Agostino Salvatore Vaiano

Dr. Agostino Salvatore Vaiano

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
AVAgostino Salvatore Vaiano
Agostino Salvatore Vaiano
KHKenneth J. Hoffer
Kenneth J. Hoffer
AGAntonio Greco
Antonio Greco
AGAndrea Greco
Andrea Greco
GDGiovanni D'AMico
Giovanni D'AMico
GSGiacomo Savini
Giacomo Savini
PURPOSE: To evaluate the visual outcomes and possible complications of a new foldable sutureless scleral fixation intraocular lens (SSF-IOL), the Carlevale IOL (Soleko). METHODS: The SSF-IOL, which has two T-shaped self-blocking plugs on each haptic, was inserted into the posterior chamber. Both haptics was grabbed through two sclerotomies and the two short arms were blocked under the scleral flap, without any suture. A complete clinical evaluation was done preoperatively and at 3, 6, and 12 months postoperatively. RESULTS: A total of 54 eyes of 50 consecutive patients were retrospectively analyzed. The mean corrected distance visual acuity was 0.93 ± 0.61 logMAR preoperatively and improved to 0.42 ± 0.34 logMAR at 3 months, 0.42 ± 0.37 logMAR at 6 months, and 0.38 ± 0.38 logMAR at 12 months postoperatively (all P < .0001). The mean corneal endothelial cell density decreased from 1,725.37 ± 528.06 to 1,612.81 ± 522.91 cells/mm 2 at 12 months postoperatively ( P < .0001). The mean IOL tilt value was 3.1 ± 1.1° at 12 months postoperatively. The authors observed 6 cases (11.1%) of intraoperative rupture of the IOL haptics, 4 cases (7.4%) of early hyphema, 4 cases (7.4%) of macular cystoid edema, 2 cases (3.7%) of haptic exposure under the conjunctiva, and 1 (1.8%) late retinal detachment. CONCLUSIONS: This newly introduced surgical technique provided promising results regarding efficacy and safety. Complications occurred in a few cases and were successfully managed. The Carlevale IOL seems to be a surgical solution combining the advantages of an easy and minimally invasive implantation with a good functional recovery with minimal complications. [ J Refract Surg . 2021;37(2):126–132.]

1 February 2003 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
CTCiro Tamburrelli
Ciro Tamburrelli
TSTommaso Salgarello
Tommaso Salgarello
AVAgostino Salvatore Vaiano
Agostino Salvatore Vaiano
LSLuigi Scullica
Luigi Scullica
MPMarino Palombi
Marino Palombi
BBBruno Bagolini
Bruno Bagolini
To determine the reproducibility and accuracy of ultrasonographic (US) measurements of distances between the corneoscleral limbus and the insertion site of the medial (MR) or lateral rectus (LR) muscle compared with intraoperative measurements in patients with strabismus. One eye in each of 17 patients with postoperative secondary strabismus caused by over- or undercorrected eso- and exotropia and one eye of each of 19 patients with previously untreated strabismus underwent five repeated measurements by high-resolution ultrasonography of the distance from the corneoscleral limbus to the muscle insertion and three actual intraoperative measurements. Reproducibility, expressed as the coefficient of variation, accuracy (relative error) of US measurements, and the agreement with intraoperative measurements were assessed. The coefficients of variation for US data were 2.02% and 3.18% for the MR and 7.33% and 11.77% for the LR, in the surgical and untreated groups, respectively. The relative error was 6.15% +/- 8.14% (mean +/- SD) and 3.66% +/- 12.83% for the MR muscle, and 12.21% +/- 10.66% and -7.69% +/- 7.83% for the LR muscle, in the surgical and untreated groups, respectively. The 95% limits of agreement (mean +/- 2 SD) between the US and intraoperative measurements were 0.65 +/- 1.82 and 0.15 +/- 1.42 mm for the MR muscle, and 1.12 +/- 2.01 and -0.49 +/- 0.98 mm for the LR muscle, in the surgical and untreated groups, respectively. The results indicate good reliability and accuracy of US readings and suggest a potential usefulness in preoperative assessment of patients with strabismus with surgical failure and missing preoperative clinical data.

