Photoacoustic imaging is an emerging imaging modality that is based upon the photoacoustic effect. In photoacoustic tomography (PAT), the induced acoustic pressure waves are measured by an array of detectors and used to reconstruct an image of the initial pressure distribution. A common challenge faced in PAT is that the measured acoustic waves can only be sparsely sampled. Reconstructing sparsely sampled data using standard methods results in severe artifacts that obscure information within the image. We propose a modified convolutional neural network (CNN) architecture termed Fully Dense UNet (FD-UNet) for removing artifacts from 2D PAT images reconstructed from sparse data and compare the proposed CNN with the standard UNet in terms of reconstructed image quality.
Surface electromyography (sEMG) has been the predominant method for sensing electrical activity for a number of applications involving muscle-computer interfaces, including myoelectric control of prostheses and rehabilitation robots. Ultrasound imaging for sensing mechanical deformation of functional muscle compartments can overcome several limitations of sEMG, including the inability to differentiate between deep contiguous muscle compartments, low signal-to-noise ratio, and lack of a robust graded signal. The objective of this study was to evaluate the feasibility of real-time graded control using a computationally efficient method to differentiate between complex hand motions based on ultrasound imaging of forearm muscles. Dynamic ultrasound images of the forearm muscles were obtained from six able-bodied volunteers and analyzed to map muscle activity based on the deformation of the contracting muscles during different hand motions. Each participant performed 15 different hand motions, including digit flexion, different grips (i.e., power grasp and pinch grip), and grips in combination with wrist pronation. During the training phase, we generated a database of activity patterns corresponding to different hand motions for each participant. During the testing phase, novel activity patterns were classified using a nearest neighbor classification algorithm based on that database. The average classification accuracy was 91%. Real-time image-based control of a virtual hand showed an average classification accuracy of 92%. Our results demonstrate the feasibility of using ultrasound imaging as a robust muscle-computer interface. Potential clinical applications include control of multiarticulated prosthetic hands, stroke rehabilitation, and fundamental investigations of motor control and biomechanics.
28 August 2013 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Recently there have been major advances in the electro-mechanical design of upper extremity prosthetics. However, the development of control strategies for such prosthetics has lagged significantly behind. Conventional noninvasive myoelectric control strategies rely on the amplitude of electromyography (EMG) signals from flexor and extensor muscles in the forearm. Surface EMG has limited specificity for deep contiguous muscles because of cross talk and cannot reliably differentiate between individual digit and joint motions. We present a novel ultrasound imaging based control strategy for upper arm prosthetics that can overcome many of the limitations of myoelectric control. Real time ultrasound images of the forearm muscles were obtained using a wearable mechanically scanned single element ultrasound system, and analyzed to create maps of muscle activity based on changes in the ultrasound echogenicity of the muscle during contraction. Individual digit movements were associated with unique maps of activity. These maps were correlated with previously acquired training data to classify individual digit movements. Preliminary results using ten healthy volunteers demonstrated this approach could provide robust classification of individual finger movements with 98% accuracy (precision 96%-100% and recall 97%-100% for individual finger flexions). The change in ultrasound echogenicity was found to be proportional to the digit flexion speed (R2=0.9), and thus our proposed strategy provided a proportional signal that can be used for fine control. We anticipate that ultrasound imaging based control strategies could be a significant improvement over conventional myoelectric control of prosthetics.
1 October 2011 in Journal of Ultrasound in Medicine