Isaac Swink

Mr. Isaac Swink


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2020 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
CPChristopher Payne
Christopher Payne
SJStephen Jaffee
Stephen Jaffee
ISIsaac Swink
Isaac Swink
DCDaniel Cook
Daniel Cook
MYMatthew Yeager
Matthew Yeager
BCBoyle C. Cheng
Boyle C. Cheng
Background: A number of minimally invasive sacroiliac (SI) joint fusion solutions for placing implants exist, with reduced post-operative pain and improved outcomes compared to open procedures. The objective of this study was to compare two MIS SI joint fusion approaches that place implants directly across the joint by comparing the ilium and sacrum bone characteristics and SI joint separation along the implant trajectories. Methods: Nine cadaveric specimens (n = 9) were CT scanned and the left and right ilium and sacrum were segmented. The bone density, bone volume fraction, and SI joint gap distance were calculated along lateral and posterolateral trajectories and compared using analysis of variance between the two orientations. Results: Iliac bone density, indicated by the mean Hounsfield Unit, was significantly greater for each lateral trajectory compared to posterolateral. The volume of cortical bone in the ilium was greater for the middle lateral trajectory compared to all others and for the top and bottom lateral trajectories compared to both posterolateral trajectories. Cortical density was greater in the ilium for all lateral trajectories compared to posterolateral. The bone fraction was significantly greater in all lateral trajectories compared to posterolateral in the ilium. No differences in cortical volume, cortical density, or cancellous density were found between trajectories in the sacrum. The ilium was significantly greater in density compared with the sacrum when compared irrespective of trajectory (p < 0.001). The posterolateral trajectories had a significantly larger SI joint gap than the lateral trajectories (p < 0.001). Conclusion: Use of the lateral approach for minimally invasive SI fusion allows the implant to interact with bone across a significantly smaller joint space. This interaction with increased cortical bone volume and density may afford better fixation with a lower risk of pull-out or implant loosening when compared to the posterolateral approach.

16 September 2020 in Global Spine Journal
Verified
Journal Article
Open access
PDF file
JCJake Carbone
Jake Carbone
ISIsaac Swink
Isaac Swink
TMThomas Muzzonigro
Thomas Muzzonigro
DDDaniel Diehl
Daniel Diehl
MOMichael Oh
Michael Oh
BCBoyle C. Cheng
Boyle C. Cheng
Study Design: An in vitro biomechanics study. Objective: To evaluate the efficacy of triangular titanium implants in providing mechanical stabilization to a sacroiliac joint with primary and revision sized implants. Methods: Ten lumbopelvic cadaveric specimens were tested in 4 stages: intact, pubic symphysis sectioned, primary, and simulated revision. Primary treatment was performed using 3 laterally placed triangular titanium implants. To simulate revision conditions before and after bone ingrowth and ongrowth on the implants, 7.5-mm and 10.75-mm implants were randomly assigned to one side of each specimen during the simulated revision stage. A 6 degrees of freedom spinal loading frame was used to load specimens in 4 directions: flexion extension, lateral bending, axial torsion, and axial compression. Biomechanical evaluation was based on measures of sacroiliac joint rotational and translational motion. Results: Both primary and revision implants showed the ability to reduce translational motion to a level significantly lower than the intact condition when loaded in axial compression. Simulated revision conditions showed no statistically significant differences compared with the primary implant condition, with the exception of flexion-extension range of motion where motions associated with the revised condition were significantly lower. Comparison of rotational and translation motions associated with the 7.5- and 10.75-mm implants showed no significant differences between the treatment conditions. Conclusions: These results indicate that implantation of laterally placed triangular titanium implants significantly reduces the motion of a sacroiliac joint using either the primary and revision sized implants. No statistically significant differences were detected when comparing the efficacy of primary, 7.5-mm revision, or 10.75-mm revision implants.

