Background: The prevalence of POP in women ranges from 30–40%, with 10–20% requiring surgical intervention. Annually, over 225,000 surgical procedures for POP are performed in the United States. The severity of prolapse is assessed using the four-stage POP-Q system, which facilitates clinical research by providing a standardized measure of defect severity. Surgical intervention is indicated for more severe cases, with various techniques available through vaginal or abdominal access. Synthetic meshes, primarily made of polypropylene (PP), are commonly used in POP surgeries due to their biocompatibility and mechanical support. This research aims to evaluate the effectiveness and safety of a non-resorbable, light polypropylene gynecological mesh (G-Mesh®, Tricomed S.A., Łódź, Poland) in the surgical treatment of pelvic floor prolapse in women. Methods: The meshes were implanted via laparoscopy (Dubuisson method) and laparotomy or transvaginally. A multicenter, retrospective study was conducted involving 81 patients aged 28–83. Results: The results collected at three follow-up visits indicated a high level of patient satisfaction, minimal discomfort, and no significant pain. Many patients emphasized significant improvement in quality of life and the lack of any adverse events associated with the presence of the implant. Conclusions: The G-Mesh® gynecological mesh has emerged as an effective and safe intervention for treating pelvic floor dysfunction in women, addressing conditions such as cystocele, rectocele, uterine prolapse, and ureterocele.
Background: The Codubix® ŻEBRA and Codubix® S ŻEBRA prostheses (by Tricomed SA), made of a biocompatible polypropylene–polyester braid, were developed as tools for the treatment of bone defects resulting from cancer surgery or mechanical injuries. Methods: The retrospective analysis investigation presents the efficacy and safety of rib bone prostheses made of knitted polyester–polypropylene fabric used to fill defects in the ribs and sternum. Data were collected from 113 patients (68 males, 45 females) undergoing surgery at three clinical centres. Prosthesis implantation was performed to bridge bone defects in the ribs and/or sternum. The analysis included preoperative and intraoperative data, two follow-up visits and a final interview with the patients. All prostheses were implanted using two techniques for filling defects in the chest wall: the ‘hammock’ (suspension) fixation method in 87 patients, and the ‘rigid’ fixation method in 26 patients. Results: The main cause of defects was cancer surgery (95.6%) performed in cases of sarcomas, squamous cell carcinomas, and desmoid tumours. Other causes (e.g., congenital defects and mechanical trauma) were less common. The ‘rigid’ fixation method extended the surgery time by approximately 16 min compared to the suspension method. Differences were also noted in the recovery period—an average of 56 days for the ‘hammock’ method and 30 days for the ‘rigid’ method. During the second follow-up visit, the treatment outcome using these prostheses was rated as good in 90.3% of cases. The average duration of hospitalisation was 21 days, regardless of the implantation method. No prosthesis-related adverse events were reported. Complications were observed in 21 cases in the first days after surgery. The most common ones were sensory disturbances (5.3%), infections (3.5%), haematomas and blood effusions (2.7%). Conclusions: A retrospective study demonstrates that knitted prostheses are safe and effective solution for repairing extensive defects resulting from tumours, trauma or congenital malformations. The implants ensure high patient comfort and maintain normal physical functioning without interference.