Maris OZOLINSH

Prof. Maris OZOLINSH

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2024 in Vision
Verified
Journal Article
Open access
PDF file
NRNicola Rizzieri
Nicola Rizzieri
LDLuca Dall'Asta
Luca Dall'Asta
MOMaris OZOLINSH
Maris OZOLINSH
Computer vision is a powerful tool in medical image analysis, supporting the early detection and classification of eye diseases. Diabetic retinopathy (DR), a severe eye disease secondary to diabetes, accompanies several early signs of eye-threatening conditions, such as microaneurysms (MAs), hemorrhages (HEMOs), and exudates (EXs), which have been widely studied and targeted as objects to be detected by computer vision models. In this work, we tested the performances of the state-of-the-art YOLOv8 and YOLOv9 architectures on DR fundus features segmentation without coding experience or a programming background. We took one hundred DR images from the public MESSIDOR database, manually labelled and prepared them for pixel segmentation, and tested the detection abilities of different model variants. We increased the diversity of the training sample by data augmentation, including tiling, flipping, and rotating the fundus images. The proposed approaches reached an acceptable mean average precision (mAP) in detecting DR lesions such as MA, HEMO, and EX, as well as a hallmark of the posterior pole of the eye, such as the optic disc. We compared our results with related works in the literature involving different neural networks. Our results are promising, but far from being ready for implementation into clinical practice. Accurate lesion detection is mandatory to ensure early and correct diagnoses. Future works will investigate lesion detection further, especially MA segmentation, with improved extraction techniques, image pre-processing, and standardized datasets.

15 February 2023 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
ZJZane Jansone-Langina
Zane Jansone-Langina
MOMaris OZOLINSH
Maris OZOLINSH
Questionnaires have been used as research tools to provide a standardized approach to assess quality of life at various time periods and populations. However, literature shows only a few articles about self-reported color vision changes. Our aim was to evaluate the subjective patient feelings before and after cataract surgery and compare the results with a color vision test result. Our method was as follows: 80 cataract patients filled out a modified color vision questionnaire and performed the Farnsworth-Munsell 100 Hue Color Vision Test (FM100) before, two weeks, and six months after cataract surgery. We analyzed the correlations between these two types of results, which reveal that FM100 hue performance and subjective perception improved after surgery. Additionally, subjective patient questionnaire scores correlate well with the FM100 test results before and two weeks after the cataract surgery, but this effect decreased with longer follow-up times. We conclude that subjective color vision changes can only be noticed at longer periods after the cataract surgery. Health care professionals can use this questionnaire to better understand the subjective feelings of patients and monitor their color vision sensitivity changes. (c) 2023 Optica Publishing Group

20 December 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NRNicola Rizzieri
Nicola Rizzieri
LDLuca Dall'Asta
Luca Dall'Asta
MOMaris OZOLINSH
Maris OZOLINSH
Myopia is an eye disorder of global concern due to its increasing prevalence worldwide and its potential to cause sight-threatening conditions. Diagnosis is based on clinical tests such as objective cycloplegic refraction, distance visual acuity, and axial length measurements. Population-based screening is an early detection method that helps prevent uncorrected vision disorders. Advancements in technology and artificial intelligence (AI) applications in the medical field are improving the speed and efficiency of patient care programs. In an effort to provide a new, objective AI-based method for early myopia detection, we developed an algorithm based on the YOLOv8 convolutional neural network, capable of classifying eye fundus images from myopic and non-myopic patients. Preliminary results from an image set obtained from an Italian optometric practice show an overall accuracy of 85.00% and a precision and recall of 88.7% and 91.7%, respectively, in the internal validation dataset. This represents the beginning of a new paradigm, where AI is central to large screening programs aimed at preventing myopia and other avoidable blinding conditions and enabling early diagnosis and management.

23 September 2025 in Life
Verified
Journal Article
Open access
PDF file
NRNicola Rizzieri
Nicola Rizzieri
LDLuca Dall'Asta
Luca Dall'Asta
MOMaris OZOLINSH
Maris OZOLINSH
Myopia is a common refractive error with a rising prevalence worldwide, and its early diagnosis is crucial to prevent long-term visual impairment. This study presents an accessible, automated approach for detecting myopia from fundus photographs by analyzing the optic disc, using a deep learning model based on the YOLO (You Only Look Once) architecture, version 8 and 11. The pipeline was designed to be usable by eye care practitioners (ECPs) with no expertise in computer science. Fundus images were processed to extract the optic disc region using a custom-trained YOLOv8 model, and a subsequent classification algorithm determined the presence or absence of myopia based on features from the extracted region. The system was trained on a single-clinic dataset of 730 augmented images, with 98 images reserved for internal validation, and tested on 50 independent optic disc images. It achieved a high diagnostic accuracy, with strong sensitivity and F1 scores. Lightweight models such as YOLOv11-nano performed comparably to larger variants in the testing dataset (AUC 97.5% vs. 97.3%), effectively supporting myopia detection. This work highlights the feasibility of integrating AI-based screening tools into clinical practice without requiring advanced technical skills, offering a scalable and cost-effective solution to support early diagnosis of myopia in diverse healthcare settings.

13 December 2013 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
KLK Luse
K Luse
MOMaris OZOLINSH
Maris OZOLINSH
SFS Fomins
S Fomins
AGA Gutmane
A Gutmane
The aim of the study is to determine the consistency of the desired colour reproduction of the stimuli using calibrated printing technology available to anyone (EpsonStylus Pro 7800 printer was). 24 colour vision assessment plates created in the University of Latvia were analysed right after their fabrication on august 2012 and after intense use for 7 months (colour vision screening on 700 people). Multispectral imagery results indicate that the alignment of the samples after seven months of use has maintained on the CIExy confusion lines of deutan deficiency type, but the shift towards achromatic area in the diagram indicate decrease in the total colour difference (ΔE*ab) of test background (achromatic) areas and stimuli (chromatic) areas, thus affecting the testing outcome and deficiency severity level classification ability of the plates.

20 November 2024 in Optics
Verified
Journal Article
Open access
PDF file
VKVaris Karitans
Varis Karitans
MOMaris OZOLINSH
Maris OZOLINSH
SFSergejs Fomins
Sergejs Fomins
In the current study, we address the phase retrieval of one-dimensional phase objects from near-field diffraction patterns using the multiple-plane Gerchberg–Saxton algorithm, which is still widely used for phase retrieval. The algorithm was implemented in a low-cost digital signal processor capable of fast Fourier transform using Q15 arithmetic, which is used by the previously mentioned algorithm. We demonstrate similarity between one-dimensional phase objects, i.e., vectors cut out of a phase map of the tertiary spherical aberration retrieved by the multiple-plane Gerchberg–Saxton algorithm, and these vectors are measured with a non-contact profiler. The tertiary spherical aberration was induced by a phase plate fabricated using grayscale lithography. After subtracting the vectors retrieved by the algorithm from those measured with the profiler, the root mean square error decreased, while a corresponding increase in the Strehl ratio was observed. A single vector of size 64 pixels was retrieved in about 2 min. The results suggest that digital signal processors that are capable of one-dimensional FFT and fixed-point arithmetic in Q15 format can successfully retrieve the phase of one-dimensional objects, and they can be used for applications that do not require real-time operation, i.e., analyzing the quality of cylindrical micro-optics.