1 September 2005 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
CTCiro Tamburrelli
Ciro Tamburrelli
AGAndrea Giudiceandrea
Andrea Giudiceandrea
AVAgostino Salvatore Vaiano
Agostino Salvatore Vaiano
CCCarmela Grazia Caputo
Carmela Grazia Caputo
FGFrancesca Gulla`
Francesca Gulla`
TSTommaso Salgarello
Tommaso Salgarello
Purpose. To determine whether tonometric readings of increases in intraocular pressure (IOP) during the water-drinking test (WDT) are affected by variations in central corneal thickness (CCT) induced by photorefractive keratectomy (PRK). methods. Data from 30 randomly selected eyes of 30 patients (18 men and 12 women; mean age, ± SD: 33.9 ± 7.6 years) undergoing bilateral PRK for myopia (−6.57 ± 2.39 D) were obtained. Objective refraction, anterior radius of corneal curvature (R), CCT, and IOP measurements at baseline and at different time intervals after ingestion of 1 L of water within 5 minutes, were performed before and 6 months after PRK. All measured IOPs were recalculated by a correction factor for R and CCT and expressed as corrected intraocular pressure (IOPC) measurements. results. The mean R ± SD was 7.84 ± 0.20 and 8.76 ± 0.34 mm, and the mean CCT was 544.83 ± 19.69 and 453.97 ± 29.95 μm, before and after PRK, respectively. The mean IOP at baseline was 15.05 ± 2.78 and 9.83 ± 2.56 mm Hg, and during WDT was 18.32 ± 3.42 and 11.42 ± 3.10 mm Hg at 10 minutes, 18.59 ± 2.99 and 11.54 ± 2.54 mm Hg at 20 minutes, 17.80 ± 2.85 and 10.87 ± 2.22 mm Hg at 30 minutes, 16.35 ± 3.02 and 10.26 ± 2.21 mm Hg at 45 minutes, and 14.90 ± 2.52 and 9.81 ± 2.32 mm Hg at 60 minutes, before and after PRK, respectively. The mean IOPC at baseline was 13.64 ± 2.33 and 13.05 ± 2.98 mm Hg, and during WDT was 16.61 ± 2.77 and 15.08 ± 3.59 mm Hg at 10 minutes, 16.96 ± 2.69 and 15.33 ± 2.96 mm Hg at 20 minutes, 16.10 ± 2.50 and 14.42 ± 2.60 mm Hg at 30 minutes, 14.92 ± 2.72 and 13.62 ± 2.65 mm Hg at 45 minutes, 13.82 ± 2.27 and 13.05 ± 2.55 mm Hg at 60 minutes, before and after excimer laser treatment, respectively. Pre- and postoperative IOPs and percentages of IOP increase differed significantly (P < 0.05), in particular at the peak, as did IOPCs but not the percentages of increase in IOPC, apart from the highest values. conclusions. Corneal changes after PRK for myopia may induce an uneven underestimate of the IOP increases. The inadequacy of a correction factor to compensate for CCT and R at high IOP levels indicates that other biomechanical factors may play a role when the cornea is subjected to dynamic actual IOP variation. Such increase of the well-known underestimate of IOP after PRK at higher actual IOPs may have significant clinical implications in tonometric assessment of subjects at risk of glaucomatous damage.

