Erica Iammarino

Ms. Erica Iammarino

Università Politecnica delle Marche, Ancona, Marche, Italy
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Erica IammarinoErica Iammarino
Erica Iammarino
Ilaria MarcantoniIlaria Marcantoni
Ilaria Marcantoni
Agnese SbrolliniAgnese Sbrollini
Agnese Sbrollini
Micaela MorettiniMicaela Morettini
Micaela Morettini
Laura BurattiniLaura Burattini
Laura Burattini
Changes in cardiac function and morphology are reflected in variations in the electrocardiogram (ECG) and, in turn, in the cardiac risk indices derived from it. These variations have led to the introduction of normalization as a step to compensate for possible biasing factors responsible for inter- and intra-subject differences, which can affect the accuracy of ECG-derived risk indices in assessing cardiac risk. The aim of this work is to perform a scoping review to provide a comprehensive collection of open-access published research that examines normalized ECG-derived parameters used as markers of cardiac anomalies or instabilities. The literature search was conducted from February to July 2024 in the major global electronic bibliographic repositories. Overall, 39 studies were selected. Results suggest extensive use of normalization on heart rate variability-related indices (49% of included studies), QT-related indices (18% of included studies), and T-wave alternans (5% of included studies), underscoring their recognized importance and suggesting that normalization may enhance their role as clinically useful risk markers. However, the primary objective of the included studies was not to evaluate the effect of normalization itself; thus, further research is needed to definitively assess the impact and advantages of normalization across various ECG-derived parameters.

11 April 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Ilaria MarcantoniIlaria Marcantoni
Ilaria Marcantoni
Erica IammarinoErica Iammarino
Erica Iammarino
ADAlessandro Dell'Orletta
Alessandro Dell'Orletta
Laura BurattiniLaura Burattini
Laura Burattini
Background/Objectives: Noninvasive arrhythmic risk stratification in patients with ischemic heart disease is poor nowadays, and further investigations are needed. The most correct approach is based on the use of electrocardiogram (ECG) with the extraction of indices such as ECG alternans (ECGA). The aim of this study is to monitor the ECG evidence of ischemic coronary artery occlusion by the ECGA and to verify its ability to monitor the time course of balloon inflation, with the final goal of contributing to the exploration of the prognostic role of ECGA in ischemic heart disease. Methods: The ECGA amplitude and magnitude were computed by the correlation method (CM) on the STAFF III database, where ischemic coronary artery occlusion was induced in a controlled manner through coronary artery blockage by balloon inflation. ECGA computed during balloon inflation was also compared with periods before and after the inflation. Results: ECGA values became statistically higher during inflation than in the pre-inflation period and increased as inflation time increased, although not always in a statistically significant manner. ECGA went from values in the range 4–7 µV and 169–396 µV·beat before inflation to values in the range 5–9 µV and 208–573 µV·beat during 5 min of inflation (resulting statistically higher than before inflation), returning towards values in the range 4–8 µV and 182–360 µV·beat after inflation for amplitude and magnitude, respectively. Conclusions: CM-based ECGA detection was able to track the balloon inflation period. Our ECGA investigation represents a contribution in the field of research exploring its prognostic role as a noninvasive electrical risk index in ischemic heart disease.

12 February 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Erica IammarinoErica Iammarino
Erica Iammarino
Ilaria MarcantoniIlaria Marcantoni
Ilaria Marcantoni
SGSebastiano Grillo
Sebastiano Grillo
Laura BurattiniLaura Burattini
Laura Burattini
Electroencephalography (EEG) is an effective tool for monitoring the psycho-emotional state induced by open-skill sport activities characterized by dynamic environments and unpredictable situations, offering objective insights into mental engagement. This study aims to characterize the psycho-emotional state induced by table tennis sport activity by exploiting EEG-derived biomarkers. The ‘Real World Table Tennis’ database was analyzed, which includes EEG signals of 25 subjects acquired before, during and after playing table tennis. After preprocessing, 30-s EEG epochs were recursively extracted every 5 s. For each epoch, EEG rhythms were extracted and combined to obtain 37 engagement indexes, defined as ratios of two or more EEG rhythm powers. Median trends of each index were obtained for five cortical regions, and the Wilcoxon signed-rank test was applied to assess significant temporal changes. Results show that engagement indexes can effectively characterize psycho-emotional dynamics during table tennis, capturing the transition from resting to game phase in all cortical regions and exhibiting an increasing trend when having beta/alpha in their definition, and a decreasing trend when having high-frequency rhythms in the denominator. Our findings demonstrate the feasibility of using engagement indexes to monitor psycho-emotional states induced by open-skill sports and provide a framework for investigating mental engagement over time.

