With increasing mean and extreme temperatures due to climate change, it becomes necessary to use—not only future typical conditions—but future heatwaves in building thermal simulations as well. Future typical weather files are widespread, but few researchers have put together methodologies to reproduce future extreme conditions. Furthermore, climate uncertainties need to be considered and it is often difficult due to the lack of data accessibility. In this article, we propose a methodology to re-assemble future weather files—ready-to-use for building simulations—using data from the European Coordinated Regional Downscaling Experiment (EURO-CORDEX) dynamically downscaled regional climate multi-year projections. It is the first time that this database is used to assemble weather files for building simulations because of its recent availability. Two types of future weather files are produced: typical weather years (TWY) and heatwave events (HWE). Combined together, they can be used to fully assess building resilience to overheating in future climate conditions. A case study building in Paris is modelled to compare the impact of the different weather files on the indoor operative temperature of the building. The results confirm that it is better to use multiple types of future weather files, climate models, and or scenarios to fully grasp climate projection uncertainties.
1 May 2013 in Advances in Building Energy Research
Thermal energy storage in buildings is essential to reduce energy consumption, to switch electrical consumption from on-peak period to off-peak period and to develop the use of intermittent renewable energy sources. Several systems designed to store thermal energy on a short-term scale (maximum a few days of storage) are presented in previous publications. However, there are no available comparisons of these systems and their conditions of use. This paper details these different designs for short-term scale thermal energy storage, regarding (i) their passive or active nature, (ii) their usage conditions and (iii) their performances. In the first section, the thermal properties of materials are listed. In particular, advantages and problems associated with phase change materials are presented. Subsequently, thermal storage systems are presented in two parts, on the one hand, passive systems and on the other hand active systems, according to the fluid used. For each system, the advantages of substituting sensible storage with latent storage are highlighted. Furthermore, an original and comparative analysis of published studies attempts to define some criteria and requirements for efficient use of latent storage. This review demonstrates that an exhaustive comparison of the systems encounters difficulties, due to the differences between the studies with respect to experimental measurements and weather data and the lack of similar comparison criteria, such as decrement factor, efficiency and cost.
Following development and validation of the SOLENE-microclimat tool, the underlying model was used to compare the impacts of various “greening strategies” on buildings’ summer energy consumption and indoor comfort. This study distinguishes between direct and indirect impacts by successively implementing the test strategies on both the studied building and surrounding ones; it also considers insulated vs. non-insulated buildings. Findings indicate that green walls have a direct effect on indoor comfort throughout the entire building, whereas the effect of green roofs is apparently primarily confined to the upper floor. Moreover, the indirect effect of a green wall is greater, mainly due to the drop in infrared emissions resulting from a lower surface temperature. It has also been proven that the indirect effects of green walls and surrounding lawns can help reduce the loads acting on a non-insulated building.
This paper presents a new air-heating system concept for energy-efficient dwellings. It is a system designed to heat a low-energy building by coupling a heat-recovery ventilation system with a three-fluid heat exchanger located on the chimney of a wood-pellet stove. The proposed work focuses on the heat transfer that occurs between flue gases, the ventilation air and the combustion air within a triple concentric tube heat exchanger with no insulation at its outer surface. The main objective is to predict outlet temperature for the specific geometry of the heat exchanger studied here. Thus, the governing differential equations are derived for a counter-co-current flow arrangement of the three fluids. Then analytical solutions for the steady-state temperature distribution are obtained as well as the amount of heat transferred to the outside. An expression for the effectiveness of the heat exchanger is also proposed. Based on these results, calculations are performed on a case study to predict the fluid temperature distribution along the heat exchanger. Finally, a parametric study is carried out on this case study to assess the influence of the relevant parameters on the effectiveness of the heat exchanger. In addition, computation of heat losses to the outside justifies whether insulation is needed.
In this paper, experimental tests conducted on a new wood-based air-heating system for energy-efficient dwellings are presented. The main objective is to evaluate the resulting outlet temperatures and the amount of heat recovered by the ventilation air in order to assess feasibility and performance of coupling a mechanical ventilation heat-recovery unit and a triple concentric tube heat exchanger integrated into the chimney of a room-sealed wood-pellet stove to heat an entire house. After introducing the context of this work, the three main components of the combined system developed here, the coupling configuration adopted, as well as the protocol used and the sensors implemented on an experimental setup carried out in a laboratory are detailed in turn. Then, the heat transfer rates obtained from measurements for the various fluids as well as the effectiveness of the heat exchangers are presented and discussed. Finally, the resulting outlet temperatures of the three fluids exchanging in the triple concentric tube heat exchanger studied here are compared to those provided by analytical solutions obtained with a mathematical model. It is shown that heat transfer rates are predicted with a relative difference that is lower than 5% compared to experimental values and that such a system enables to cover all or most of heat losses in an energy efficient building.