Christopher Lloyd

Dr. Christopher Lloyd


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2024 in Materials
Verified
Journal Article
Open access
PDF file
LZLiena Zaidan
Liena Zaidan
INInna Novodchuk
Inna Novodchuk
AHAlexander H.Xu
Alexander H.Xu
ANAlexandru Nica
Alexandru Nica
Saeed TakalooSaeed Takaloo
Saeed Takaloo
Mustafa YavuzMustafa Yavuz
Mustafa Yavuz
Escherichia coli (E. coli) was among the first organisms to have its complete genome published (Genome Sequence of E. coli 1997 Science). It is used as a model system in microbiology research. E. coli can cause life-threatening illnesses, particularly in children and the elderly. Possible contamination by the bacteria also results in product recalls, which, alongside the potential danger posed to individuals, can have significant financial consequences. We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field-effect transistor (FET) biosensor with B/N co-coped reduced graphene oxide (rGO) gel (BN-rGO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 min. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10–108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-rGO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.

24 June 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
LZLiena Zaidan
Liena Zaidan
INInna Novodchuk
Inna Novodchuk
ANAlexandru Nica
Alexandru Nica
AHAlexander H.Xu
Alexander H.Xu
CLChristopher Lloyd
Christopher Lloyd
Mustafa YavuzMustafa Yavuz
Mustafa Yavuz
We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field effect transistor (FET) biosensor with B/N co-coped graphene oxide (GO) gel (BN-GO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 minutes. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10– 108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-GO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.