An increasing number of medical specialists are using fluoroscopy outside imaging departments, but there has been general neglect of radiological protection coverage of fluoroscopy machines used outside imaging departments. Lack of radiological protection training of those working with fluoroscopy outside imaging departments can increase the radiation risk to workers and patients. Procedures such as endovascular aneurysm repair, renal angioplasty, iliac angioplasty, ureteric stent placement, therapeutic endoscopic retrograde cholangio-pancreatography,and bile duct stenting and drainage have the potential to impart skin doses exceeding Gy. Although tissue reactions among patients and workers from fluoroscopy procedures have, to date, only been reported in interventional radiology and cardiology,the level of fluoroscopy use outside imaging departments creates potential for such injuries.A brief account of the health effects of ionising radiation and protection principles is presented in Section 2. Section 3 deals with general aspects of the protection of workers and patients that are common to all, whereas specific aspects are covered in Section 4 for vascular surgery, urology, orthopaedic surgery, obstetrics and gynaecology,gastroenterology and hepatobiliary system, and anaesthetics and pain management.Although sentinel lymph node biopsy involves the use of radio-isotopic methods rather than fluoroscopy, performance of this procedure in operating theatres is covered in this report as it is unlikely that this topic will be addressed in another ICRP publication in coming years. Information on radiation dose levels to patients and workers, and dose management is presented for each speciality.
15 November 2010 in Catheterization and Cardiovascular Interventions
When this paper was about to go to press, the International Commission on Radiological Protection released a statement recommending a change in the threshold dose for the eye lens and dose limits for eye for occupationally exposed persons. It is clear that the earlier published threshold for radiation cataract is no longer valid. Epidemiological studies among Chernobyl clean-up workers, A bomb survivors, astronauts, residents of contaminated buildings, radiological technicians and recent surveys of staff in interventional rooms indicate that there is an increased incidence of lens opacities at doses below 1 Gy. Nevertheless, eye lens dosimetry is at a primitive stage and needs to be developed further. Despite uncertainties concerning dose threshold and dosimetry, it is possible to significantly reduce the risk of radiation cataract through the use of appropriate eye protection. By increasing awareness among those at risk and better adoption and increased usage of protective measures, radiation cataract can become preventable despite lowering of dose limits.
Background: Recent studies have reported a significant increase in eye lens opacities among staff in the cardiac catheterization laboratory but indicated further studies are needed to confirm the findings. Objective: To evaluate the prevalence of opacities in eyes of cardiologists, radiographers and nurses working in interventional cardiology. Methods: The eyes of 52 staff in interventional cardiology facilities and 34 age- and sex-matched unexposed controls were screened in a cardiology conference held in Kuala Lumpur by dilated slit-lamp examination, and posterior lens changes were graded. Individual cumulative lens X-ray exposures were calculated from responses to a questionnaire in terms of workload and working practice. Results: The prevalence of posterior lens opacities among interventional cardiologists was 53%, while in nurses and radiographers it was 45%. Corresponding relative risks were 2.6 (95% CI: 1.2–5.4) and 2.2 (95% CI: 0.98–4.9), for interventional cardiologists and support staff, respectively. Conclusions: This study confirms a statistically significant increase in radiation-associated posterior lens changes in the eyes of interventional cardiology staff.
1 September 2015 in Journal of Radiological Protection
A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is Hp (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.
OBJECTIVE. The purpose of this study was to survey image quality and the entrance surface air kerma for patients in radiographic examinations and to perform comparisons with diagnostic reference levels.SUBJECTS AND METHODS. In this multinational prospective study, image quality and patient radiation doses were surveyed in 12 countries in Africa, Asia, and Eastern Europe, covering 45 hospitals. The rate of unsatisfactory images and image quality grade were noted, and causes for poor image quality were investigated. The entrance surface doses for adult patients were determined in terms of the entrance surface air kerma on the basis of X-ray tube output measurements and X-ray exposure parameters. Comparison of dose levels with diagnostic reference levels was performed.RESULTS. The fraction of images rated as poor was as high as 53%. The image quality improved up to 16 percentage points in Africa, 13 in Asia, and 22 in Eastern Europe after implementation of a quality control (QC) program. Patient doses varied...