Capillary electrophoresis (CE) is an effective tool for the analysis of many biocomponents, such as dsDNA, RNA, amino acids and bacteria, which are extremely important not only in research work but also in numerous practical applications. However, there are many factors that affect the separation performance, including the polymers inside the capillary, the electric field strength, the capillary coating and the effective length of the capillary. So far, various CE techniques have been developed to increase the resolution, sample volume consumption and limit of detection. To better understand the development of techniques for the separation of these biomolecules by CE, this review provides a comprehensive summary of polymers (e.g., polyvinylpyrrolidone, hydroxyethyl cellulose and polyethylene glycol), optimization methods, capillary coating methods, technological advancement of microchips for CE and the limitation of detection proposed by different groups worldwide. We also discuss the challenges and future directions associated with CE technology.
Metabolic reprogramming, a pivotal hallmark of cancer, plays a crucial role in both the initiation and progression of colorectal cancer (CRC). Despite the vast unknowns surrounding the identity and biological activities of most natural metabolites in diseases, our study, utilizing native metabolomics results through GC–MS/MS, identified a small molecule, 4,4-Dimethyl-2-cyclohexen-1-one, named HEX-1 in the serum of CRC patients. We have further explored and assessed its biological activities. HEX-1 suppressed the proliferation of cancer cells and tumorigenesis via the inactivation and sensitization of PIN1. Notably, HEX-1 exhibits similar functional effects as all-trans retinoic acid (atRA) but stands out by not inducing the degradation of PIN1 mRNA or protein expression, unlike biological compounds associated with atRA. HEX-1 demonstrated the ability to induce G1/S arrest in vitro and ameliorate the progression of inflammatory CRC in mice by remodeling the gut microbiota. As volatile organic compounds (VOCs), HEX-1 could be detected feasibly. Its unique ability to penetrate whole cell populations positions it as a promising approach for cancer therapy and as an enhancer for chemotherapy and immunotherapy. The findings suggest that HEX-1 holds the potential as a valuable addition to the armamentarium against CRC. Graphical Abstract
Capillary electrophoresis (CE) is widely used for DNA fragment analysis, but its separation performance depends strongly on the composition of the polymer sieving matrix, especially in multicapillary systems where matrix operability and reproducibility are critical. Herein, a laboratory-built multicapillary electrophoresis system was used to optimize the sieving matrix for high-throughput DNA fragment separation. The system integrated twelve fused-silica capillaries, high-voltage electrokinetic injection, fluorescence detection, and digital electropherogram acquisition. Using a 100 bp DNA ladder as the model sample, the effects of poly(ethylene oxide) (PEO), Tween 20, and glycerol on electropherogram quality were systematically investigated. PEO concentration was the dominant factor controlling the dynamic sieving network: 0.1% PEO provided insufficient separation, whereas 0.8–1.0% PEO produced clearly resolved DNA peaks. Tween 20 improved peak regularity and electropherogram quality under the tested conditions, with 0.05% providing sufficient improvement without prolonging migration time. Glycerol affected peak distribution by increasing apparent migration resistance in the polymer matrix; however, excessive glycerol slowed DNA migration and markedly extended the separation window. Considering separation quality, matrix operability, and analytical efficiency, 1.0% PEO, 0.05% Tween 20, 2.5% glycerol, 1× SYBR Gold, and 0.5× TBE were selected as the optimized sieving matrix. Under the optimized matrix, inter-capillary migration-time alignment improved the consistency of parallel capillary outputs, with corrected migration-time RSD values generally below 0.5%. The optimized formulation provides a practical basis for high-throughput CE-based DNA fragment analysis.