Dding Tang Tang

Dr. Dding Tang Tang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
DTDding Tang Tang
Dding Tang Tang
SWShuang Wu
Shuang Wu
MKMengqi Kong
Mengqi Kong
ZLZhaonan Liu
Zhaonan Liu
ZLZonghao Li
Zonghao Li
Jie HuJie Hu
Jie Hu
Exercise-induced muscle injury is one of the most common types of sports injuries. Skeletal muscle troponin I (skTnI) serves as an ideal biomarker in assessing such injuries, facilitating timely detection and evaluation. In this study, we develop a fluorescent sandwich lateral flow immunoassay (LFIA) combined with a desktop analyzer for rapid detection of skTnI. Through optimizing the reaction system, the assay achieves a satisfying detection performance, reaching a limit of detection (LOD) of 0.5 ng/mL with a turnaround time of 15 min. The proposed detection platform offers portability, ease of use, and high sensitivity, which facilitates the monitoring of exercise-induced muscle injuries at the point of care. This feature is particularly advantageous for end users, enabling timely detection of sports-related injuries and ultimately enhancing prognosis and sports life.

17 April 2026 in Soft Science
Verified
Journal Article
Open access
PDF file
NCNing Chang
Ning Chang
DWDan Wu
Dan Wu
YSYiming Song
Yiming Song
BJBirui Jin
Birui Jin
LSLijun Su
Lijun Su
HLHao Liu
Hao Liu
Muscle fatigue and injury are the core issues that restrict the improvement of athletes’ competitive performance and the maintenance of sports health for the general population. The traditional muscle health management paradigm is limited by lagging assessment and single indicators, failing to meet the demands of precise training and individualized rehabilitation. With the advances in wearable sensing technology, muscle health management has the potential to transform from the empirical modality to a new data-driven paradigm. However, existing publications either focus on materials innovation and structure design in sensor development, or solely highlight the overlapping physiological mechanisms inducing muscle fatigue and injury. Thus, a comprehensive review presenting insights on the physiological relevance between biological signals fluctuations and muscle health status, the detection mechanisms and functional layouts of wearable sensors to capture these signals, as well as their real-world applications in competitive sports and public fitness is timely needed. Herein, this article systematically reviews the physiological mechanisms of muscle fatigue, injury and repair, with a focus on elaborating the characteristic change patterns of related bioelectrical, biochemical and biomechanical markers in the process. Sensing mechanisms and working layouts of wearable technology are comprehensively summarized. Importantly, corresponding applications in real-world settings associated with improving professional athletic performance and public fitness are proposed, including load monitoring, fatigue evaluation, personalized nutrition management, as well as artificial intelligence (AI)-enabled multimodal fusion. Based on this, future perspectives are envisioned to better aid sports activities and engineer the development of sports science and sports medicine.

26 June 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
DTDding Tang Tang
Dding Tang Tang
SWShuang Wu
Shuang Wu
MKMeng Qi Kong
Meng Qi Kong
ZLZhao Nan Liu
Zhao Nan Liu
NCning chang
ning chang
Jie HuJie Hu
Jie Hu
Exercise-induced muscle injury is one of the most common types of sports injuries. Skeletal muscle troponin I (skTnI) serves as an ideal biomarker in assessing such injuries, facilitating timely detection and evaluation. In this study, we develop a fluorescent sandwich lateral flow immunoassay (LFIA) combined with a desktop analyzer for rapid detection of skTnI. Through optimizing the reaction system, the assay achieves a satisfying detection performance, reaching a limit of detection (LOD) of 0.5 ng/mL with a turnaround time of 15 minutes. The proposed de-tection platform offers portability, ease of use, and high sensitivity, which facilitates the moni-toring of exercise-induced muscle injuries at the point of care. This feature is particularly advan-tageous for end-users, enabling timely detection of sports-related injuries and ultimately en-hancing prognosis and sports life.

31 March 2026 in Journal of Fungi
Verified
Journal Article
Open access
PDF file
YHYing Han
Ying Han
DTDding Tang Tang
Dding Tang Tang
YGYuntong Gao
Yuntong Gao
LJLilian Ji
Lilian Ji
Jie HuJie Hu
Jie Hu
YGYan Gong
Yan Gong
Respiratory fungal infections are challenging to diagnose due to non-specific symptoms and limitations of conventional methods. This study established an integrated, rapid workflow for detecting three common pathogenic fungi, combining an optimized nucleic acid extraction method with a TaqMan-based multiplex real-time qPCR system. The high-salt lysis method yielded high-purity nucleic acid extracts, with performance comparable to or better than commercial kits. The multiplex qPCR assay was optimized for high specificity, sensitivity, and reproducibility, with detection limits as low as 10 CFU/mL for some fungi. Clinical validation using 14 sputum samples demonstrated high agreement with conventional culture, and the assay detected a low-load infection missed by culture. This integrated approach shows great potential for rapid, sensitive, and specific clinical detection of respiratory fungal infections.