beamforming technology, FireSonic first enhances signal clarity and reliability, thus mitigating signal attenuation and distortion. To establish a reliable correlation between fire types and sound propagation, FireSonic quantifies the Heat Release Rate (HRR) of flames by analyzing the relationship between fire heated areas and sound wave propagation delays. Furthermore, the system extracts spatiotemporal features related to fire from channel measurements. Experimental results demonstrate that FireSonic attains an average fire type classification accuracy of 95.5% and a detection latency of less than 400 ms, satisfying the requirements for real-time monitoring. This system significantly enhances the formulation of targeted firefighting strategies, boosting fire response effectiveness and public safety.