15 July 2025 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
Ilaria MarcantoniIlaria Marcantoni
Ilaria Marcantoni
Erica IammarinoErica Iammarino
Erica Iammarino
Agnese SbrolliniAgnese Sbrollini
Agnese Sbrollini
Micaela MorettiniMicaela Morettini
Micaela Morettini
Cees A. SwenneCees A. Swenne
Cees A. Swenne
Laura BurattiniLaura Burattini
Laura Burattini

10 July 2025 in IEEE Open Journal of Engineering in Medicine and Biology
Verified
Journal Article
Open access
MHD JAFAR MORTADAMHD JAFAR MORTADA
MHD JAFAR MORTADA
Agnese SbrolliniAgnese Sbrollini
Agnese Sbrollini
IMIlaria Marcantoni
Ilaria Marcantoni
Erica IammarinoErica Iammarino
Erica Iammarino
Laura BurattiniLaura Burattini
Laura Burattini
PDPeter Van Dam
Peter Van Dam
CineECG, a vectorcardiography-based method, uses standard 12-lead electrocardiography and 3D heart and torso models to depict the electrical activation path during the heart cycle, offering detailed visualization of cardiac electrical activity without numerical quantification. Our research aims to quantify CineECG outputs by defining 54 features that describe the route, shape, and direction of electrical activation. These features were used to develop a multinomial regression model classifying electrocardiography signals into normal sinus rhythm, left bundle branch block, right bundle branch block, and undetermined abnormalities. Trained and tested on 6,860 signals from the PhysioNet/Computing in Cardiology Challenge 2020 and THEW project, the model achieved an F1 score over 84% (normal sinus rhythm: 93%, left bundle branch block: 93%, right bundle branch block: 90%, undetermined abnormalities: 84%). The results suggest CineECG's potential in enhancing electrocardiography interpretation and aiding in the accurate diagnosis of various abnormalities.

18 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Erica IammarinoErica Iammarino
Erica Iammarino
Ilaria MarcantoniIlaria Marcantoni
Ilaria Marcantoni
Agnese SbrolliniAgnese Sbrollini
Agnese Sbrollini
MHD JAFAR MORTADAMHD JAFAR MORTADA
MHD JAFAR MORTADA
Micaela MorettiniMicaela Morettini
Micaela Morettini
Laura BurattiniLaura Burattini
Laura Burattini
Electroencephalography (EEG) wearable devices are particularly suitable for monitoring a subject’s engagement while performing daily cognitive tasks. EEG information provided by wearable devices varies with the location of the electrodes, the suitable location of which can be obtained using standard multi-channel EEG recorders. Cognitive engagement can be assessed during working memory (WM) tasks, testing the mental ability to process information over a short period of time. WM could be impaired in patients with epilepsy. This study aims to evaluate the cognitive engagement of nine patients with epilepsy, coming from a public dataset by Boran et al., during a verbal WM task and to identify the most suitable location of the electrodes for this purpose. Cognitive engagement was evaluated by computing 37 engagement indexes based on the ratio of two or more EEG rhythms assessed by their spectral power. Results show that involvement index trends follow changes in cognitive engagement elicited by the WM task, and, overall, most changes appear most pronounced in the frontal regions, as observed in healthy subjects. Therefore, involvement indexes can reflect cognitive status changes, and frontal regions seem to be the ones to focus on when designing a wearable mental involvement monitoring EEG system, both in physiological and epileptic conditions.