Cold atmospheric plasma (CAP) is a promising alternative to antibiotics and chemical substances in dentistry that can reduce the risk of unwanted side effects and bacterial resistance. AmbiJet is a device that can ignite and deliver plasma directly to the site of action for maximum effectiveness. The aim of the study was to investigate its antimicrobial efficacy and the possible development of bacterial resistance. The antimicrobial effect of the plasma was tested under aerobic and anaerobic conditions on bacteria (five aerobic, three anaerobic (Gram +/−)) that are relevant in dentistry. The application times varied from 1 to 7 min. Possible bacterial resistance was evaluated by repeated plasma applications (10 times in 50 days). A possible increase in temperature was measured. Plasma effectively killed 106 seeded aerobic and anaerobic bacteria after an application time of 1 min per 10 mm2. Neither the development of resistance nor an increase in temperature above 40 °C was observed, so patient discomfort can be ruled out. The plasma treatment proved to be effective under anaerobic conditions, so the influence of ROS can be questioned. Our results show that AmbiJet efficiently eliminates pathogenic oral bacteria. Therefore, it can be advocated for clinical therapeutic use.
29 August 2007 in Plasma Chemistry and Plasma Processing
Objective: This study evaluated the effectiveness of a new cold atmospheric plasma device (AmbiJet) for eradicating mature oral biofilm on titanium implant surfaces, aiming to improve decontamination methods for the treatment of peri-implant infections. Material and methods: Mature oral biofilms were grown on titanium disks placed in participants’ mouths. These disks were divided into control and plasma treatment groups. The AmbiJet device delivered plasma directly to the implant surface for 3 min per 20 mm2, utilizing the applicator nozzle and implant as electrodes. Biofilm reduction was quantified by counting colony-forming units (CFUs). Results: Cold plasma treatment rendered approximately 90% of samples bacteria-free. A > 6-log10 reduction (≈99.9999%) in bacterial load was achieved in 30% of samples, with an overall average reduction of 4.9-log10 across all treated samples. The temperature during treatment remained below 40 °C. Conclusions: Within the study’s limitations, cold atmospheric plasma effectively eradicates mature oral biofilm on titanium surfaces. This high disinfection efficacy is likely due to the combined action of reactive species and electrical phenomena, which does not cause significant temperature increases.