Seyma Teberik

Mrs. Seyma Teberik

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2023 in Konya Journal of Engineering Sciences
Verified
Journal Article
Open access
PDF file
YKYunus Emre Kebeli
Yunus Emre Kebeli
STSeyma Teberik
Seyma Teberik
EAErsin AYDIN
Ersin AYDIN
FCFatih Celik
Fatih Celik
One of the biggest problems encountered in many experimental studies is examining a real-size structure in the field or in a laboratory environment. With today's technological opportunities, it is possible to experimentally examine a real-sized structure in the field or in a laboratory environment. However, to do this, the manufacture of a large, real-size structure, experimental setup and measuring devices are required, which are costly. For this reason, it is not always possible to reach such a laboratory environment. It is very difficult to experimentally examine large-scale structures both economically and in terms of time saving. In this context, in this study, a scaling factor (λ) widely accepted in the literature was used to design a scaled model to represent a real-size structure. λ=10 was used in this scaling approach. A real-size three-story single-span steel prototype building was scaled to a laboratory-scale model structure and analyzed digitally with the Sap2000 program. The natural period/frequency values of the real-size prototype structure and the scaled model modeled in the Sap2000 program were examined. Later, Time history analyzes were performed using real earthquake records from El Centro (1940), Kobe (1995) and Northridge (1994). While real earthquake records were used as they were in the analysis of the prototype structure, these real earthquake records were used by scaling them depending on the scaling factor λ in the analysis of the scaled model. Subsequently, the digital analyzes of the prototype and scaled structure were compared by looking at the acceleration and displacement values of each floor. It was observed that the results were close to each other when scaled according to the scaling factor (λ). This situation demonstrated the accuracy of the scaling rates applied within the scope of the study. Thus, it has been shown that a real-size structure can be scaled to a model in a laboratory environment with correct scaling methods and that this prototype structure can be analyzed with more economical and simple methods.

26 February 2025 in Buildings
Verified
Journal Article
Open access
PDF file
STSeyma Teberik
Seyma Teberik
FCFatih Celik
Fatih Celik
EAErsin AYDIN
Ersin AYDIN
Structural damages occurred during any earthquake arise not only from structural design flaw but also from the variability of sub-base soil behavior and the foundation system. For this reason, structure–soil–pile interaction has an important place in evaluating the behavior of a structure under dynamic effects. Bored pile application, which is one of the deep foundation systems, is a widely used method in the world to transfer the loads coming from the structure to the ground safely in problematic grounds. For this reason, in pile foundation system designs, how bored pile foundation systems will affect the structural design under earthquake loads is considered an important issue. In particular, how diagonally braced steel structures with piled raft foundation systems will behave under earthquake effects has been evaluated as a subject that needs to be examined. For this reason, this situation was evaluated as the main purpose of this study. The effect of the bored pile systems designed in different orientations on the behavior of diagonally braced steel structures during an earthquake under kinematic and inertial effects was investigated in detail within the scope of this study. Numerical analyses, based on data from shake table experiments on a scaled superstructure, examine various pile design scenarios. Experimental base shear force measurements informed the development of numerical scenarios, which varied pile lengths and inter-pile distances while maintaining constant pile diameters. This study analyzed the kinematic and inertial effects on the piles, offering insights into their structural behavior under seismic conditions. The increase in pile length and the increase in the distance between the piles caused a significant increase in the bending moment and shear force, which have an important place in pile design.