Verified
Journal Article
Open access
PDF file
PMPaola Marolo
Paola Marolo
Paolo CaselgrandiPaolo Caselgrandi
Paolo Caselgrandi
MGMichele Gaidano
Michele Gaidano
FCFabio Conte
Fabio Conte
GPGuglielmo Parisi
Guglielmo Parisi
MRMichele Reibaldi
Michele Reibaldi
Objectives: This study compared long-term surgical outcomes of the scleral flap versus scleral pocket technique for sutureless intrascleral one-piece intraocular lens (IOL) fixation. Methods: A retrospective comparative study was conducted at a single center, involving consecutive patients undergoing sutureless intrascleral one-piece IOL implantation, between January 2020 and May 2022. Eyes were divided into two groups based on the surgical technique: group 1 underwent scleral flap (n = 64), and group 2 received scleral pocket technique (n = 59). Visual acuity, refractive outcomes, and complications were assessed over a minimum 24-month follow-up period. Results: Both groups showed improvements in best-corrected visual acuity (BCVA), increasing from 0.84 ± 0.56 logMAR at baseline to 0.39 ± 0.23 logMAR (p = 0.042) at 24 months in group 1 and from 0.91 ± 0.63 logMAR at baseline to 0.45 ± 0.38 logMAR (p = 0.039) at 24 months in group 2. No significant differences in BCVA were observed between the groups at baseline (p = 0.991), 12 (p = 0.496) and 24 months (p = 0.557). Mean spherical equivalent (−0.73 ± 1.32 D in group 1 and −0.92 ± 0.99 D in group 2, p = 0.447), refractive prediction error (−0.21 ± 1.1 D in group 1 and −0.35 ± 1.8 D in group 2, p = 0.377), and surgically induced astigmatism (0.74 ± 0.89 D in group 1 and 0.85 ± 0.76 in group 2, p = 0.651) were comparable between the two groups. An IOL tilt of 5.5 ± 1.8 and 5.8 ± 2.0 degrees (p = 0.867) and an IOL decentration of 0.41 ± 0.21 mm and 0.29 ± 0.11 mm (p = 0.955) were obtained, respectively, in group 1 and group 2 at 24 months. Mean endothelial cell density remained stable at 24 months in both groups (p = 0.832 in group 1 and p = 0.443 in group 2), and it was 1747.20 ± 588.03 cells/mm2 in group 1 and 1883.71 ± 621.29 cells/mm2 in group 2 (p = 0.327) at baseline, 1545.36 ± 442.3 cells/mm2 in group 1 and 1417.44 ± 623.40 cells/mm2 in group 2 (p = 0.483) at 24 months. No cases of endophthalmitis were observed. Conclusions: The scleral pocket technique for sutureless intrascleral one-piece IOL fixation is comparable to the traditional scleral flap technique in terms of long-term visual outcomes and safety. The scleral pocket technique offers a simplified approach and a viable option even for less experienced surgeons.

23 September 2025 in Ophthalmology Retina
Verified
Journal Article
Closed access
PMPaola Marolo
Paola Marolo
GPGuglielmo Parisi
Guglielmo Parisi
FCFabio Conte
Fabio Conte
FCFrancesca Cimorosi
Francesca Cimorosi
DTDavide Tibaldi
Davide Tibaldi
MRMichele Reibaldi
Michele Reibaldi

28 March 2023 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
AVAgostino Salvatore Vaiano
Agostino Salvatore Vaiano
AGAntonio Greco
Antonio Greco
AGAndrea Greco
Andrea Greco
MTMaria E Toro
Maria E Toro
MLMarco G Leto
Marco G Leto
GSGiacomo Savini
Giacomo Savini
Purpose: To evaluate a novel surgical combination of ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) and sutureless scleral fixation for Carlevale intraocular lens (SSF-Carlevale IOL) implantation to manage corneal endothelial decompensation when there is a concomitant need for secondary IOL fixation. Methods: Clinical data collected from 10 eyes of 9 patients with bullous keratopathy (BK) who underwent combined UT-DSAEK and SSF-Carlevale IOL implantation in a single procedure were retrospectively analyzed. Anterior chamber IOL (4 cases), aphakia (4 cases, 1 of which associated with PEX), and previous trauma (2 cases) were the conditions responsible for BK. Corrected distance visual acuity (CDVA), intraocular pressure (IOP), endothelial cell density (ECD), central corneal thickness (CCT), graft thickness (GT) and complications were recorded over a 12-month follow-up period. Results: In 90% (9/10) of eyes graft clarity was maintained during follow-up. The mean CDVA improved significantly (p < 0.0001) from 1.78 ± 0.76 logMAR preoperatively to 0.53 ± 0.3 logMAR at 12 months. ECD on average decreased from 2575 ± 125.3 cells/mm2 (donor tissue) to 1697 ± 133.3 cells/mm2 in 12 months. The mean CCT decreased from 870 ± 200 µm to 650 µm ± 9 at 12 months (ANOVA, p = 0.0005). Conclusions: Combined UT-DSAEK and SSF-Carlevale IOL implantation was associated with good corneal graft survival and IOP control, with few complications. These findings suggest that this surgical approach is a practical option for patients requiring both treatment for corneal endothelial dysfunction and secondary IOL implantation.