Saleh Alzahrani

Mr. Saleh Alzahrani

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2024 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
SASaleh Alzahrani
Saleh Alzahrani
DKDoğuşhan Kılıç
Doğuşhan Kılıç
MFMichael Flynn
Michael Flynn
PWPaul I. Williams
Paul I. Williams
JAJames Allan
James Allan
Madrid–Barajas Airport (MAD) is the fourth-busiest airport in Europe. The aerosol chemical composition and the concentrations of other key pollutants were measured at the airport perimeter during October 2021 to assess the impact of airport emissions on local air quality. A high-fidelity ambient instrumentation system was deployed at Madrid–Barajas Airport to measure the following: concentrations of organic aerosols (with their composition), black carbon (eBC), carbon dioxide (CO2), carbon monoxide (CO), nitrogen dioxide (NOx), sulfur dioxide (SO2), particulate matter (PM2.5, PM10), total hydrocarbon (THC), and total particle number. The average concentrations of eBC, NOx, SO2, PM2.5, PM10, CO, and THC at the airport for the entire campaign were 1.07 µg m−3, 22.7 µg m−3, 4.10 µg m−3, 9.35 µg m−3, 16.43 µg m−3, 0.23 mg m−3, and 2.30 mg m−3, respectively. The source apportionment analysis of the non-refractory organic aerosol (OA) using positive matrix factorisation (PMF) allowed us to discriminate between different sources of pollution, namely less oxidised oxygenated organic aerosol (LO-OOA), alkane organic aerosol (AlkOA), and more oxidised oxygenated organic aerosol (MO-OOA). The results showed that LO-OOA and MO-OOA account for more than 80 % of the total organic particle mass measured near the runway. Trace gases correlate better with the AlkOA factor than LO-OOA and MO-OOA, indicating that AlkOA is mainly related to primary combustion emissions. Bivariate polar plots were used for pollutant source identification. Significantly higher concentrations of the obtained factors were observed at low wind speeds (<3 m s−1) from the southwest, where two of the runways and all terminals are located. Higher SO2/NOx and CO/eBC ratios were observed when the winds originated from the northeast, where the two northern runways are located. These elevated ratios are attributed to the aircraft activity being the major pollutant source in the northeast area.

6 October 2023 in EGUsphere
Verified
Preprint
Open access
PDF file
SASaleh Alzahrani
Saleh Alzahrani
DKDoğuşhan Kılıç
Doğuşhan Kılıç
MFMichael Flynn
Michael Flynn
PWPaul Williams
Paul Williams
JAJames Allan
James Allan
Madrid-Barajas International Airport (MAD), located in Spanish Capital Madrid, is the fourth-busiest airport in Europe. As part of the AVIATOR campaign, chemical composition of particulate matter and other key pollutants were measured at the airport perimeter during October 2021, to assess the impact of airport emissions on local air quality. A high-fidelity ambient instrumentation system was deployed at Madrid Airport to measure: composition of ambient aerosol and concentrations of black carbon (eBC), carbon dioxide (CO2) carbon monoxide (CO), nitrogen dioxide (NOx), sulphur dioxide (SO2), particulate matter (PM2.5, PM10), total hydrocarbon (THC), and total particle number. The average concentration for the entire campaign of eBC, NOx, SO2, PM2.5, PM10, CO and THC at the airport were, 1.07 (µg/m³), 22.7 (µg/m³), 4.10 (µg/m³), 9.35 (µg/m³), 16.43 (µg/m³), 0.23 (mg/m³) and 2.30 (mg/m³) respectively. The source apportionment analysis of the non-refractory organic aerosol (OA) using positive matrix factorisation (PMF) allowed us to discriminate between different sources of pollution, namely: Semi Volatile Oxygenated Organic Aerosol (SV-OOA), Alkane Organic Aerosol (AlkOA), and More Oxidised Oxygenated Organic Aerosol (MO-OOA) source. The results showed that SVOOA and MO-OOA accounts for more than 80 % of the total organic particle mass that was measured near runway at the airport. Trace gases correlate better with AlkOA factor more than SVOOA and MO-OOA which indicate that AlkOA is mainly related to the primary emissions of combustion. Bivariate polar plots were used for the source identification. Significantly higher concentrations of the obtained factors were observed at low wind speeds < 3m/s from the southwest where two of runways, as well as all terminals are located. Higher SO2/NOx and CO/eBC ratios were observed when the winds originating from the northeast where the 18L/36R runways are located. This is attributed to the aircraft influence and the lack of a local road source in the northeast area.

4 April 2024
Verified
Other
Open access
PDF file
SASaleh Alzahrani
Saleh Alzahrani
DKDoğuşhan Kılıç
Doğuşhan Kılıç
MFMichael Flynn
Michael Flynn
PWPaul Williams
Paul Williams
JAJames Allan
James Allan
Madrid-Barajas International Airport (MAD), located in Spanish Capital Madrid, is the fourth-busiest airport in Europe. As part of the AVIATOR campaign, chemical composition of particulate matter and other key pollutants were measured at the airport perimeter during October 2021, to assess the impact of airport emissions on local air quality. A high-fidelity ambient instrumentation system was deployed at Madrid Airport to measure: composition of ambient aerosol and concentrations of black carbon (eBC), carbon dioxide (CO2) carbon monoxide (CO), nitrogen dioxide (NOx), sulphur dioxide (SO2), particulate matter (PM2.5, PM10), total hydrocarbon (THC), and total particle number. The average concentration for the entire campaign of eBC, NOx, SO2, PM2.5, PM10, CO and THC at the airport were, 1.07 (µg/m³), 22.7 (µg/m³), 4.10 (µg/m³), 9.35 (µg/m³), 16.43 (µg/m³), 0.23 (mg/m³) and 2.30 (mg/m³) respectively. The source apportionment analysis of the non-refractory organic aerosol (OA) using positive matrix factorisation (PMF) allowed us to discriminate between different sources of pollution, namely: Semi Volatile Oxygenated Organic Aerosol (SV-OOA), Alkane Organic Aerosol (AlkOA), and More Oxidised Oxygenated Organic Aerosol (MO-OOA) source. The results showed that SVOOA and MO-OOA accounts for more than 80 % of the total organic particle mass that was measured near runway at the airport. Trace gases correlate better with AlkOA factor more than SVOOA and MO-OOA which indicate that AlkOA is mainly related to the primary emissions of combustion. Bivariate polar plots were used for the source identification. Significantly higher concentrations of the obtained factors were observed at low wind speeds < 3m/s from the southwest where two of runways, as well as all terminals are located. Higher SO2/NOx and CO/eBC ratios were observed when the winds originating from the northeast where the 18L/36R runways are located. This is attributed to the aircraft influence and the lack of a local road source in the northeast area.

