Yi Liu

Yi Liu


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ding DangDing Dang
Ding Dang
YLYi Liu
Yi Liu
Seon Keun LeeSeon Keun Lee
Seon Keun Lee
This paper explores the combination of a data mining-based state evaluation method for electrical equipment in substations, analyzing the effectiveness and accuracy. First, a Gaussian mixture model is applied to fit all raw data of electrical equipment. The Expectation Maximization algorithm summarizes the data distribution characteristics and identifies outliers. The a priori algorithm is then employed for data mining to derive frequent itemsets and association rules between equipment quality and measurement data. For new equipment samples, conditional probabilities of each feature are independently calculated and combined to classify and evaluate equipment quality. The results suggest that equipment reliability in smart substations can be inferred from historical and real-time operational data using improved association rule algorithms and Naive Bayes classifiers. Finally, the proposed method was applied to analyze statistical data from a 110 kV substation of a power supply company. The states prediction accuracy exceeded 95% when compared with actual equipment quality. The effectiveness evaluation metrics demonstrated that this method outperforms single-category algorithms in terms of accuracy and discrimination ability.

13 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
YLYi Liu
Yi Liu
Ding DangDing Dang
Ding Dang
Seon Keun LeeSeon Keun Lee
Seon Keun Lee
A smart grid protection system based on phasor information at circuit breakers is proposed in this paper. Phasor data for fault diagnosis is obtained from phasor measurement units or intelligent electronic devices installed near circuit breakers, without the need for additional measurement equipment. When a fault occurs, the protection system first locates the core protection circuit breaker closest to the fault point. It then identifies the faulty component by analyzing the current phasor differences between this breaker and adjacent ones. This scheme offers high computational efficiency, enabling rapid identification of faulty equipment and its precise location. The proposed protection system structure can be divided into two types: centralized and decentralized, and the most suitable scheme should be selected based on the actual situation. Finally, the feasibility of the proposed scheme was verified through the IEEE 39-bus system and a simulated actual area power grid model, demonstrating its applicability to practical smart grid scenarios. The simulation network validates the implementation method of the proposed protection strategy.