11 July 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
ATAmol H Trivedi
Amol H Trivedi
VWVicki Z. Wang
Vicki Z. Wang
E[Edward McClain IV [suffix]
Edward McClain IV [suffix]
PVPraveer Vyas
Praveer Vyas
ISIsaac Swink
Isaac Swink
PDPatrick J. DeMeo
Patrick J. DeMeo
Musculoskeletal (MSK) pathology encompasses an array of conditions that can cause anything from mild discomfort to permanent injury. Their prevalence and impact on disability have sparked interest in more effective treatments, particularly within orthopedics. As a result, the human placenta has come into focus within regenerative medicine as a perinatal derivative (PnD). These biologics are sourced from components of the placenta, each possessing a unique composition of collagens, proteins, and factors believed to aid in healing and regeneration. This review aims to explore the current literature on PnD biologics and their potential benefits for treating various MSK pathologies. We delve into different types of PnDs and their healing effects on muscles, tendons, bones, cartilage, ligaments, and nerves. Our discussions highlight the crucial role of immune modulation in the healing process for each condition. PnDs have been observed to influence the balance between anti- and pro-inflammatory factors and, in some cases, act as biologic scaffolds for tissue growth. Additionally, we assess the range of PnDs available, while also addressing gaps in our understanding, particularly regarding biologic processing methods. Although certain PnD biologics have varying levels of support in orthopedic literature, further clinical investigations are necessary to fully evaluate their impact on human patients.

6 September 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
BCBoyle C. Cheng
Boyle C. Cheng
ISIsaac Swink
Isaac Swink
CCCooper Thomas Cheng
Cooper Thomas Cheng
OCOwen G. Corcoran
Owen G. Corcoran
VWVicki Z. Wang
Vicki Z. Wang
AYAlexander Yu
Alexander Yu
P-15 is a 15-amino-acid-long biomimetic peptide widely demonstrated to enhance osteogenesis in vivo. Despite the prevalence of polyether-ether-ketone (PEEK) in interbody device manufacturing, a growing body of evidence suggests it may produce an unfavorable immune response. The purpose of this preliminary study was to characterize the immune response and new bone growth surrounding PEEK implants with and without a P-15 peptide-based osteobiologic. A bilateral femoral defect model was conducted using New Zealand white rabbits. A total of 17 test subjects received one implant in each distal femur, either with or without bone graft material. Animals were allowed to survive to 4 or 8 weeks, at which time the femurs were collected and subjected to micro-computer tomography (microCT) or cytokine analysis. MicroCT analysis included the quantification of bone growth and density surrounding each implant. The cytokine analysis of periprosthetic tissue homogenates included the quantification of interleukins (ILs) and TNF-α expression via ELISA kits. Improvements in bone volume were observed in the P-15 cohort for the regions of interest, 500–136 and 136–0 µm from the implant surface, at 8 weeks post-op. Concentrations of IL-1β, IL-4, and IL-6 cytokines were significantly higher in the P-15 cohort compared to the PEEK cohort at the 4-week timepoint. Significant reductions in the concentrations of IL-4 and IL-6 cytokines from the 4- to 8-week cohort were observed in the P-15 cohort only. The P-15 peptide has the potential to modulate the immune response to implanted materials. We observed improvements in bone growth and a more active micro-environment in the P-15 cohort relative to the PEEK control. This may indicate an earlier transition from the inflammatory to remodeling phase of healing.

1 April 2021
Verified
Book Chapter
Closed access
PDF file
ISIsaac Swink
Isaac Swink
SJStephen Jaffee
Stephen Jaffee
DDDaniel Diehl
Daniel Diehl
CXChen Xu
Chen Xu
JCJake Carbone
Jake Carbone
BCBoyle C. Cheng
Boyle C. Cheng

22 October 2020
Verified
Book Chapter
Closed access
PDF file
ISIsaac Swink
Isaac Swink
SJStephen Jaffee
Stephen Jaffee
JCJake Carbone
Jake Carbone
HRHannah Rusinko
Hannah Rusinko
DDDaniel Diehl
Daniel Diehl
TMThomas Muzzonigro
Thomas Muzzonigro