Electroanalysis was performed using a boron-doped diamond (BDD) electrode for the simultaneous detection of 2-heptyl-3-hydroxy-4-quinolone (PQS), 2-heptyl-4-hydroxyquinoline (HHQ) and pyocyanin (PYO). PQS and its precursor HHQ are two important signal molecules produced by Pseudomonas aeruginosa, while PYO is a redox active toxin involved in virulence and pathogenesis. This Gram-negative and opportunistic human pathogen is associated with a hospital-acquired infection particularly in patients with compromised immunity and is the primary cause of morbidity and mortality in cystic fibrosis (CF) patients. Early detection is crucial in the clinical management of this pathogen, with established infections entering a biofilm lifestyle that is refractory to conventional antibiotic therapies. Herein, a detection procedure was optimized and proven for the simultaneous detection of PYO, HHQ and PQS in standard mixtures, biological samples, and P. aeruginosa spiked CF sputum samples with remarkable sensitivity, down to nanomolar levels. Differential pulse voltammetry (DPV) scans were also applicable for monitoring the production of PYO, HHQ and PQS in P. aeruginosa PA14 over 8 h of cultivation. The simultaneous detection of these three compounds represents a molecular signature specific to this pathogen.
Nafion formed on the surface of a boron-doped diamond electrode allows for a chemosensing system for biotin. The modified electrode is capable of oxidizing biotin and offers a detection limit of 5 nM, the average normal level of biotin in blood plasma. The developed method was successfully applied to determine biotin in human plasma samples and a popular health product as two popular models.
18 December 2019 in Organic & Biomolecular Chemistry
The isoquinolinequinone (IQQ) pharmacophore is a privileged framework in known cytotoxic natural product families, caulibugulones and mansouramycins. Exploiting both families as a chemical starting point, we report on the structured development of an IQQ N-oxide anticancer framework which exhibits growth inhibition in the nM range across melanoma, ovarian and leukaemia cancer cell lines. A new lead compound (16, R6 = benzyl, R7 = H) exhibits nM GI50 values against 31/57 human tumour cell lines screened as part of the NCI60 panel and shows activity against doxorubicin resistant tumour cell lines. An electrochemical study highlights a correlation between electropositivity of the IQQ N-oxide framework and cytotoxicity. Adduct binding to sulfur based biological nucleophiles glutathione and cysteine was observed in vitro. This new framework possesses significant anticancer potential.
A capillary zone electrophoretic (CZE) method was developed, validated, and applied for the assay of metformin (MET) and pioglitazone (PIO) in pharmaceutical formulations. The optimum running buffer composition was found to be 75 mmol/L phosphate buffer containing 30% acetonitrile (ACN) at pH 4.0. The optimum instrumental conditions were found to be injection time, 10 s; applied voltage, 25 kV; hydrodynamic injection pressure, 0.5 psi for 10 s, capillary temperature, 25 °C; and the detection wavelength, 210 nm. The quantifications were calculated based on the ratio of the peak areas of analytes to atenolol as an internal standard. The CZE method was validated in terms of accuracy (98.21–104.81%), intra- and inter-day precision of migration time and peak area (relative standard deviation ≤ 5%), linearity (correlation coefficients ≥ 0.9985), limit of detection (≤0.277 μg/mL), and limit of quantitation (≤0.315 μg/mL). The proposed method was applied for the analysis of PIO and MET both individually and in a combined dosage tablet formulation. All electrophoretic parameters were calculated and evaluated. A previously reported high-performance liquid chromatographic (HPLC) method was also applied to the same samples. A comprehensive comparison was then carried out for the analytical features of both methods CZE and HPLC. Comparable results were obtained with the advantage of reagent consumption and separation efficiency of CZE over HPLC and shorter analysis time by HPLC compared with CZE.