The Yarlung Zangbo River (YZR) is the largest river system in the Tibetan Plateau, and its basin is one of the centers of human economic activity in Tibet. Large uncertainties exist in several previous climate change studies in this basin because of limited climate observations. In this paper, we used a meteorological drought index (Standardized Precipitation Evapotranspiration Index, SPEI) and a newly-released gridded climate forcing dataset based on high-quality climate station data to re-evaluate climate change in the YZR Basin during the period of 1961–2014. Results showed that precipitation experienced a statistically insignificant increasing trend at a rate of 6.32 mm/10 years, and its annual mean was 512.40 mm. The basin was sensitive to climate change in terms of the air temperature that significantly increased at the rate of 0.32 °C/10 years. This warming rate was obviously larger than that in many other regions. Analysis of SPEI showed that the basin had no obvious statistical trends in the number of dry/wet episodes, but the severity of dry episode aggravated in terms of duration and magnitude. This study provides a reliable analysis of climate change in the YZR Basin, and suggests this large Tibetan river basin is sensitive to climate change.
6 December 2016 in Environmental Science and Pollution Research
The present work describes the optimization and validation of a highly selective and sensitive analytical method using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE LC-MS/MS) for the determination of some frequently prescribed pharmaceuticals in urban wastewater received and treated by Sharjah sewage treatment plant (STP). The extraction efficiency of different SPE cartridges was tested and the simultaneous extraction of pharmaceuticals was successfully accomplished using hydrophilic-lipophilic-balanced reversed phase Waters® Oasis HLB cartridge (200 mg/ 6 mL) at pH 3. The analytes were separated on an Aquity BEH C18 column (1.7 µm, 2.1 mm × 150 mm) using gradient elution and mass spectrometric analysis were performed in multiple reactions monitoring (MRM) selecting two precursor ions to produce ion transition for each pharmaceutical using positive electrospray ionization (+ESI) mode. The correlation coefficient values in the linear calibration plot for each target compound exceeded 0.99 and the recovery percentages of the investigated pharmaceuticals were more than 84%. Limit of detection (LOD) varied between 0.1–1.5 ng/L and limit of quantification (LOQ) was 0.3–5 ng/L for all analytes. The precision of the method was calculated as the relative standard deviation (RSD%) of replicate measurements and was found to be in the ranges of 2.2% to 7.7% and 2.2% to 8.6% for inter and intra-day analysis, respectively. All of the obtained validation parameters satisfied the requirements and guidelines of analytical method validation.
2 December 2010 in Environmental Monitoring and Assessment