Dena Goffman

Dr. Dena Goffman


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2020 in New England Journal of Medicine
Verified
Journal Article
Closed access
PDF file
DSDesmond Sutton
Desmond Sutton
KFKarin Fuchs
Karin Fuchs
MDMary D’alton
Mary D’alton
DGDena Goffman
Dena Goffman
In recent weeks, Covid-19 has rapidly spread throughout New York City. The obstetrical population presents a unique challenge during this pandemic, since these patients have multiple interactions with the health care system and eventually most are admitted to the hospital for delivery. We first diagnosed a case of Covid-19 in an obstetrical patient on March 13, 2020, and we previously reported our early experience with Covid-19 in pregnant women, including two initially asymptomatic women in whom symptoms developed and who tested positive for SARS-CoV-2, the virus that causes Covid-19, after delivery.1,2 After these two cases were identified, we implemented universal testing with nasopharyngeal swabs and a quantitative polymerase-chain-reaction test to detect SARS-CoV-2 infection in women who were admitted for delivery.

7 September 2020 in Obstetrics & Gynecology
Verified
Journal Article
Open access
MDMary E. D’aLton
Mary E. D’aLton
KRKara M. Rood
Kara M. Rood
MSMarcela C. Smid
Marcela C. Smid
HSHyagriv N. Simhan
Hyagriv N. Simhan
DSDaniel W. Skupski
Daniel W. Skupski
DGDena Goffman
Dena Goffman
OBJECTIVE: To evaluate the effectiveness and safety of an intrauterine vacuum-induced hemorrhage-control device for postpartum hemorrhage treatment. METHODS: A multicenter, prospective, single-arm treatment study of a novel intrauterine device that uses low-level vacuum to induce uterine myometrial contraction to achieve control of abnormal postpartum uterine bleeding and postpartum hemorrhage was undertaken at 12 centers in the United States. The primary effectiveness endpoint was the proportion of participants in whom use of the intrauterine vacuum-induced hemorrhage-control device controlled abnormal bleeding without requiring escalating interventions. The primary safety endpoint was the incidence, severity, and seriousness of device-related adverse events. Secondary outcomes included time to bleeding control, rate of transfusion, and device usability scored by each investigator using the device. RESULTS: Of 107 participants enrolled with primary postpartum hemorrhage or abnormal postpartum uterine bleeding, 106 received any study treatment with the device connected to vacuum, and successful treatment was observed in 94% (100/106, 95% CI 88–98%) of these participants. In those 100 participants, definitive control of abnormal bleeding was reported in a median of 3 minutes (interquartile range 2.0–5.0) after connection to vacuum. Eight adverse events deemed possibly related to the device or procedure were reported, all of which were outlined as risks in the study and all of which resolved with treatment without serious clinical sequelae. Transfusion of 1–3 units of red blood cells was required in 35 participants, and five participants required 4 or more units of red blood cells. The majority of investigators reported the intrauterine vacuum-induced hemorrhage-control device as easy to use (98%) and would recommend it (97%). CONCLUSION: Intrauterine vacuum-induced hemorrhage control may provide a new rapid and effective treatment option for abnormal postpartum uterine bleeding or postpartum hemorrhage, with the potential to prevent severe maternal morbidity and mortality. FUNDING SOURCE: Alydia Health, Inc. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT02883673.

16 December 2021 in Clinical Obstetrics and Gynecology
Verified
Journal Article
Closed access
EOEve E. Overton
Eve E. Overton
DGDena Goffman
Dena Goffman
AFAlexander M. Friedman
Alexander M. Friedman
As of November, 2021 there have been more than 250 million coronavirus disease-2019 (COVID-19) cases worldwide and more than 5 million deaths. Obstetric patients have been a population of interest given that they may be at risk of more severe infection and adverse pregnancy outcomes. The purpose of this review is to assess current epidemiology and outcomes research related to COVID-19 for the obstetric population. This review covers the epidemiology of COVID-19, symptomatology, transmission, and current knowledge gaps related to outcomes for the obstetric population.

6 August 2021 in Expert Review of Medical Devices
Verified
Journal Article
Open access
MDMary D’alton
Mary D’alton
KRKara Rood
Kara Rood
HSHyagriv Simhan
Hyagriv Simhan
DGDena Goffman
Dena Goffman
Abnormal postpartum uterine bleeding occurs commonly after birth and can quickly become an obstetric emergency. With postpartum hemorrhage representing the leading cause of maternal mortality, acco...

