In industrial plants with dynamically varying load profiles, the problem of increased charges for over-contracted reactive power consumption is very common. To eliminate these charges, reactive power compensation systems are used. This article presents a case study of an automatic reactive power compensation system in an underground mine where a thyristor hoisting machine is used. To reduce the higher current harmonics of the hoisting machine and compensate for the reactive power of the PCC (Point of Common Coupling), the main reactive power automatic compensation system and an ASVG (Advanced Static Var Generator) with a nonstandard control loop were used. The article considers aspects of the operation of the ASVG, locally with the hoisting machine, and also as a master-controlled device that is part of the reactive power automatic compensation system. This part of the article is based on measurements taken in a mine. The reactive power automatic compensation system considered in this article has been successfully implemented, improving PQ (Power Quality) and eliminating additional overcompensation charges.
The paper presents idea and practical implementation of a medium voltage synchronous drive with a voltage source inverter in the stator circuit and a microprocessor controlled unit for excitation supply. Construction of both devices was presented, and methods of their cooperation were described. Selected start-up methods of large power synchronous motors were presented. Exemplary realization was discussed. Measurement results of the direct full-voltage start-up and frequency start-up of a real 1.25 MW 6 kV fan drive system were compared and discussed.
The paper presents the problems of the influence of a high power thyristor hoisting machine on the mine's power supply grid. The results of the real object measurements when the machine is powered from a 12-pulse rectifier with common, symmetrical firing angle control are presented. A comparative analyses were carried out in terms of reactive power and higher harmonics for symmetrical and asymmetric firing angle of thyristors based on simulation tests. The influence of the rectifier control method on the operating conditions of the automatic reactive power compensation system was indicated. Practical aspects, not included in the simulation model, have been emphasized.
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informujące swoich czytelników o najnowszych osiągnięciach naukowych i nowoczesnych rozwiązaniach technicznych w Polsce i na świecie, popularyzuje problemy techniczne oraz poszerza wiedzę i kulturę techniczną.