Nima Tabatabaei

Prof. Nima Tabatabaei


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2009 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
NTNima Tabatabaei
Nima Tabatabaei
AMAndreas Mandelis
Andreas Mandelis
Combining the ideas behind linear frequency modulated continuous wave radars and frequency domain photothermal radiometry (PTR), a novel PTR method is introduced. Analytical solutions to the heat diffusion problem for both opaque and transparent solids are provided. Simulations and experimental results suggest a significant improvement in the dynamic range when using the thermal-wave radar (TWR) instead of conventional PTR. A practical TWR image resolution augmentation method is proposed.

18 April 2011 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
NTNima Tabatabaei
Nima Tabatabaei
AMAndreas Mandelis
Andreas Mandelis
BABennett T. Amaechi
Bennett T. Amaechi
One major problem of frequency-domain photothermal radiometry, or alternatively in two-dimensional lock-in thermography, is the compromise one has to make between dynamic range (probing depth) and depth resolution. The thermal-wave radar incorporates chirped excitation through matched filtering to maintain good resolution and depth range inside a sample. This letter experimentally demonstrates the advantages of chirped modulation and introduces a thermophotonic modality of thermal-wave radar based on an emissivity-normalized, higher-dynamic-range contrast parameter known as cross-correlation phase. Finally, comparisons made on a biological (dental) sample show potential applications of the method.

10 October 2011 in Physical Review Letters
Verified
Journal Article
Closed access
NTNima Tabatabaei
Nima Tabatabaei
AMAndreas Mandelis
Andreas Mandelis
Energy transport in diffusion-wave fields is gradient-driven and therefore diffuse, yielding depth-integrated responses with poor axial resolution. Using matched-filter principles, we propose a methodology enabling these parabolic diffusion-wave energy fields to exhibit energy localization akin to propagating hyperbolic wave fields. This not only improves axial resolution but also allows for deconvolution of individual responses of superposed axially discrete sources, opening a new field of depth-resolved subsurface thermal coherence tomography using diffusion waves.

10 April 2018 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
NTNima Tabatabaei
Nima Tabatabaei
Kheibar DashtianKheibar Dashtian
Kheibar Dashtian
MGMehrorang Ghaedi
Mehrorang Ghaedi
MSMohammad Mehdi Sabzehmeidani
Mohammad Mehdi Sabzehmeidani
EAElham Ameri
Elham Ameri
The present work is devoted to the synthesis of two visible light-driven Cu-based metal organic frameworks composited with Ag 2 O nanoparticles.

13 December 2013 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
NTNima Tabatabaei
Nima Tabatabaei
DKDongKyun Kang
DongKyun Kang
TWTao Wu
Tao Wu
MKMinkyu Kim
Minkyu Kim
RCRobert W. Carruth
Robert W. Carruth
GTGuillermo J. Tearney
Guillermo J. Tearney
Eosinophilic esophagitis (EoE) is an allergic condition that is characterized by eosinophils infiltrating the esophageal wall. The treatment of the disease may require multiple follow up sedated endoscopies and biopsies to confirm elimination of eosinophils. These procedures are expensive, time consuming, and may be difficult for patients to tolerate. Here we report on the development of a confocal microscopy capsule for diagnosis and monitoring of EoE. The swallowable capsule implements a high-speed fiber-based reflectance confocal microscopy technique termed Spectrally Encoded Confocal Microscopy (SECM). SECM scans the sample in one dimension without moving parts by using wavelength swept source illumination and a diffraction grating at the back plane of the objective lens. As the wavelength of the source is tuned, the SECM optics within the 7 x 30 mm capsule are rotated using a driveshaft enclosed in a 0.8 mm flexible tether. A single rotation of the optics covered a field of view of 22 mm x 223 µm. The lateral and axial resolutions of the device were measured to be 2.1 and 14 µm, respectively. Images of Acetic Acid stained swine esophagus obtained with the capsule ex vivo and in vivo clearly showed squamous epithelial nuclei, which are smaller and less reflective than eosinophils. Imaging of esophageal biopsies from EoE patients ex vivo demonstrated the capability of this technology to visualize individual eosinophils. Based on the results of this study, we believe that this capsule will be a simpler and more effective device for diagnosing EoE and monitoring the therapeutic response of this disease.

1 January 2011 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
NTNima Tabatabaei
Nima Tabatabaei
AMAndreas Mandelis
Andreas Mandelis
BABennett Tochukwu Amaechi
Bennett Tochukwu Amaechi
As an extension of frequency-domain photothermal radiometry, a novel dental-imaging modality, thermophotonic lock-in imaging (TPLI), is introduced. This methodology uses photothermal wave principles and is capable of detecting early carious lesions and cracks on occlusal and approximal surfaces as well as early caries induced by artificial demineralizing solutions. The increased light scattering and absorption within early carious lesions increases the thermal-wave amplitude and shifts the thermal-wave centroid, producing contrast between the carious lesion and the intact enamel in both amplitude and phase images. Samples with artificial and natural occlusal and approximal caries were examined in this study. Thermophotonic effective detection depth is controlled by the modulation frequency according to the well-known concept of thermal diffusion length. TPLI phase images are emissivity normalized and therefore insensitive to the presence of stains. Amplitude images, on the other hand, provide integrated information from deeper enamel regions. It is concluded that the results of our noninvasive, noncontacting imaging methodology exhibit higher sensitivity to very early demineralization than dental radiographs and are in agreement with the destructive transverse microradiography mineral density profiles.