13 September 2023 in Obstetrics & Gynecology
Verified
Journal Article
Open access
DGDena Goffman
Dena Goffman
KRKara M. Rood
Kara M. Rood
ABAngela Bianco
Angela Bianco
JBJoseph R. Biggio
Joseph R. Biggio
PDPaul Dietz
Paul Dietz
HSHyagriv N. Simhan
Hyagriv N. Simhan
OBJECTIVE: To assess the real-world effectiveness and safety of a U.S. Food and Drug Administration (FDA)–cleared intrauterine vacuum-induced-hemorrhage control device for postpartum hemorrhage (PPH) management. METHODS: Sixteen centers in the United States participated in this observational, postmarket registry medical record review (October 2020 through March 2022). The primary effectiveness outcome was treatment success, defined as bleeding control after insertion with no treatment escalation or bleeding recurrence. Additional outcomes included blood loss, time to device insertion, indwelling time, bleeding recurrence, and time to bleeding control. Treatment success and severe maternal morbidity measures (transfusion of 4 or more units of red blood cell, intensive care unit admission, and hysterectomy) were evaluated by blood loss before insertion. To assess safety, serious adverse events (SAEs) and adverse device effects were collected. All outcomes were summarized by mode of delivery; treatment success was summarized by bleeding cause (all causes, any atony, isolated atony, nonatony). RESULTS: In total, 800 individuals (530 vaginal births, 270 cesarean births) were treated with the device; 94.3% had uterine atony (alone or in combination with other causes). Median total blood loss at device insertion was 1,050 mL in vaginal births and 1,600 mL in cesarean births. Across all bleeding causes, the treatment success rate was 92.5% for vaginal births and was 83.7% for cesarean births (95.8% [n=307] and 88.2% [n=220], respectively, in isolated atony). Median indwelling time was 3.1 hours and 4.6 hours, respectively. In vaginal births, 14 SAEs were reported among 13 individuals (2.5%). In cesarean births, 22 SAEs were reported among 21 individuals (7.8%). Three (0.4%) SAEs were deemed possibly related to the device or procedure. No uterine perforations or deaths were reported. CONCLUSION: For both vaginal and cesarean births in real-world settings, rapid and effective bleeding control was achieved with an FDA-cleared intrauterine vacuum-induced hemorrhage-control device. The safety profile was consistent with that observed in the registrational trial (NCT02883673), and SAEs or adverse device effects were of the nature and severity expected in the setting of PPH. This device is an important new tool for managing a life-threatening condition, and timely utilization may help to improve obstetric hemorrhage outcomes. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT04995887.

30 October 2018 in Critical Care
Verified
Journal Article
Open access
PDF file
TGthe CIPHER Group
the CIPHER Group
BPBeth A. Payne
Beth A. Payne
HRHelen Ryan
Helen Ryan
JBJeffrey Bone
Jeffrey Bone
LMLaura A Magee
Laura A Magee
PDPeter von Dadelszen
Peter von Dadelszen
Intensive care unit (ICU) outcome prediction models, such as Acute Physiology And Chronic Health Evaluation (APACHE), were designed in general critical care populations and their use in obstetric populations is contentious. The aim of the CIPHER (Collaborative Integrated Pregnancy High-dependency Estimate of Risk) study was to develop and internally validate a multivariable prognostic model calibrated specifically for pregnant or recently delivered women admitted for critical care. A retrospective observational cohort was created for this study from 13 tertiary facilities across five high-income and six low- or middle-income countries. Women admitted to an ICU for more than 24 h during pregnancy or less than 6 weeks post-partum from 2000 to 2012 were included in the cohort. A composite primary outcome was defined as maternal death or need for organ support for more than 7 days or acute life-saving intervention. Model development involved selection of candidate predictor variables based on prior evidence of effect, availability across study sites, and use of LASSO (Least Absolute Shrinkage and Selection Operator) model building after multiple imputation using chained equations to address missing data for variable selection. The final model was estimated using multivariable logistic regression. Internal validation was completed using bootstrapping to correct for optimism in model performance measures of discrimination and calibration. Overall, 127 out of 769 (16.5%) women experienced an adverse outcome. Predictors included in the final CIPHER model were maternal age, surgery in the preceding 24 h, systolic blood pressure, Glasgow Coma Scale score, serum sodium, serum potassium, activated partial thromboplastin time, arterial blood gas (ABG) pH, serum creatinine, and serum bilirubin. After internal validation, the model maintained excellent discrimination (area under the curve of the receiver operating characteristic (AUROC) 0.82, 95% confidence interval (CI) 0.81 to 0.84) and good calibration (slope of 0.92, 95% CI 0.91 to 0.92 and intercept of −0.11, 95% CI −0.13 to −0.08). The CIPHER model has the potential to be a pragmatic risk prediction tool. CIPHER can identify critically ill pregnant women at highest risk for adverse outcomes, inform counseling of patients about risk, and facilitate bench-marking of outcomes between centers by adjusting for baseline risk.