Depth of field (DOF) and resolution are mutually restricted in integral imaging (II) display. To overcome the trade-offs, we propose an II display system that simultaneously enhances the DOF and resolution. The system consists of a transmissive mirror device (TMD), a semi-transparent mirror (STM), and two II display units. Each II display unit consists of a 4K display screen and a micro-lens array (MLA). Benefiting from the parallel placement of the TMD and the STM, two central depth planes are reconstructed, which effectively enhances the DOF. Meanwhile, the resolution in the overlapping DOF region is increased to two times due to the interpolation of the light field information from two II display units. The impact of the distance between the two II display units and the TMD on the 3D image quality is analyzed. In geometric optics, a distance between the II two display units and the TMD is optimized to eliminate ghost images. In wave optics, a distance is optimized to eliminate 3D pixel gaps by exploiting the diffraction effect of the TMD. Both the geometric and wave optics are considered simultaneously to obtain a high-quality 3D image without ghost images and 3D pixel gaps. A DOF and resolution-enhanced II display system is developed, and the experimental results verify its feasibility.
We propose a large viewing angle integral imaging 3D display system based on a symmetrical compound lens array (SCLA). The display system comprises a high-resolution 2D display panel, an SCLA, and a light shaping diffuser. The high-resolution 2D display panel presents an elemental image array, the SCLA modulates the light rays emitted from the 2D display panel to form 3D images in space, and the light shaping diffuser eliminates the gaps between 3D pixels of the 3D images. We find that the lateral aberration is a crucial factor that affects the resolution of the reconstructed 3D image. The symmetrical structure of the SCLA enables a reduced focal length and the elimination of lateral aberration, improving the viewing angle and the 3D image resolution simultaneously. The experimental results confirm that the proposed display system increases the viewing angle to 68.6°, achieving a comparable resolution of the full field of view while maintaining a simple structure.
We propose a system to eliminate the graininess of an integral imaging 3D display by using a transmissive mirror device (TMD). The proposed system consists of a 2D display, a micro-lens array (MLA), and a TMD. The TMD comprises square apertures with mirror-reflective inner wall. The light rays pass through the square aperture to form a diffraction spot, and the diffraction light intensity has a Sinc-function distribution. Therefore, the TMD can be used as an optical low-pass filter. In a certain imaging range, the mainlobe of the Sinc-function distribution is almost unchanged. The TMD has the property of a volumetric optical low-pass filter. It can interpolate the interval between discrete 3D pixels. Therefore, the TMD can be used to eliminate the graininess. The resolution of the 3D image is improved by 2.12 times. The experimental results verify the feasibility of the proposed system.