4 April 2024
Verified
Other
Open access
PDF file
SASaleh Alzahrani
Saleh Alzahrani
DKDoğuşhan Kılıç
Doğuşhan Kılıç
MFMichael Flynn
Michael Flynn
PWPaul Williams
Paul Williams
JAJames Allan
James Allan
Madrid-Barajas International Airport (MAD), located in Spanish Capital Madrid, is the fourth-busiest airport in Europe. As part of the AVIATOR campaign, chemical composition of particulate matter and other key pollutants were measured at the airport perimeter during October 2021, to assess the impact of airport emissions on local air quality. A high-fidelity ambient instrumentation system was deployed at Madrid Airport to measure: composition of ambient aerosol and concentrations of black carbon (eBC), carbon dioxide (CO2) carbon monoxide (CO), nitrogen dioxide (NOx), sulphur dioxide (SO2), particulate matter (PM2.5, PM10), total hydrocarbon (THC), and total particle number. The average concentration for the entire campaign of eBC, NOx, SO2, PM2.5, PM10, CO and THC at the airport were, 1.07 (µg/m³), 22.7 (µg/m³), 4.10 (µg/m³), 9.35 (µg/m³), 16.43 (µg/m³), 0.23 (mg/m³) and 2.30 (mg/m³) respectively. The source apportionment analysis of the non-refractory organic aerosol (OA) using positive matrix factorisation (PMF) allowed us to discriminate between different sources of pollution, namely: Semi Volatile Oxygenated Organic Aerosol (SV-OOA), Alkane Organic Aerosol (AlkOA), and More Oxidised Oxygenated Organic Aerosol (MO-OOA) source. The results showed that SVOOA and MO-OOA accounts for more than 80 % of the total organic particle mass that was measured near runway at the airport. Trace gases correlate better with AlkOA factor more than SVOOA and MO-OOA which indicate that AlkOA is mainly related to the primary emissions of combustion. Bivariate polar plots were used for the source identification. Significantly higher concentrations of the obtained factors were observed at low wind speeds < 3m/s from the southwest where two of runways, as well as all terminals are located. Higher SO2/NOx and CO/eBC ratios were observed when the winds originating from the northeast where the 18L/36R runways are located. This is attributed to the aircraft influence and the lack of a local road source in the northeast area.


27 October 2023
Verified
Other
Open access
PDF file
SASaleh Alzahrani
Saleh Alzahrani
DKDoğuşhan Kılıç
Doğuşhan Kılıç
MFMichael Flynn
Michael Flynn
PWPaul Williams
Paul Williams
JAJames Allan
James Allan
Madrid-Barajas International Airport (MAD), located in Spanish Capital Madrid, is the fourth-busiest airport in Europe. As part of the AVIATOR campaign, chemical composition of particulate matter and other key pollutants were measured at the airport perimeter during October 2021, to assess the impact of airport emissions on local air quality. A high-fidelity ambient instrumentation system was deployed at Madrid Airport to measure: composition of ambient aerosol and concentrations of black carbon (eBC), carbon dioxide (CO2) carbon monoxide (CO), nitrogen dioxide (NOx), sulphur dioxide (SO2), particulate matter (PM2.5, PM10), total hydrocarbon (THC), and total particle number. The average concentration for the entire campaign of eBC, NOx, SO2, PM2.5, PM10, CO and THC at the airport were, 1.07 (µg/m³), 22.7 (µg/m³), 4.10 (µg/m³), 9.35 (µg/m³), 16.43 (µg/m³), 0.23 (mg/m³) and 2.30 (mg/m³) respectively. The source apportionment analysis of the non-refractory organic aerosol (OA) using positive matrix factorisation (PMF) allowed us to discriminate between different sources of pollution, namely: Semi Volatile Oxygenated Organic Aerosol (SV-OOA), Alkane Organic Aerosol (AlkOA), and More Oxidised Oxygenated Organic Aerosol (MO-OOA) source. The results showed that SVOOA and MO-OOA accounts for more than 80 % of the total organic particle mass that was measured near runway at the airport. Trace gases correlate better with AlkOA factor more than SVOOA and MO-OOA which indicate that AlkOA is mainly related to the primary emissions of combustion. Bivariate polar plots were used for the source identification. Significantly higher concentrations of the obtained factors were observed at low wind speeds < 3m/s from the southwest where two of runways, as well as all terminals are located. Higher SO2/NOx and CO/eBC ratios were observed when the winds originating from the northeast where the 18L/36R runways are located. This is attributed to the aircraft influence and the lack of a local road source in the northeast area.