This article proposes new values and geospatial models of winter and summer external design temperatures for designing buildings’ heating, ventilation, and air-conditioning (HVAC) systems. The climatic design parameters applicable in Poland for the sizing of these installations are approximately 50 years old and do not correspond to Poland’s current climate. New values of climatic design parameters were determined following the methods described in European standards and the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Handbook of Fundamentals. The determined climatic design parameters, particularly the winter and summer external design temperatures, were compared with those currently in force by law in Poland. The external air design dry-bulb temperatures presented in the article were developed based on meteorological and climatic data from the years 1991–2020 from two data sources: synoptic data from the Institute of Meteorology and Water Management (IMWM) in Poland and reanalysis models of the ERA5 database of the European Centre for Medium-Range Weather Forecasts (ECMWF). According to ASHRAE, with 99.6% and 0.4% frequency of occurrence, external air design dry-bulb temperatures for winter and summer were used to develop mathematical geospatial models of external design temperatures for the Central Europe area with Poland’s territory in the centre part. Scattered data from 667 meteorological stations were interpolated to 40,000 uniform mesh points using a biharmonic spline interpolation method to develop these models. Linear regression and ANOVA analysis for the ERA5-generated data from 900 checkpoint data items were used to estimate the correctness of these models. Verified models were used to calculate winter and summer external design temperature isolines presented together with colour space representation on Mercator projected maps of Central Europe.
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
This paper presents the airflow characteristics of humidity-sensitive air inlet. This type of air inlets and exhausts are often part of demand control ventilation, especially in dwellings where humidity is an important indicator of ventilation needs. Humidity-controlled ventilation is one of the simplest implementations of smart ventilation, even in the case of a natural ventilation system. This type of solution leads to decreased energy consumption and increases the indoor air quality. A description of airflow characteristics is crucial for resolving these issues. The presented characteristics are based on the measurements of the indoor/outdoor relative humidity, airflow, and pressure drop across the air inlet. The characteristics are described based on a general power law flow model (V = C·∆pn), which is the most suitable, for example, for the CONTAM multizone indoor air quality and ventilation analysis computer program. The characteristics include relationships between the indoor and outdoor relative humidity, hysteresis, and dynamic changes in indoor relative humidity. The simplified and complex formulas are presented. The accuracy of the airflow calculation based on these formulas is discussed.