Justyna Darmochwał-Podoba

Mrs. Justyna Darmochwał-Podoba

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2026 in Polityka Energetyczna – Energy Policy Journal
Verified
Journal Article
Open access
PDF file
JDJustyna Darmochwał-Podoba
Justyna Darmochwał-Podoba
Sławomir RabczakSławomir Rabczak
Sławomir Rabczak
In the context of the global increase in energy demand and the progressive depletion of fossil fuel resources, there is a noticeable intensification of efforts aimed at reducing the use of non-renewable raw materials in favor of developing and implementing technologies based on renewable energy...

10 October 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Ewelina BarnatEwelina Barnat
Ewelina Barnat
RSRobert Sekret
Robert Sekret
Sławomir RabczakSławomir Rabczak
Sławomir Rabczak
JDJustyna Darmochwał-Podoba
Justyna Darmochwał-Podoba
Climate change and rising temperatures in cities as a result of the Urban Heat Island (UHI) are increasing heat stress and forcing the development of efficient, sustainable outdoor cooling systems. The aim of this article was to analyse the integration of adiabatic air cooling systems with photovoltaic (PV) installations in the context of improving thermal comfort and energy autonomy. The study was carried out on the example of a bus station in Rzeszów (Poland), considering two variants of systems: indirect evaporative cooling (PKW/PV-CP-KW) and direct evaporative cooling (BKW/PV-CP-KW). Four levels of the upper limit of thermal comfort (TEmax = 22°C, 22.9°C, 24°C, 25°C) were considered to assess the impact of comfort parameters on the number of hours of system operation, energy consumption and operating costs. The results indicate that raising the TEmax reduces system uptime and significantly reduces the need for cooling – for example, increasing the TEmax from 22.9°C to 24°C reduces usable energy by 41%. At TEmax = 25°C, the BKW system achieves full energy autonomy, it is fully powered by PV. A Life Cycle Analysis (LCA) and Operating Cost of Ownership (LCC) confirmed the environmental and economic benefits of using higher TEmax values. The study highlights the potential of adiabatic cooling systems, in cooperation with a local PV installation, as an adaptive solution, improving thermal comfort in urban space with minimal grid energy consumption.

10 March 2026 in Civil and Environmental Engineering Reports
Verified
Journal Article
Open access
PDF file
JDJustyna Darmochwał-Podoba
Justyna Darmochwał-Podoba
Sławomir RabczakSławomir Rabczak
Sławomir Rabczak
In response to increasingly stringent European Union directives and national regulations on the energy performance of buildings, reliable and interpretable energy assessment methods are essential, particularly for public utility buildings due to their large floor areas and significant contribution to national energy demand. This study compares regulatory calculation results obtained for an administrative public utility building using two frameworks: the energy performance certificate (EPC) procedure and the energy audit methodology. The objective is to quantify methodological discrepancies and to indicate which model assumptions most strongly affect ventilation–related losses and the resulting energy indicators. For the investigated building, the ventilation heat loss coefficient determined within the audit methodology was 37% higher than that obtained under the EPC procedure, which translated into an over 31% higher useful energy demand for heating and ventilation. The audit–based EU and EK indicators were higher than those calculated within the EPC framework, while the EP indicator remained at a comparable level, indicating that differences in methodological assumptions can substantially alter the distribution of useful and final energy components without necessarily producing a proportional change in primary energy. The reported differences should be interpreted as consequences of distinct regulatory algorithms and input treatment (including ventilation and infiltration air flow rates and system efficiency assumptions) rather than as evidence of divergence from actual operational energy use, as measurement–based validation was not performed. The findings support a more cautions interpretation of EPC and audit outputs and underline the need for broader case samples and operational data to generalise results.

5 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
Ewelina BarnatEwelina Barnat
Ewelina Barnat
RSRobert Sekret
Robert Sekret
Sławomir RabczakSławomir Rabczak
Sławomir Rabczak
JDJustyna Darmochwał-Podoba
Justyna Darmochwał-Podoba
Climate change and rising temperatures in cities due to the urban heat island (UHI) effect are causing increased heat stress and driving the development of efficient, sustainable outdoor cooling systems. The aim of this article was to analyze the integration of adiabatic air cooling systems with photovoltaic (PV) installations in the context of improving thermal comfort and energy autonomy. The study was conducted on the example of a bus station in Rzeszow (Poland), considering two system variants: indirect evaporative cooling and direct evaporative cooling. To assess the impact of comfort parameters on the number of hours of system operation, energy consumption, and operating costs, four upper thermal comfort limits were considered: 22 °C, 22.9 °C, 24 °C, and 25 °C. The results indicate that increasing the upper limit of thermal comfort reduces the operating time of the system and significantly reduces the demand for cooling—for example, increasing the thermal comfort range from 22.9 °C to 24 °C reduces useful energy by 41%. Assuming a thermal comfort range of 25 °C, the direct evaporative cooling system achieves full energy autonomy and is fully powered by photovoltaics. Life cycle analysis (LCA) and life cycle cost (LCC) confirmed the environmental and economic benefits of using higher thermal comfort values. The study highlights the potential of adiabatic cooling systems, in conjunction with a local photovoltaic installation, as an adaptive solution that improves thermal comfort in urban spaces with minimal energy consumption from the grid.