Although a substantial body of literature has explored the relationship between sleep and exercise, comprehensive reviews and definitive conclusions about the impact of exercise interventions on sleep are lacking. Electronic databases were searched for articles published between January 2013 and March 2017. Studies were included if they possessed either objective or subjective measures of sleep and an exercise intervention that followed the guidelines recommended by the American College of Sports Medicine. Thirty-four studies met these inclusion criteria. Twenty-nine studies concluded that exercise improved sleep quality or duration; however, four found no difference and one reported a negative impact of exercise on sleep. Study results varied most significantly due to participants’ age, health status, and the mode and intensity of exercise intervention. Mixed findings were reported for children, adolescents, and young adults. Interventions conducted with middle-aged and elderly adults reported more robust results. In these cases, exercise promoted increased sleep efficiency and duration regardless of the mode and intensity of activity, especially in populations suffering from disease. Our review suggests that sleep and exercise exert substantial positive effects on one another; however, to reach a true consensus, the mechanisms behind these observations must first be elucidated.
1 January 2016 in Journal of Physical Therapy Science
[Purpose] To determine the intra- and inter-rater agreement of a mobile application, PostureScreen Mobile® (PSM), that assesses static standing posture. [Subjects and Methods] Three examiners with different levels of experience of assessing posture, one licensed physical therapist and two untrained undergraduate students, performed repeated postural assessments of 10 subjects, fully clothed or minimally clothed, using PSM on two nonconsecutive days. Anterior and right lateral images were captured and seventeen landmarks were identified on them. Intraclass correlation coefficients (ICCs) were calculated for each of 13 postural measures to evaluate inter-rater agreement on the first visit (fully or minimally clothed), as well as intra-rater agreement between the first and second visits (minimally clothed). [Results] Eleven postural measures were ultimately analyzed for inter- and intra-rater agreement. Inter-rater agreement was almost perfect (ICC≥0.81) for four measures and substantial (0.60
1 August 2020 in International Journal of Chronic Obstructive Pulmonary Disease
Background: COPD exacerbations occur more frequently with disease progression and are associated with worse prognosis and higher healthcare expenditure. Purpose: To utilize a networked system, optimized with statistical process control (SPC), for remote patient monitoring (RPM) and to identify potential predictors of COPD exacerbations. Methods: Seventeen subjects, mean (SD) age of 69.7 (7.2) years, with moderate to severe COPD received RPM. Over 2618 patient-days (7.17 patient-years) of monitoring, we obtained daily symptom scores, treatment adherence, self-reported activity levels, daily spirometry (SVC, FEV1, FVC, PEF), inspiratory capacity (IC), and oxygenation (SpO2). These data were used to identify predictors of exacerbations defined using Anthonisen and other criteria. Results: After implementation of SPC, concordance analysis showed substantial agreement between FVC (decrease below the 7-day rolling average minus 1.645 SD) and self-reported healthcare utilization events (κ=0.747, P< 0.001) as well as between increased use of inhaled short-acting bronchodilators and exacerbations defined by two Anthonisen criteria (κ=0.611, P< 0.001) or modified Anthonisen criteria (κ=0.622, P< 0.001). There was a moderate agreement between FEV1 (decrease > 1.645 SD below the 7-day rolling average) and self-reported healthcare utilization events (κ=0.475, P< 0.001) and between SpO2 less than 90% and exacerbations defined by two Anthonisen criteria (κ=0.474, P< 0.001) or modified Anthonisen criteria (κ=0.564, P< 0.001). Conclusion: Exacerbations were best predicted by FVC and FEV1 below the one-sided 95% confidence interval derived from SPC but also by increased use of inhaled short-acting bronchodilators and fall in oxygen saturation. An RPM program that captures these parameters may be used to guide appropriate interventions aimed at reducing healthcare utilization in COPD patients.
Objectives: To characterize the continuity and duration of sleep, and to measure nocturnal cardiac autonomic balance via heart rate variability (HRV) in a group of emergency medical technicians (EMTs) on and off duty. Methods: Fourteen EMTs completed an online, daily sleep log that recorded total sleep duration, bedtime, rise time, and the number of alarms that caused awakening. HRV was captured using a physiological status monitor (PSM) affixed to a chest strap during sleep. Results: For the 7-day trial, each of the 14 EMTs logged three work days (WDs) and four non-work days (NWDs). They reported sleeping significantly fewer hours per night on WDs (6.4 ± 2.1) than on NWDs (7.9 ± 0.5; P < 0.05), and experienced more sleep disruptions on WDs (4.4 ± 2.8) than on NWDs (1.3 ± 2.2; P < 0.001) as measured by the number of alarms. Global and vagal indices of HRV during sleep were significantly reduced during WDs (Standard Deviation of Normal R-R Intervals (SDNN) = 43.4 ± 2.0 ms and High Frequency (HF) = 24.3 ± 1.2 ms2) when compared to NWDs (SDNN = 61.1 ± 1.0 ms and HF = 42.7 ± 1.5 ms2; P < 0.001). Conclusion: EMTs who worked 24-hour shifts had shorter, more fragmented sleep associated with greater cumulative exposure to increased sympathetic and decreased parasympathetic activity as measured via sleep HRV. These changes in cardiac autonomic tone constitute one plausible pathway through which sleep deprivation may increase risk for cardiovascular disease.
Determining body composition via mobile application may circumvent limitations of conventional methods. However, the accuracy of many technologies remains unknown. This investigation assessed the convergent and concurrent validity of a mobile application (LS) that employs 2-dimensional digital photography (LS2D) and 3-dimensional photonic scanning (LS3D). Measures of body composition including circumferences, waist-to-hip ratio (WHR), and body fat percentage (BF%) were obtained from 240 healthy adults using LS and a diverse set of conventional methods—Gulick tape, bioelectrical impedance analysis (BIA), and skinfolds. Convergent validity was consistently high—indicating these methods vary proportionally and can thus reliably detect changes despite individual measurement differences. The span of the Limits of Agreement (LoA) using LS were comparable to the LoA between conventional methods. LS3D exhibited high agreement relative to Gulick tape in the measurement of WHR, despite poor agreement with individual waist and hip circumferences. In BF%, LS2D exhibited high agreement with BIA and skinfold methods, whereas LS3D demonstrated low agreement. Interestingly, the low inferred bias between LS3D and DXA using existing data suggests that LS3D may have high agreement with dual-energy x-ray absorptiometry. Overall, the suitability of LS2D and LS3D to replace conventional methods must be based on an individual user’s criteria.
16 October 2017 in Advances in Preventive Medicine