Lonni R. Schultz

Dr. Lonni R. Schultz


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2015 in Neurocritical Care
Verified
Journal Article
Closed access
PDF file
SMSumul Modi
Sumul Modi
DDDevanshi Dharaiya
Devanshi Dharaiya
LSLonni R. Schultz
Lonni R. Schultz
PVPanayiotis Varelas
Panayiotis Varelas

1 August 2011 in Brain Research
Verified
Journal Article
Closed access
PLPeter LeWitt
Peter LeWitt
LSLonni R. Schultz
Lonni R. Schultz
PAPeggy Auinger
Peggy Auinger
MLMei Lu
Mei Lu

1 June 2002 in International Journal of Methods in Psychiatric Research
Verified
Journal Article
Closed access
PDF file
LSLonni R. Schultz
Lonni R. Schultz
EPEdward L. Peterson
Edward L. Peterson
NBNaomi Breslau
Naomi Breslau

1 January 2015 in Surgical Neurology International
Verified
Journal Article
Open access
KRKevin Reinard
Kevin Reinard
ABAzam Basheer
Azam Basheer
SPScott Phillips
Scott Phillips
ASAllison Snyder
Allison Snyder
AAAjay Agarwal
Ajay Agarwal
JSJasonM Schwalb
JasonM Schwalb
Recent studies have suggested that Evan's Index (EI) is not accurate and instead endorse volumetric measurements. Our aim was to evaluate the reproducibility of linear measurements and their correlation to ventricular volume. Using magnetic resonance (MR) images of 30 patients referred for normal pressure hydrocephalus (NPH), EI, frontal-occipital horn ratio (FOR), third ventricular width and height, frontal horn width (FHW), and callosal angle (CA) at the foramen of Monro and the posterior commissure (PC) were independently measured by residents in neurosurgery and radiology, a neurosurgeon and radiologist, and a medical student. Intraclass correlation coefficients (ICC) were calculated to establish inter-rater agreement among the reviewers. Pearson's correlation coefficients were done to assess the relationship of the linear measurements with total ventricular volume. Kappa analyses were performed to assess the degree of agreement between cutpoints determined by the ROC analysis for the linear measurements and reviewers' gestalt impression about ventricular size with volumetric abnormality. The overall inter-rater agreement among reviewers was almost perfect for EI (ICC = 0.913), FOR (ICC = 0.830), third ventricular width, FHW (ICC = 0.88), and CA at PC (ICC = 0.865), substantial for temporal horn width (ICC = 0.729) and CA at foramen of Monro (ICC = 0.779), and moderate for third ventricular height (ICC = 0.496). EI, FOR, third ventricular width, temporal horn width, and CA at PC measures correlated with total ventricular volume. There was fair-to-almost-perfect agreement of the individual reviewer's gestalt responses of abnormatility with volumetric abnormality. Gestalt responses were better for more senior raters. Linear measurements are reliable and reproducible methods for determining ventricular enlargement.

11 December 2009 in Fluids and Barriers of the CNS
Verified
Journal Article
Open access
PDF file
SKSatish Krishnamurthy
Satish Krishnamurthy
JLJie Li
Jie Li
LSLonni R. Schultz
Lonni R. Schultz
JMJames P McAllister
James P McAllister
Popular circulation theory of hydrocephalus assumes that the brain is impermeable to cerebrospinal fluid (CSF), and is therefore incapable of absorbing the CSF accumulating within the ventricles. However, the brain parenchyma is permeable to water due to the presence of specific ion channels as well as aquaporin channels. Thus, the movement of water into and out of the ventricles may be determined by the osmotic load of the CSF. If osmotic load determines the aqueous content of CSF in this manner, it is reasonable to hypothesize that hydrocephalus may be precipitated by pathologies and/or insults that produce sustained elevations of osmotic content within the ventricles.

24 November 2015 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
JKJoshua Kim
Joshua Kim
KGKim Garbarino
Kim Garbarino
LSLonni R. Schultz
Lonni R. Schultz
KLKenneth Levin
Kenneth Levin
BMBenjamin Movsas
Benjamin Movsas
CGCarri Glide-Hurst
Carri Glide-Hurst
Magnetic resonance imaging (MRI) has been incorporated as an adjunct to CT to take advantage of its excellent soft tissue contrast for contouring. MR-only treatment planning approaches have been developed to avoid errors introduced during the MR-CT registration process. The purpose of this study is to evaluate calculated dose distributions after incorporating a novel synthetic CT (synCT) derived from magnetic resonance simulation images into prostate cancer treatment planning and to compare dose distributions calculated using three previously published MR-only treatment planning methodologies. An IRB-approved retrospective study evaluated 15 prostate cancer patients that underwent IMRT (n = 11) or arc therapy (n = 4) to a total dose of 70.2-79.2 Gy. Original treatment plans were derived from CT simulation images (CT-SIM). T1-weighted, T2-weighted, and balanced turbo field echo images were acquired on a 1.0 T high field open MR simulator with patients immobilized in treatment position. Four MR-derived images were studied: bulk density assignment (10 HU) to water (MRW), bulk density assignments to water and bone with pelvic bone values derived either from literature (491 HU, MRW+B491) or from CT-SIM population average bone values (300 HU, MRW+B300), and synCTs. Plans were recalculated using fixed monitor units, plan dosimetry was evaluated, and local dose differences were characterized using gamma analysis (1 %/1 mm dose difference/distance to agreement). While synCT provided closest agreement to CT-SIM for D95, D99, and mean dose (<0.7 Gy (1 %)) compared to MRW, MRW+B491, and MRW+B300, pairwise comparisons showed differences were not significant (p < 0.05). Significant improvements were observed for synCT in the bladder, but not for rectum or penile bulb. SynCT gamma analysis pass rates (97.2 %) evaluated at 1 %/1 mm exceeded those from MRW (94.7 %), MRW+B300 (94.0 %), or MRW+B491 (90.4 %). One subject’s synCT gamma (1 %/1 mm) results (89.9 %) were lower than MRW (98.7 %) and MRW+B300 (96.7 %) due to increased rectal gas during MR-simulation that did not affect bulk density assignment-based calculations but was reflected in higher rectal doses for synCT. SynCT values provided closest dosimetric and gamma analysis agreement to CT-SIM compared to bulk density assignment-based CT surrogates. SynCTs may provide additional clinical value in treatment sites with greater air-to-soft tissue ratio.