Gerard Fernando

Prof. Gerard Fernando

Sensors and Composites Group, School of Metallurgy and Materials, University of Birmingham, Edgbaston, Birmingham B15 2TT, UK
orcid

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 1990 in Composites
Verified
Journal Article
Closed access
BHB. Harris
B. Harris
HRH. Reiter
H. Reiter
TAT. Adam
T. Adam
RDR.F. Dickson
R.F. Dickson
GFGerard Fernando
Gerard Fernando

1 July 1989 in International Journal of Fatigue
Verified
Journal Article
Closed access
TAT Adam
T Adam
GFGerard Fernando
Gerard Fernando
RDR Dickson
R Dickson
HRH Reiter
H Reiter
BHB Harris
B Harris

1 April 1998 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
CDC Doyle
C Doyle
AMA Martin
A Martin
TLT Liu
T Liu
MWM Wu
M Wu
SHS Hayes
S Hayes
GFGerard Fernando
Gerard Fernando

19 April 2007 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
VMV.R. Machavaram
V.R. Machavaram
RBRodney Badcock
Rodney Badcock
GFGerard Fernando
Gerard Fernando

1 September 2012 in Thermochimica Acta
Verified
Journal Article
Open access
SPSurya D. Pandita
Surya D. Pandita
LWLiwei Wang
Liwei Wang
RMRamani S. Mahendran
Ramani S. Mahendran
VMVenkata R. Machavaram
Venkata R. Machavaram
MIMuhammad S. Irfan
Muhammad S. Irfan
GFGerard Fernando
Gerard Fernando
The top-cover of a conventional differential scanning calorimeter (DSC) was modified to accommodate two custom-made fibre-optic probes. The function of the probes was to illuminate the sample and reference compartments of the DSC and to return the reflected light from the DSC pans to a fibre-coupled Fourier transform near-infrared (FTIR) spectrometer. The cross-linking kinetics of a commercially available epoxy/amine resin system were studied using the conventional and modified DSC along with conventional transmission FTIR spectroscopy. The cross-linking kinetics and the activation energies for the epoxy/amine resin system obtained via the conventional DSC and simultaneous DSC/FTIR were similar (60.22–60.97 kJ mol−1). However, the activation energy obtained for the cuvette-based conventional transmission FTIR experiments was found to be lower (54.66 kJ mol−1). This may be attributed to the temperature-control attained within the cuvette holder. The feasibility of using a simple fibre-optic probe to link the DSC to the FTIR spectrometer was demonstrated

1 March 2000 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
TLT. Liu
T. Liu
GFGerard Fernando
Gerard Fernando
We report a novel frequency multiplexing method for addressing low finesse fiber Fabry–Perot sensors using a white light source and a CCD based monochromator. The absolute optical path length imbalance of the sensors can be determined using this method. The concept was demonstrated with three fiber Fabry–Perot interferometers for strain and displacement measurements. The accuracy is better than 0.01 μm and the maximum range is approximately 1 mm.