Charyl Yap

Ms. Charyl Yap

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2021 in Journal of Endovascular Therapy
Verified
Journal Article
Open access
PDF file
TTTjun Yip Tang
Tjun Yip Tang
CYCharyl Yap
Charyl Yap
SSShereen Xue Yun Soon
Shereen Xue Yun Soon
SCSze Ling Chan
Sze Ling Chan
QLQingWei Shaun Lee
QingWei Shaun Lee
TCTze Tec Chong
Tze Tec Chong
Purpose: The performance of sirolimus-coated devices has not been studied in patients with chronic limb-threatening ischemia patients. PRESTIGE aims to investigate the 6-month efficacy and safety profile of the Selution Sustained Limus Release (SLR) sirolimus-eluting balloon for treatment of TASC II C and D tibial occlusive lesions in patients with CLTI. Materials and Methods: PRESTIGE is a pilot prospective, nonrandomized, single-arm, multi-investigator, single-center clinical study. Endpoints were adverse event-free survival at 1 month, technical success rate, primary tibial patency at 6 months, limb salvage success, target lesion revascularization (TLR), and amputation free survival (AFS). Results: A total of 25 patients were included. There were 17 (68.0%) males; mean age, 63.7±9.73 years. CLTI severity was based on the Rutherford scale (R5=25/25; 100.0%). Significant comorbidities included diabetes mellitus (n=22; 88.0%) and end-stage renal failure (n=11; 44.0%). A total of 33 atherosclerotic lesions were treated (TASC II D=15 (45.5%)). Mean lesion length treated was 191±111 mm. Technical success was 100%. Primary tibial patency at 6 months was 22/27 (81.5%) and freedom from clinically driven TLR was 25/30 (83.3%). AFS was 21/25 (84.0%; 3 deaths and 1 major lower extremity amputation). Mean Rutherford score improved from 5.00 at baseline to 1.14±2.10 (p<0.05) at 6 months. There was a wound healing rate of 13/22 (59.1%) and 17/21 (81.0%) at 3 and 6 months respectively. Conclusions: Selution SLR drug-eluting balloon is a safe and efficacious modality in treating complex tibial arterial occlusive lesions in what is an otherwise frail cohort of CLTI patients, with a high prevalence of diabetes and end-stage renal failure. Technical and clinical success rates are high and 6-month target lesion patency and AFS are more than satisfactory.

11 June 2021 in Vascular Specialist International
Verified
Journal Article
Open access
PDF file
SSShereen X. Y. Soon
Shereen X. Y. Soon
APAnkur Patel
Ankur Patel
TCTze Tec Chong
Tze Tec Chong
CYCharyl Yap
Charyl Yap
HTHsien Ts'UNg Tay
Hsien Ts'UNg Tay
TTTjun Yip Tang
Tjun Yip Tang
Shereen X. Y. Soon, Ankur Patel, Tze Tec Chong, Charyl J. Q. Yap, Hsien Ts’ung Tay, Kiang Hiong Tay, Chandramohan Sivanathan, and Tjun Y. Tang. Vasc Specialist Int 2021;37:. https://doi.org/10.5758/vsi.210016

24 June 2022 in CVIR Endovascular
Verified
Journal Article
Open access
PDF file
YLY. L. Linn
Y. L. Linn
ECE. T. C. Choke
E. T. C. Choke
CYCharyl Yap
Charyl Yap
RTR. Y. Tan
R. Y. Tan
APA. Patel
A. Patel
TTTjun Yip Tang
Tjun Yip Tang
Sirolimus-coated balloons (SCB) have demonstrated much promise as an alternative drug eluting device to the existing paclitaxel coated balloon platforms for the treatment of peripheral arterial disease (PAD). They have been well tested pre-clinically and have demonstrated anti-restenotic effects as well as clinical safety in its use for treatment of coronary artery disease. The existing approved SCBs have thus far demonstrated good short-term patency (12-months) and did not exhibit any major adverse events or device related shortcomings in its use for treatment of PAD. There are several studies ongoing which aim to further investigate the efficacy of existing SCBs and establish a direct comparison of its outcomes compared with plain balloon angioplasty. Also, SCB utility to salvage failing arteriovenous fistulas for haemodialysis patients has also been explored. We review the current progress made in the establishment of SCB in the treatment of PAD as well as highlight ongoing studies investigating the role of SCB in various settings.

28 April 2022 in Phlebology: The Journal of Venous Disease
Verified
Journal Article
Closed access
TTTjun Yip Tang
Tjun Yip Tang
CYCharyl Yap
Charyl Yap
SCSze Ling Chan
Sze Ling Chan
SSShereen Xue Yun Soon
Shereen Xue Yun Soon
MLMervin Han Hui Lim
Mervin Han Hui Lim
JTJimmy Wei Hwa Tan
Jimmy Wei Hwa Tan
Introduction: Medium-term outcome data are lacking for dedicated venous stents especially from the Asian population. Objectives: Aim was to determine the 2-year patency and symptomatic relief gained from using the BD Venovo™ and Optimed Sinus Obliquus™venous stents for ilio-femoral obstruction (IFO). Methods: 60 patients (71 limbs; 39 females; mean age of 66.4 ± 11.9 years) were included in this prospective dual centre Asian cohort. Clinical improvement was determined by change in the CEAP, rVCSS and pain scores. Stent patency and stenosis were measured using area reduction on CTV and diameter reduction on Duplex ultrasound. Results: At 2 years, 65.7% showed ≥1 CEAP score improvement from baseline and rVCSS and pain scores remained low and sustained. 87.1% venous leg ulcers remained healed. Freedom from target lesion revascularisation was 94.3% and overall stent patency was 87.1%. There were no stent fractures or migration reported. Conclusion: Dedicated venous stents for IFO were associated with sustained clinical improvement and a high freedom from reintervention at 2 years in Asian patients.

3 July 2021 in The Journal of Vascular Access
Verified
Journal Article
Open access
PDF file
TTTjun Yip Tang
Tjun Yip Tang
TCTze-Tec Chong
Tze-Tec Chong
CYCharyl Yap
Charyl Yap
SSShereen Xue Yun Soon
Shereen Xue Yun Soon
SCSze Ling Chan
Sze Ling Chan
AFAloke V Finn
Aloke V Finn
The aim of this pilot clinical study is to evaluate the safety and efficacy of the Selution Sustained Limus Release (SLR)™ sirolimus-coated balloon (M.A. MedAlliance SA, Nyon, Switzerland) for improving the patency of failing arterio-venous fistulas (AVF) in hemodialysis patients. We also present herein a pre-clinical pharmacokinetic and safety evaluation of Selution™ to justify its first use in hemodialysis patients for endovascular access salvage. This is an investigator-initiated prospective single-center, non-blinded single-arm trial. Forty patients with clinically significant de novo or recurrent stenoses in a mature AVF circuit will be recruited. All stenotic lesions will be prepared with high pressure non-compliant conventional balloon angioplasty (CBA) prior to deployment of the Sustained-Release Selution™ sirolimus drug-eluting balloon. The primary efficacy endpoint is 6-month target lesion primary patency and the primary safety endpoint is freedom from localized or systemic serious adverse events through 30 days. Secondary endpoints of interest include technical and clinical success rates and circuit access patency at 3 and 6 months. Follow-up will occur for 2 years for those patients whose AVFs remain patent. Pharmacokinetic and histological animal safety studies performed with the Selution™ coating formulation showed prolonged arterial tissue retention of sirolimus with therapeutic levels up to 60 days and non-toxic and rapidly declining blood levels. Histological results in animal models demonstrated safety, freedom from intraluminal thrombus, reduction in restenosis by sirolimus elution compared to CBA, and no evidence of embolic phenomena indicative of adverse particulate effects. Long release sirolimus coated balloons may serve as a promising novel alternative therapy to paclitaxel-based technology for treating conduit stenosis secondary to neointimal hyperplasia. Pre-clinical pharmacokinetic and histological animal data are encouraging and provide suggestion of safety and efficacy in this setting. This single-center trial will provide a first step toward demonstration of efficacy and safety of this device for treatment of stenotic fistulas.

30 December 2021 in The Journal of Vascular Access
Verified
Journal Article
Open access
PDF file
TTTjun Yip Tang
Tjun Yip Tang
SSShereen Xy Soon
Shereen Xy Soon
CYCharyl Yap
Charyl Yap
RTRu Yu Tan
Ru Yu Tan
SPSuh Chien Pang
Suh Chien Pang
TCTze Tec Chong
Tze Tec Chong
Aim of this pilot clinical study was to evaluate the safety and efficacy of the Selution Sustained Limus Release (SLR)™ sirolimus-eluting balloon (SEB) for improving failing arterio-venous fistulas (AVF) patency in Asian haemodialysis patients. Prospective single-centre, multi-investigator, non-consecutive, non-blinded single arm trial. Forty end-stage renal failure Asian patients with a dysfunctional AVF underwent SEB angioplasty between May and November 2020. All stenotic lesions were prepared with high pressure non-compliant balloon angioplasty prior to SEB angioplasty. Endpoints of interest included target lesion primary patency and circuit access patency and safety through 30 days. All patients received dual antiplatelet therapy for 1 month and were followed up with Duplex ultrasound at 6 months. There was one subject dropout so final n = 39 patients (mean age 65.0 ± 11.9; males = 26 (66.7%)) and n = 43 target lesions treated. Main indication for intervention was dropping access flow (24/39; 61.5%) and most common target lesion was in the juxta-anastomosis (24/43; 54.5%). There was 100% technical and procedural success. There were no adverse events related to the SEB. Target lesion primary patency rates at 3 and 6 months were 39/41 (95.1%) and 28/39 (71.8%) respectively. Access circuit patency rates at 3 and 6 months were 35/37 (94.6%) and 22/35 (62.9%) respectively. There were 3 (7.7%) deaths all attributable to patients’ underlying co-morbidities. Fistuloplasty using the novel Selution SLR™ SEB for dysfunctional AVF circuits seems a safe and effective modality in Asian haemodialysis patients at 6 months but larger randomised controlled studies are required now to determine its true efficacy against plain balloon angioplasty.